|
Facilità d'uso
• Control Pad can be removed and mounted in a remote location. • Control Pad mounts in a 2”x 4” box or can be mounted in the optional Ventilation Dehumidistat or Air Sentry. • Full fan speed control. DIGITAL ELECTRONIC TIMER (DET) LOCATION: Bathrooms & kitchen • Connect up to 8 on 300' (91 m) wire max. • If a PVC or Air Sentry is used, connect up to 5 on 300' wire max. • Touch pad operation. • 20/40/60 minute status lights. • Compact wall mount unit. • Mounts in 2x4 box. • Shown with “decora” cover plate (99-107W). PART NO. 99-104 Connects to RED, GREEN and YELLOW terminals. PROGRAMMABLE VENTILATION CONTROLLER (PVC) LOCATION: Hallway, kitchen, office & work place (connect 1/unit only) • Advanced digital remote. • Digital dehumidistat. • Full fan speed control. • AIR SENTRY™ Air Quality Sensor built-in. • Recirculation mode (on compatible HRV/ERVs). • 7 day, 24 hour programmable timer. • Digital display and status lights. • 100' (30 m) maximum wire length. PART NO. 99-105 Connects to RED, ORANGE, GREEN and YELLOW terminals. *NOTE: This device is NOT compatible with the Air Sentry. NEW! VENTILATION DEHUMIDISTAT LOCATION: Central location in house. • Dehumidistat activates high speed over-ride when humidity level in home exceeds setting. • Knockout designed to accept Control Pad when remotely mounted, giving full HRV/ERV functionality & control from remote location. PART NO. 99-250 Connects to BLACK, RED, GREEN and YELLOW terminals. *Replaces 99-116 DVC & 99-230 VRD. *Only compatible with ControlAir 15 electronics. VENTILATION DEHUMIDISTAT • Three Modes of Operation - Standby/ON - 20 ON / 40 OFF - Recirculation (on compatible HRV/ERVs) Control Module Control Pad *See individual control instructions for more details. USING THE DEHUMIDISTAT Some models have a built-in dehumidistat (an exceeds the set point on the control. Once the optional remote wall mount dehumidistat can be installed, see Optional Remote Controls), to control harmful, excess humidity during the heating season. The dehumidistat operates in % of RH (relative humidity) with 80 being high and 20 being low. The average person is comfortable between 30-45%. The dehumidistat will overide the ventilator to high speed when the moisture level in the home humidity in the house is reduced, the HRV/ERV will revert back to its previous setting.The dehumidistat should be set to off for all seasons except the heating season. Note: If your HRV/ERV is equipped with an internal and an external dehumidistat, the internal one can be turned off and not used. Internal Dehumidistat with External Control Knob 16 DIMENSIONS 95MAX (470 mm) knockout for side mounting of EXHAUST return port 6" round collar converted to oval Removably Heat Recovery Core minimum 18 inches (459 mm) required for service access Drain Pan Drain spout 16" (406 mm) FRONT SIDE 18.5" 24.5"(622 mm) 95 MAX Port Specifications The 95 Max Heat Recovery Ventilator (HRV) has been designed to allow the installer to choose between two possible positions on the cabinet for the INDOOR EXHAUST (return from building) port. Illustrations in this manual show standard (side mounted) port location . The same specifications apply to both 95 Max setups, regardless of which port position is selected. HEAT RECOVERY VENTILATORS (HRVs) ¤HEAT RECOVERY VENTILATORS (HRVs) ¤ SIDE MOUNTED PORT TOP MOUNTED PORT standard location alternate location Variable Port Location Variable Port Location / Installation (Model 95 Max only) The exhaust return port collar is not factory installed. Installer may choose either side mounted or alternate top mounted port by simply removing one of the two knock-out plates and attaching a port collar (supplied). To remove knock-out plate, insert a utility knife into the knock-out slits and trace them completely to puncture protective film underneath. Then, cut the solid tabs between the slits, using tin snips or side cutters, and remove the knock-out plate. If any protective film still blocks the opening, remove it now. inches (mm) Hanging straps (4) Threaded inserts (4) at corners 18.5" EXHAUST SUPPLY Fresh air from outside Stale Air to outside 5" round collar 5" round collar EXHAUST Return air SUPPLY from building Fresh air to building Choice of port location 6" round Knockouts on top and (conv. to oval) side of unit (use 1 only) collar 6" round (conv. to oval) collar supplied In order to make the 95 Max as space efficient as possible, the INDOOR supply and return ports are converted from round to oval shape. Overall size of the port remains the same. Simply bend a standard duct fitting to the correct shape, and attach to the oval port using the same method as for a round port. TOP (470 mm) Same Circumference (6 inch) diameter Round port bent to oval 95 MAX Air Flow Stale air enters the FRONT RIGHT side port. The air will pass down the front half of the core, then up the back half of the core and out the RIGHT REAR port. Fresh outdoor air will enter the LEFT REAR port and pass down the back ha...
Questo manuale è adatto anche per i modelli :Aria - Air Purifier 155MAX (1.05 mb)
Aria - Air Purifier 200MAX (1.05 mb)
Aria - Air Purifier 95MAX (1.05 mb)
Aria - Air Purifier MAXTOP (1.05 mb)