Log:
valutazioni - 4, GPA: 3.5 ( )

Istruzioni per l'uso Sunbeam, Modello 2585

Produttore : Sunbeam
File Size : 435.6 kb
File Nome : a5644bf3-96ed-4724-9029-898faa706b99.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Your SUNBEAM electronic air cleaner has been designed to let you enjoy a refresh ing experience in clean air living. Polluted air enters the air cleaner through the front (Figure 1). The aluminum pre-filter 1 (Figure 2) on the inside of the front grill of the unit will help remove some of the large particles of pollution as dirty air is drawn in. Once inside the unit, the pollution particles inthe dirty air receive a powerful positive electrical charge as they pass through the ionizing section 2 The positive charged particles then enter a collecting section 3 with alternately charged positive and negative (ground) plates. The particles are repelled from the positive plates and attracted to the oppositely charged plates and remain there through natural adhesion until removed by the washing process. The air then passes through a charcoal filter 4 that helps remove household odors. Next the electronically cleaned air passes back into the room through the top grill. INSTRUCTIONS A. Remove plastic bag covering the air cleaner. B. Select location for air cleaner with electrical outlet nearby. Remember, air cleaner must be placed so there is unobstructed free circulation of air into and out of the unit. OPERATION A. Plug the power cord into any standard household electrical outlet. (See data label on bottom of unit for electrical specifications and power consumption. B. Turn unit on by turning the On/Off switch to the desired blower speed. (Low, Medium or High) (See Figure 3). Until your unit is adequately broken in, blower motor speed should be set on High for one minute initially before switching to desired setting. Your electronic air cleaner is designed for continuous operation . . . peak efficiency is obtained if the air cleaner remains on constantly. Figure 1 4. OPTIONAL CHARCOAL 1. PRE-FILTER, 2. ION!ZER 3. COLLECTOR AFTER-FILTER Figure 2 This appliance has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. Figure 3 NOTE: You may notice an occasional, infrequent sharp snapping sound coming from the unit. This is a normal occurrence called “arcing” and results as large particles of dust are collected in the collecting cell. Should prolonged or continuous arcing occur, the ionizing-collecting cell should be thoroughly cleaned and dried. (See Cleaning Instructions). CARE OF CABINET CABINET: You should treat the cabinet of your air cleaner as you would any other piece of fine furniture. Soft cloths and furniture polish will keep it clean and attractive for many years. OZONE Under normal operating conditions all electrostatic air cleaners produce minute quantities of ozone as an incidental by-product, as do televisions and other electrical appliances. Scientific measurements taken with the most accurate equipment available show the range of ozone emitted from a Sunbeam electronic air cleaner is between and ppm. This is between l/20 and l/5 of the established safe limits of 0.1 ppm. It is a negligible figure, in fact, if this amount of ozone is considered to be harmful, it is dangerous to take an afternoon walk in the park on a summer day. TO REMOVE CELL FOR CLEANING Cell will need cleaning about every four to eight weeks when air cleaner is in constant use. A. Turn off unit and unplug from electrical power source. B. Remove cabinet top. Cabinet top is easily removed by pressing down on tab located on top of front grill (Fig. 4); while pressing down on tab with one hand, slide cabinet top with other hand slowly toward front grill about one inch until unlocked. Cabinet top can now be lifted up and off. Figure 4 C. Push cell locking latch (Figure 5) away from cell while lifting cell out of the cabinet using the two small handles on the top of the cell (Figure 6). Figure 6 D. Slide pre-filter upward from front of cell (Figure 7). CELL HANDLE CELL LOCKING LATCH Figure 5 Figure 7 2 E. Slide charcoal filter upward from back of cell D. After the cell has soaked sufficiently, it should be (Figure 8). shaken vigorously in water until clean. (Figure 9). Figure 8 REPLACEMENT OF CHARCOAL FILTER ACTIVATED CHARCOAL FILTER HELPS REMOVE HOUSEHOLD ODORS: Washing the charcoal filter with soap and water will destroy its ability to adsorb odor. However, lint and dirt build-up can be removed with a vacuum cleaner using a brush attachment. Odor adsorption effectiveness will gradually deteriorate and the charcoal filter should be replaced every three months. TO CLEAN CELL NOTE: When handling collecting cell, extreme care should be taken so fine ionizing wires and metal plates are not damaged. (Do not wash charcoal filter.) A. Slide out pre-filter located on front of cell. Rinse thoroughly with clean warm water. Set aside to dry. B Use dishwashing detergent and the hottest water available to m...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie