Facilità d'uso
Open the front cover. Open the front cover by pulling the upper part of it. . 2. Take out filters and remove the plastic packing. Remove the plastic packing of the filters except the pre-filter and then install filters according to the order of filters. . How to OPERATION / INDICATION PART Indication Part PREPARATIONS OPERATION/ 1 2 / Light sensor It is a sensor that detects light. 1 Speed indicator By using the speed button, it is possible to select the airflow speed in 4 steps (Step 1 > Step 2 > Step 3 > Turbo) . When the product is in sleep mode and power saving mode, the airflow speed indicators are not turned on. 2 OPERATION / INDICATION PART Operation Part 1 2 5 4 3 2 Auto mode button and its indicator Use it to select the automatic operation mode. When the auto mode is selected, the indicator is turned on. 1 Power button and its indicator Use it to turn the product on/off. When the power is on, the indicator is turned on. . To turn off the power, press and hold the power button for approximately 1 second. 4 3 Silent mode button and its indicator Use it to select the silent operation mode. When the silent mode is selected, the indicator is turned on. Mood button and its indicator Use it to turn mood lamp on/off . When mood lamp is turned on, the indicator is turned on. Speed button and its indicator Use it to select the desired airflow speed. . Pressing the speed button in auto, or silent mode makes the product immediately switch to manual mode. 5 How to It displays the current cleanliness (pollution) level of the room. OPERATION/ Clean:Blue Lightly polluted: Light purple Polluted: Dark purple Highly polluted : Red . The cleanliness (pollution) level of the room is determined by the color at the end of the penetrating hole. HOW TO USE - Before operating the product, connect the power plug to a dedicated electric outlet. - Once the power is turned on, you will see the previously used operation mode, already set for you to use. Tips ¦ To operate the manual mode Press the power button and then select the speed of the wind by pressing the speed button. . ¦ To select the auto mode Press the power button and then select the auto mode button. . . Auto mode Auto operating mode sets the wind speeds (step 1, 2, or 3) depending on the air pollution states that are detected by the pollution sensor. When the pollution levels stay in step 1 for approximately 10 minutes, the product switches to power saving mode. In the power saving mode, the fan is turned off to minimize the power consumption and all displays except the power and auto indicators are turned off. When the pollution level increases to level 2 or higher, the power saving mode is turned off. When the power saving mode continues for 30 minutes, the product temporarily switches from the power saving mode to step 1 to blend the surrounding air. Pollution level 1 Pollution level 2 Pollution level 3 or higher Power saving mode SPEED Step 1 Step 2 Step 3 Fan off How to ¦ To operate the silent mode Press the power button and then the silent button. In silent mode, the airflow speed is lowered below step 1 (lower rpm), making the environment quiet and pleasant. HOW . ¦ To operate the sleep mode(available only in auto mode operation) If the surroundings are dark for 3 minutes or longer in auto mode operation, the product automatically switches to sleep mode, lowering the airflow speed, noise, and electricity consumption.If the surroundings become bright again for 5 minutes or longer, the unit resumes normal operation. In sleep mode, all displays except the power indicator are turned off. ADJUST PARTICLE SENSOR How to Adjust the Sensitivity of the Pollution Sensor When the product is shipped out, the pollution sensor is set to standard sensitivity. If the pollution level stays at the highest level after 2 hours of operation or stays at the lowest level for more than 1 hour when the air does not seem clean, users can adjust the sensitivity of the pollution sensor as follows. 1. With the mood mode button pressed down, insert the power plug in the electric outlet. 2. With a tone ringing twice, the current sensitivity indicator of the sensor blinks. 3. Adjust the sensitivity by pressing the speed button. The sensitivity of the sensor is displayed by ablinking airflow speed indicator. Sensitive Standard Insensitive Speed step 1 Speed step 2 Speed step 3 4. After adjustment, the sensitivity of the pollution sensor is set when the power button is pressed to turn the product off or automatically set when 20 seconds have passed in the setting mode. How to CLEANING METHOD - Always unplug the air purifier before cleaning the product. - Do not use detergents that contain organic solvents (solvent, thinner, etc), bleach, chlorine, or abrasives. - Do not put the air purifier in water or spray water directly on it. Tips ADJUST CLEANING Air outletAir inlet ¦ Cleaning the pollution sensor (every 2 months) 1. Open the pollution sensor cover on the right-hand side of the product. C...
Questo manuale è adatto anche per i modelli :Aria - AP-1008CH (6.72 mb)