Log:
valutazioni - 1, GPA: 4 ( )

Istruzioni per l'uso Kenmore, Modello 625.384600

Produttore : Kenmore
File Size : 369.2 kb
File Nome : 89dcbb10-9f2a-4f05-bb57-1d7acbd3c036.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


If you have questions when installing and us ing your drinking water filter system, call this toll-free number... 1 -800 -426 -9345 SAVE THIS MANUAL UNDERSINK DRINKING WATER FILTER SYSTEM • Safety Guides • Installation • Operation • Cartridge Replacement • Repair Parts ! System tested and certified by NSF International to | /'Lm_r'_ ANSI/NSF Standard 42 and 53 for the reduction of the claims specified on the performance data sheet. Sears, Roebuck and Co., Hoffman Estates, IL 60179 USA SAFETY GUIDES / SPECIFICATIONS • Read all steps and guides carefully before installing and using your undersink drinking water filter system. Follow all steps exactly to correctly install. Reading this manual will also help you to get all the benefits from the undersink drinking water filter system. • Do not use with water that is microbiologicaUy unsafe or of unknown quality without adequate disinfectionbefore or after the system. This system is certified for cyst reduction and may be used on disinfected waters that may contain filterable cysts. • Check with your local public works department for plumbing and sanitation codes. You must follow their guides as you install the system. Follow your local codes if they differ with guides in this manual. In Massachusetts, plumbing codes of Min. -Max. Supply Water Pressure Min. -Max. Supply Water Temperature Inlet -Outlet Massachusetts shall be adhered to. Consult with your licensed plumber. • The undersink drinking water filter system works on water pressures of 40 psi (minimum) to 100 psi (maximum). If your house water pressure is over the maximum, install a pressure reducing valve in the water supply pipe to the filter system. • Do not install the undersink drinking water filter system outside, or in extreme hot or cold temperatures. Temperature of the water supply to the under- sink drinking water filter system must be between 40°F and 100°F. Do not install on hot water. • Read the other limits (pH, hardness, etc.) in the specifications and be sure your water supply conforms. 40-100psi 40 -100 °F 3/8" NPT, fittings and tubing included WARRANTY FULL ONE YEAR WARRANTY ON UNDERSINK DRINKING WATER FILTER SYSTEM For one year from the date of purchase, Sears will replace this Undersink Drinking Water Filter System (except filter cartridges, which are purchased separately), free of charge, if defective in material or workmanship. WARRANTY IS AVAILABLE BY SIMPLY RETURNING THE UNDERSINK DRINKING WATER FILTER SYSTEM TO THE NEAREST SEARS STORE THROUGHOUT THE UNITED STATES. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Sears, Roebuck and Co., DEPT. 817 WA, Hoffman Estates, IL 60179 2 TABLE OF CONTENTS Parts of the System / Typical Installation Drawing / Tools Materials Needed ................................................ Drinking Water Filter System Installation ........................... Installing Supply Fitting ..................................... Installing Faucet ............................................ Installing Filter Cartridge .................................... Using the Filtered Water System ................................... Filter Cartridge Life / Replacement ................................. Repair Parts ................................................... and 4 5 -7 5 56 7 8 8 -9 10 -11 Locate the water the cold drinking filter housing water. Refer on to the the cold water following supply drawing. pipe, under the kitchen and / or bathroom sink, to filter FILTERING WATER TO ONE FAUCET kitchen sink t i filtered water faucet _ DRINKING WATER HOT COLD FILTER SYSTEM FILTER I FILTER II 3 PARTS OF THE SYSTEM MATERIALS AND TOOLS NEEDED filter system assembly including mounting bracket and screws water supply fitting _" filtered water faucet for sink or countertop mounting 3/8" tubing to make all needed connections TYPICAL UNDERSINK FIG. 1 faucet filtered water supply fitting shutoff valve \ Note: To change the fil ter cartridge, you must turn off the water and re-\ tease pressure by open ing the faucet. A nearby shutoff valve is conve* nient. Most sinks al ready have shutoff valves on the supply pipes. \ • plumbers putty • slotted and Phillips screwdrivers • pliers and adjustable jaw wrench • tubing cutter • sandpaper or emery cloth • electric driU and 3 / 4" d_l bit if mounting hole is needed for the faucet, see page 6 CAUTION: To avoid damaging the sink, consult a qualified plumber or installer for dialing procedures in porcelain or stainless steel. INSTALLATION WATER IN mounting screw (2) Filter II $ Filter I Note: Be sure to allowa minimumspaceof 1-1/2" under the system for removing the sump& to change the cartridges. 4 INSTALLATION STEPS STEP 1 -COLD WATER SUPPLY FITTING Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. The fitting must provide a leak-tight connection to the water filter 3 / 8" tubing. A typical connection using the included water suppl...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie