Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso Heat & Glo LifeStyle, Modello COSMO-I35

Produttore : Heat & Glo LifeStyle
File Size : 2.27 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


A. Minimum Fireplace Opening Minimum fi replace opening requirements for a standard 3/4 inch deep surround are shown in Figure 5.1. For smaller openings, an optional 1-1/2 inch deep surround is available and dimensions are shown in Figure 5.2. WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access. Due to high temperatures, the appliance should be located out of traffi c and away from furniture and draperies. • The fi rebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a factory built fi rebox in order to gain minimum gas insert opening requirements. • Any smoke shelves, shields and baffl es may be removed from the factory built fi rebox if attached with mechanical fasteners. • The metal fl oor of the solid fuel fi rebox may be removed to facilitate the installation of the insert. The appliance may not be placed directly on the base of the outer wrap, a 1/4 inch airspace must be provided between the insert and the fl oor of the outer wrap. Use the levelling legs to raise the insert a minimum of 1/4 inch. The original fi replace may never be returned to solid fuel in this condition. The sidewalls and top structure of the fi rebox may not be altered with the exception of removable baffl es and dampers. • Cutting of any sheet metal parts of the fi replace in which the gas fi replace insert is to be installed is prohibited, except the fl oor as tested for and as noted above. TOP VIEW FRONT VIEW **Unit depth is measured to the back of the surround to give the depth needed for installation. SIDE VIEW 18 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev. H • 1/11 B. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specifi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc). Clearance to combustible material under the insert is 1/4 inch (6 mm). Clearance from top of fi replace opening for combustibles extending 12 inches max. is 12 inches. • Use leveling legs to raise insert minimum 1/4 inch (6 mm) above combustible material or outer wrap of factory built fi rebox. Combustible facings must not extend behind the insert surround. For non-combustible material specifi cations refer to section 1.E. Figure 5.3 Mantel Clearances 12 IN. MIN. 12 IN. MAX. EXISTING NON-COMBUSTIBLE FACING Figure 5.2 Fireplace Opening - Deep Surround CD SURROUND APPLIANCE 1-1/2 IN. BD AD SURROUND APPLIANCE MINIMUM FIREPLACE SIZE Location COSMO-I35 COSMO-I30 Inches Millimeters Inches Millimeters AD Alternate Unit Width 33-3/16 843 29-1/16 738 BD Alternate Unit Depth 15-1/16 383 13-7/8 352 CD Alternate Unit Height 22-9/16 573 19-1/16 484 * Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum fi replace height for bends in vent pipe. SIDE VIEW TOP VIEW 6 66 Termination Locations A. Vent Termination Minimum Clearances WARNING Fire Risk. Maintain vent clearance to combustibles as specified. • DO NOT pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause fire. HORIZONTAL OVERHANG VERTICAL WALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCH IS X/ 12 LOWEST DISCHARGE OPENING 2 FT. MIN. 20 INCHES MIN. H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Figure 6.2 Staggered Termination Caps Gas, Wood or Fuel Oil Termination Cap B Gas Termination Cap ** A * *If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instructions supplied with the decorative cap cover. ** AB6 in. (minimum) up to 20 in. 152 mm/508 mm 18 in. minimum 457 mm 20 in. and over 0 in. minimum In a staggered installation with both gas and wood or fuel oil terminations, the wood or fuel oil termination cap must be higher than the gas termination cap Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12.................................................1.25* Over 7/12 to 8/12.................................................1.5* Over 8/12 to 9/12.................................................2.0* Over 9/12 to 10/12...............................................2.5 Over 10/12 to 11/12.............................................3.25 Over 11/12 to 12/12.............................................4.0 Over 12/12 to 14/12.............................................5.0 Over 14/12 to 16/12.............................................6.0 Over 16/12 to 18/12.............................................7.0 Over 18/12 to 20/12.............................................7.5 Over 20/12 to 21/12.............................................8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev. H • 1/11 7 77 Inst...

Questo manuale è adatto anche per i modelli :
scaldabagno - COSMO-I30 (2.27 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie