Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso NuTone, Modello CV450

Produttore : NuTone
File Size : 2.31 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Tools are handsome European styling in black CK230 DELUXE TOOL SET CK120 STANDARD TOOL SET Floor/Rug Tool has front and Floor/Rug Tool has dual wheels rear wheels to move smoothly for smooth performance and across surfaces. Includes even air flow. Two chrome steel Ratcheting Wand for added wands included. Brushes are convenience. Brushes are nylon bristles. Cloth tool natural fiber. Crevice tool is storage bag included. notched to provide continuous air flow. Cloth tool storage bag included. CT330B TURBINE CA130 HOSE SOCK STAIR TOOL Protects furniture, walls Easy to handle, hand- and woodwork. Fits all held stair brush, perfect 30' - 32' central CT155B HARD CT143B UNIVERSAL for deep cleaning cars, cleaning hoses, FLOOR TOOL DUSTING BRUSH steps, and tight places. 11.4" - 13.8" in diameter. 113.4" brush efficiently Versatile elongated Durable ABS plastic Purchase hose cleans hardwood dusting brush will housing, covered belt. separately. flooring, tile and other change the way you CT109B PET BRUSH hard floor surfaces. Two dust. Great for desks, (Shown at right) Nylon bristles rows of soft bristles, bookshelves, blinds, etc. for gentle grooming. dual wheels, and swivel Soft nylon bristles. Removable bristles for easy neck. cleaning. CK110 BASIC TOOL SET Floor/Rug Tool moves from floor to carpet with single pedal operation. Two durable ABS plastic wands included. Brushes are nylon bristles. 8 CLEANING FILTER A secondary safety located between provides protection bag should accidentally This filter should be checked if necessary, when replacement bags If the filter is excessively soiled, before replacing. IMPORTANT: Operation of the Power Unit without filter installed will void the warranty. REMOVING FILTER Remove lower receptacle and disposable bag. Using tab on edge of filter, pull and loosen filter from canister wall. Then, carefully pull filter off of bag adapter. REPLACING FILTER Make sure the filter is installed so that the pull tab is on the outside and accessible for future filter removal. Align hole in center of filter with opening in the middle of the bag adapter. Press filter upward until center hole locks over lugs on bag adapter. Press filters outer edge until it is secure against rib inside canister. Figure 1 Figure 2 5 TROUBLESHOOTING Read Before CenteRead Before Inlet switch Exhaust guard Trouble Possible Cause Possible Remedy 1. Loss or decrease of vacuum occurs. 1a. Disposable bag filled. 1a. Remove disposable bag and replacement. Note: Check secondary filter for possible dust accumulation and wash to clean 1b. Obstruction in the hose. A blockage 1b. Disconnect the hose from the wall Inlet in the hose can be determined by insert a blunt instrument into the hose – slightly inserting the hose into any Wall Inlet smaller in diameter – such as a flexible garden and, while Power Unit is running, hose. Push the garden hose through the check each additional inlet for cleaning system hose until the obstruction has normal suction by holding the palm been cleared. Mounting of your hand over the open inlet. If bracket normal suction is felt at all other inlets, insert the hose into a secondNuTone inlet. If the blockage still exists it is Exhaust and located in the hose. However, if the exhaust blockage does not occur when the coupling hose is changed, the blockage is probably located in the tubing Intake and system leading to the original inlet. 1c. Obstruction in the tubing system 1c. Insert hose end into any inlet with Power Unit NUTONE MODEL CV-352 SHOWN. YOUR ACTUAL UNIT MAY VARY IN APPEARANCE. intake coupling Polarized 3-pronged plug Gasket Canister latch 6-gallon disposable soil bagSecondary safety filterBag adapter Inlet inside the walls. running, place the palm of your hand over the opposite end of the hose. When you can feel the suction increase, hold your hand over the hose end for a few seconds and then quickly remove your hand. This procedure repeated several time should clear the obstruction. If the blockage is not cleared, service will be necessary. 1d. Wall Inlet cover not properly sealed. 1d. Check all Wall Inlet covers to be sure they are closed and sealed tightly. 2. Power unit does not start. 2a. Defective inlet. Check other Wall Inlets. 2a. Replace defective Wall Inlet. 2b. Thermoprotector has been activated. 2b. Check the overload protector button located on the front of the Power Unit. (Push to reset system. 2c. Blown fuse or tripped circuit breaker. 2c. Replace fuse or reset circuit breaker. 3. Power unit fails to stop when the hose is removed. 3a. An electrical short has occurred somewhere in the system. 3a. A complete check of all Wall Inlet and Power Unit low voltage control lead connections (external yellow leads). Turn system off by removing fuse or tripping circuit breaker at house fuse box. 67 ...

Questo manuale è adatto anche per i modelli :
Depuratori d - CV353 (2.31 mb)
Depuratori d - CV350 (2.31 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie