Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso Briggs & Stratton, Modello AP-100

Produttore : Briggs & Stratton
File Size : 857.93 kb
File Nome : dca803e9-f693-41ee-9218-f6155f92f863.pdf
Lingua di insegnamento: enesfr
Vai a scaricare



Facilità d'uso


All line connections should make good contact. Running on low voltage will damage the machine. Do not expose the machine to rain or operate the machine in damp locations. MOTOR SPECIFICATIONS Your machine is wired for 120 volts, 60 HZ alternating current. Before connecting the machine to the power source, make sure the switch is in the “OFF” position. GROUNDING INSTRUCTIONS This machine must be grounded while in use to protect the operator from electric shock. 5 1. All grounded, cord-connected machines: In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This machine is equipped with an electric cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances. Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed by a qualified electrician. Improper connection of the equipment-grounding conduc-tor can result in risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal. Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt a s to whether the machine is properly grounded. Use only 3-wire extension cords that have 3-prong grounding type plugs and matching 3-conductor receptacles that accept the machine’s plug, as shown in Fig. A. Repair or replace damaged or worn cord immediately. 2. Grounded, cord-connected machines intended for use on a supply circuit having a nominal rating less than 150 volts: If the machine is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. A, the machine will have a grounding plug that looks like the plug illustrated in Fig. A. A temporary adapter, which looks like the adapter illustrated in Fig. B, may be used to connect this plug to a matching 2-conductor receptacle as shown in Fig. B if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet can be installed by a qualified electrician. The green-colored rigid ear, lug, and the like, extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. Whenever the adapter is used, it must be held in place with a metal screw. NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electric Code. In all cases, make certain that the receptacle in question is properly grounded. If you are not sure, have a qualified electrician check the receptacle. GROUNDED OUTLET BOX CURRENT CARRYING PRONGS GROUNDING BLADE IS LONGEST OF THE 3 BLADES Fig. A Fig. B GROUNDED OUTLET BOX GROUNDING MEANS ADAPTER EXTENSION CORDS Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D-1 shows the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord. MINIMUM GAUGE EXTENSION CORD RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES Ampere Rating Volts Total Length of Cord in Feet Gauge of Extension Cord 0-6 120 up to 25 18 AWG 0-6 120 25-50 16 AWG 0-6 120 50-100 16 AWG 0-6 120 100-150 14 AWG 6-10 120 up to 25 18 AWG 6-10 120 25-50 16 AWG 6-10 120 50-100 14 AWG 6-10 120 100-150 12 AWG 10-12 120 up to 25 16 AWG 10-12 120 25-50 16 AWG 10-12 120 50-100 14 AWG 10-12 120 100-150 12 AWG 12-16 12-16 12-16 120 120 120 up to 25 25-50 14 AWG 12 AWG GREATER THAN 50 FEET NOT RECOMMENDED Fig. D-1 6 FUNCTIONAL DESCRIPTION FUNCTIONAL DESCRIPTION FOREWORD The Delta AP100 Air Purifier provides all the benefits of clean air along with lighting and portability with a 120 volt induction motor, two-stage air filtration, two integrated fluorescent bulbs, and hanging capabilities. With 450 CFM (cubic feet per minute) capacity, a coarse pre-filter and five micron inner filter, the AP100 significantly reduces wood dust to eliminate health and cleaning concerns. In addition, the AP100 features two integrated, dedicated lights for finishing applications and eye bolts for hanging the air purifier out of workshop space. NOTICE: The photo on the manual cover illustrates the current production model. All other illustrations contained in the manual are representative only and may not depict the...

Questo manuale è adatto anche per i modelli :
Aria - AP-100 (857.93 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie