Istruzioni per l'uso Fedders, Modello AFPB24A1

Produttore : Fedders
File Size : 339.88 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


OD) 3/4 7/8 7/8 7/8 7/8 7/8 7/8 FILTER DATA RECOMMENDED FILTER SIZE (H X W X D) (in) (FILTER NOT SUPPLIED) 16 x 20 x 1 16 x 20 x 1 16 x 20 x 1 20 x 25 x 1 20 x 25 x 1 20 x 25 x 1 20 x 25 x 1 Clearance to Combustible Material Clearances from the air handler to the combustibles are zero inches from all sides, top, and bottom; one inch from discharge air plenum; and the duct within 36 inches of the plenum. 2 Specifications subject to change without notice. Product Specifications AIRFLOW PERFORMANCE MODEL NUMBER BLOWER SPEED MEASURED STATIC PRESSURE INLET TO OUTLET (INCHES WATER COLUMN) 0.20 0.30 0.40 0.50 0.60 AFPB24A1 HIGH 925 900 850 795 690 MEDIUM 800 760 745 670 N/A LOW 655 625 600 N/A N/A AFPB24B1 HIGH 905 880 830 780 680 MEDIUM 785 735 730 655 N/A LOW 645 615 590 N/A N/A AFPB36A1 HIGH 1440 1350 1260 1180 1040 MEDIUM 1300 1220 1050 940 860 LOW 1160 1070 950 880 780 AFPC48A1 AFPC48B1 HIGH 1680 1640 1590 1520 1430 MEDIUM 1440 1410 1380 1340 1250 LOW 1240 1220 1190 1150 1100 AFPC60A1 AZFPC60B1 HIGH 2230 2105 1990 1895 1725 MEDIUM 1950 1930 1840 1770 1590 LOW 1360 1360 1350 1340 1080 Specifications applicable to upflow and horizontal applications. Air flow shown at the following conditions: -No heat elements in Air Handler. Decrease CFM 2% for 5 kW, 7.5 kW or 10 kW heat kits. Decrease CFM 1% for 15 kW or 20 kW heat kits. -60 Hertz – 230 volts. Decrease CFM 6% for 208 volt operations. -Dry coil airflow shown. 3 Specifications subject to change without notice. Accessories ELECTRIC HEATER KITS PART NUMBER DESCRIPTION USE WITH MODEL SIZE EEC05N1 5 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER ALL EEC05B1 5 KW, SINGLE PHASE, WITH CIRCUIT BREAKER ALL EEC07N1 7.5 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER ALL EEC07B1 7.5 KW, SINGLE PHASE, WITH CIRCUIT BREAKER ALL EEC10N1 10 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER ALL EEC10B1 10 KW, SINGLE PHASE, WITH CIRCUIT BREAKER ALL EEC15B1 15 KW, SINGLE PHASE, WITH CIRCUIT BREAKER AFPB36A1, AFPC48A1, AFPC48B1, AFPB60A1, AZFPB60B1 EEC20B1 20 KW, SINGLE PHASE, WITH CIRCUIT BREAKER AFPB36A1, AFPC48A1, AFPC48B1, AFPB60A1, AZFPB60B1 ELECTRIC HEAT - ELECTRICAL DATA kW 240 VAC Phase No. of Supply Circuits MBTUH 208/240 Heat Load Amps SINGLE CIRCUIT SUPPLY DUAL CIRCUIT SUPPLY Min. Wire . Ampacity Max. Fuse . Size Wire Size . Ground Size . Min. Wire Ampacity . Max. Fuse Size . Wire Size . Ground Size . AWG MM2 AWG MM2 Ckt 1 Ckt 2 Ckt 1 Ckt 2 Ckt 1 AWG / MM2 Ckt 2 AWG / MM2 Ckt 1 AWG / MM2 Ckt 2 AWG / MM2 0 1 1 --5.0 15 14 2.1 14 2.1 -------- 5* 1 1 14.8 / 17.1 20.9 30 30 10 5.3 10 5.3 -------- 7.5* 1 1 22.1 / 25.6 31.3 43 50 8 8.4 10 5.3 -------- 10* 1 1 29.5 / 34.1 41.7 57 60 6 13.3 10 5.3 -------- 15* 1 1 or 2 44.3 / 51.2 62.5 83 90 4 21.2 8 8.4 57 26 60 30 6 / 13.3 10 / 5.3 10 / 5.3 10 / 5.3 20* 1 1 or 2 59.0 / 68.2 83.4 109 110 2 33.6 6 13.3 57 53 60 60 6 / 13.3 10 / 13.3 10 / 5.3 10 / 5.3 NOTES: *kW does not include motor watts. . Ampacities and over current protection based on largest air handler motor load. Refer to specific name plate for exact ampacity and overcurrent protection size. Minimum wire ampacity values are used for sizing field power conductors. Refer to the National Electrical Code (latest version), Article 310, for sizing conductors. NOTE: when more than three current-carrying conductors are in the same conduit, the conductor's ampacity must be derated. . Maximum size fuse or HACR-type circuit breaker for field wiring protection. . Wire size based on 75°C copper wire with no more than three current-carrying conductors in the same conduit. All wiring must conform to the National Electrical Code and all local codes. 4 Specifications subject to change without notice. Product Specifications 5 Specifications subject to change without notice. ACCESS COVERTO TXV LOW VOLTCONNECTIONS LINEVOLTAGEKNOCKOUTS FINLET WIDTH HI A D E CG INLETDEPTH B DIMENSIONS Product Specifications 5 Specifications subject to change without notice. ACCESS COVERTO TXV LOW VOLTCONNECTIONS LINEVOLTAGEKNOCKOUTS FINLET WIDTH HI A D E CG INLETDEPTH B DIMENSIONS Electric Air Handle A F P B 24 A 1 * A Product Type A = Air Handler Motor P = PSC Nominal BTUH 24 = 18,000/24,000 BTU/H (5.28 kW) / (7.03 kW) 36 = 30,000/36,000 BTU/H (8.79 kW) / (10.55 kW) 42 = 42,000 BTU/H (12.31 kW) 48 = 48,000 BTU/H (14.07 kW) 60 = 60,000 BTU/H (17.58 kW) Brand Electrical Designation 1 = 208 / 230 Volts, 1 Phase, 60 Hz 2 = 220 Volts, 1 Phase, 50 Hz 3 = 208 / 230 Volts, 3 Phase, 60 Hz 4 = 460 Volts, 3 Phase, 60 Hz 5 = 230 Volts, 3 Phase, 50 Hz 6 = 380 Volts, 3 Phase, 50 Hz Residential & Light Commercial Air Handler Model Number Identification Design Series A = A Series FD-015-0407-k 6 Specifications subject to change without notice. R-22 Models R-410A Models Fedders Corporation 505 Martinsville Rd. Liberty Corner, NJ 07938 USA (908) 604-8686 Form No. F-13AH Chassis Size B = 43 3/8"H x 18"W x 22"D C = 48 3/8"H x 22"W x 26"D A Z F P C 60 B 1 * A Product Type A = Air Handler Motor P = PSC Nominal BTUH 24 = 18,000/24,000 BTU/H (5.28 ...

Questo manuale è adatto anche per i modelli :
Aria - AFPC48A1 (339.88 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie