Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Roberts Gorden, Modello Combat AT-136

Produttore : Roberts Gorden
File Size : 1.52 mb
File Nome : 13ead273-06fb-4b3e-99ad-124131f93898.pdf

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


• All dimensions are subject to change without notice. • Due to height of unit, additional support is recommended on top of the unit. • Dimension "F" is flue diameter. Flue located on left side of unit for 1,000 MBH heat exchanger and smaller; flue located on right side of unit for 1,250 MBH heat exchanger and larger. • Dimensions "D" and "F" may vary depending on heat exchanger size (ex. 45 = 450 MBH heat exchanger). 2 AT-Series Heating Unit with Filtration AMMBLCGDHFFKJCONTROLPANELINSPECTIONAND RELIEFPORTSPLITFOR SHIPMENTNLLIFTINGANGLESEDISCHARGE PLENUMEXTENSIONS(OPTIONAL) HEAT EXCHANGER SECTIONPROPELLER FAN / INLET SECTIONEXTERIOR FILTER RACKSDADARARARARAEND VIEWFRONT VIEWDADA DIMENSIONS AT-136 AT-148 AT-154 AT-236 AT-242 AT-248 AT-254 AT-260 AT-272 A 60 72 85 90 100 116 145 160 165 B 50 60 72 50 55 60 72 84 90 C 75 75 86 60 66 66 72 72 76 D 53 53 65 53 75 - 53 100 - 53 125 - 72 75 - 53 100 - 53 125 - 72 150 - 72 175 - 72 90 96 96 E 35 35 35 35 35 35 35 35 35 F 45 - 6 75 - 6 100 - 8 45 - 6 75 - 6 100 - 8 45 - 6 75 - 6 100 - 8 125 - 10 45 - 6 70 - 6 100 - 8 75 - 6 100 - 8 125 - 10 75 - 6 100 - 8 125 - 10 175 - 12 175 - 12 225 - 12 300 - 14 300 - 14 450 - 16 300 - 14 450 - 16 G 3 3 3 3 3 3 4 4 4 H 24 24 36 24 30 30 36 36 40 J 48 48 48 48 48 48 48 48 48 K .75 .75 .75 .75 .75 .75 .75 .75 .75 L .75 .75 .75 .75 .75 .75 .75 .75 .75 M 6 6 6 6 6 6 6 6 6 N 3 3 3 3 3 3 3 3 3 LEGEND DA = Discharge Air RA = Return Air IMPORTANT NOTES: • All dimensions are in inches. • All dimensions are subject to change without notice. • Due to height of unit, additional support is recommended on top of the unit. • Dimension "F" is flue diameter. Flue located on left side of unit for 1,000 MBH heat exchanger and smaller; flue located on right side of unit for 1,250 MBH heat exchanger and larger. • Dimensions "D" and "F" may vary depending on heat exchanger size (ex. 45 = 450 MBH heat exchanger). 3 AT-Series Cooling Unit with Filtration AKBCEDFSPLITFORSHIPMENTHLIFTING ANGLESGMLKJJDISCHARGE PLENUMEXTENSIONS(OPTIONAL) ADDITIONAL PROPELLER FAN SECTION REQUIRED FOR 254, 260, 272 MODELSPROPELLER FAN / INLET SECTIONEXTERIOR FILTER RACKS / COILS AND COIL EXTENSIONEND VIEWFRONT VIEWDADARARARARADADA LEGEND DA = Discharge Air RA = Return Air DIMENSIONS AT-136 AT-148 AT-154 AT-236 AT-242 AT-248 AT-254 AT-260 AT-272 A 60 72 85 90 100 116 145 160 165 B 50 60 72 50 55 60 72 84 90 C 75 85 95 85 85 95 90 90 90 D 48 48 48 48 48 48 48 48 48 E 6 6 6 6 6 6 6 6 6 F 24 24 36 24 30 30 36 36 40 G 10 10 16 6 10 H .75 .75 .75 .75 .75 .75 .75 .75 .75 J .75 .75 .75 .75 .75 .75 .75 .75 .75 K 6 6 6 6 6 6 6 6 6 L 3 3 3 3 3 3 3 3 3 M N/A N/A N/A N/A N/A N/A 50 50 50 IMPORTANT NOTES: • All dimensions are in inches. • All dimensions are subject to change without notice. • Due to height of unit, additional support is recommended on top of the unit. 4 AT-Series Heating and Cooling Unit with Filtration ABCGDHSPLITFORSHIPMENTINSPECTIONANDRELIEF PORTKLIFTINGANGLESLIFTINGANGLESJPELMNMLCONTROLPANELFFQEND VIEWFRON...

Questo manuale è adatto anche per i modelli :
Aria - Combat AT-148 (1.52 mb)
Aria - Combat AT-154 (1.52 mb)
Aria - Combat AT-236 (1.52 mb)
Aria - Combat AT-242 (1.52 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie