Log:
valutazioni - 2, GPA: 3 ( )

Istruzioni per l'uso GE, Modello GXSF31E

Produttore : GE
File Size : 1.15 mb
File Nome : 94d99580-b4cd-4939-87ca-93fe4cd8db6c.pdf
Lingua di insegnamento: enes
Vai a scaricare



Facilità d'uso


If the cabinet (brine tank) should over-fill with water, the excess is carried to the drain. 6. INSTALL GROUNDING CLAMP DANGER: Failure to properly attach ground clamp could result in electrical shock. Overflowdrain hoseGrommet Hose adapter If plumbing is metal, to maintain electrical ground continuity in the house cold water piping, Hose clamp install the included ground clamp as shown in Fig. 6. • Clean pipe with emery paper in the area where the clamp is to be installed. • Install grounding clamps as shown, making sure clamps fit freely around pipe. Do not connect to • Make sure lock washer is in place. valve drain hose. • Handtighten screw, then one more full turn with screwdriver. NOTE: When replacing an existing softener, also replace grounding clamps. If removing softener completely, hard-plumb the water line with same type of pipes as the To sewer drain original to assure plumbing integrity and ground continuity over the life of the home. 7. FLUSH PIPES, EXPEL AIR FROM SOFTENER AND TEST YOUR INSTALLATION FOR To valve inlet WATER LEAKS CAUTION: To avoid water or air pressure damage to softener inner parts, be sure to do the following steps in exact order. • Fully open 2 cold soft water faucets nearby the softener. • Place bypass valve in “bypass” position by pushing the stem inward. • Fully open the house main water pipe shutoff valve. Observe a steady flow from both faucets opened in step A, above. • Place bypass valve in the “service” position EXACTLY as follows. KEEP SOFT WATER FAUCETS OPEN. SLOWLY pull or slide the valve stem (out) toward the service position, pausing several times to allow the softener to pressurize slowly. • After about 3 minutes, open a HOT water faucet for 1 minute, or until all air is expelled, then close. NOTE: If water appears cloudy or has salty taste, allow to run for several more minutes, or until clear. • Close all water faucets. • Check your plumbing work for leaks and fix right away if any are found. Be sure to observe previous caution notes. • Turn on the gas or electric supply to the water heater. Light the pilot, if applicable. Fig. 6 Ground Clamp From valve outlet 8. ADD WATER AND SALT TO THE BRINE TANK • Lift the salt hole cover. Add about 3 gallons of water into the tank. Do not add into the brinewell. • Fill tank with NUGGET, PELLET or coarse SOLAR water softener salt with a purity of 99.5% or higher. Do not use rock, block, granulated and ice cream-making salts, or salt with iron-removing additives (except for Diamond Crystal® Red•Out® brand salt). Maximum salt storage capacity is approximately 200 lbs. Keep the salt hole cover closed unless servicing the unit or refilling with salt. NOTE: If the softener is installed in a humid basement or other damp area, it is better to fill the tank with less salt, more frequently. Eighty to 100 lbs. of salt will last for several months, depending on water hardness, family size and water softening system model. 9. CONNECT TO ELECTRICAL POWER • If transformer wiring is not visible at the back of the control head, remove control cover. DO NOT PULL ON OR DISCONNECT WIRING. Locate the long wire with “U” shaped connectors on one end. Route this wire through the rear of the control housing. • Fasten the 2 power cable lugs (“U” shaped connectors) to the 2 screws on the transformer, and tighten the screws. Then, plug the transformer into the electrical outlet. • The softener works on 24 volt-60Hz electric power. The included transformer changes standard 120-volt AC house power to 24 volts. Plug the transformer into a 120-volt outlet only. Be sure the outlet is always live so it can not be switched off by mistake. • Replace the control cover. Step-by-step installation instructions. Programming the Control CONTROL SETTINGS REQUIRED upon installation and after an extended power outage. NOTES: WHEN THE TRANSFORMER IS PLUGGED INTO THE ELECTRICAL OUTLET, 12:00 PM (flashing), and PRESENT TIME is displayed. Program the control as instructed below. If -- - is flashing, use the UP button to set the correct model code as follows: SR22 for GXSF27E or F31 for GXSF31E. If you pass by the correct code number, use the DOWN button. Then press the MODE button to accept the correct model. A “beep” sounds while pressing buttons for control programming. One beep signals a change in the control display. Repeated beeps mean the control will not accept a change from the button you have pressed, and you should select another button. To program the control, you will use the UP , DOWN and MODE buttons. Use the MODE button to select the desired control function. SET PRESENT TIME OF DAY 1. Press the MODE button until PRESENT TIME appears in the display. 2. Press UP or DOWN button to set. The UP button advances the time; the DOWN button moves the time in reverse. If the present time is between noon and midnight, be sure PM shows in the display. If the present time is between midnight and noon, be sure AM shows in the display. NOTE: Each press of an UP or ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie