Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso Haier, Modello HAPE200

Produttore : Haier
File Size : 1.72 mb
File Nome :
Lingua di insegnamento: enfr
Vai a scaricare



Facilità d'uso


After following these initial directions, please review the entire Use & Care Guide, to familiarize yourself with the more advanced features of your air purifier Basic Operation of the Air Purifier: 1. Take the air purifier out of the box and remove the clear plastic protective bag. Place the unit on a firm level floor or table. 2. Before turning on the air purifier, you need to confirm that the filters are firmly in place and have not become loose during shipping. To check the filters, first open the front grill. Release the front grill by placing your fingers in the recess on the bottom of the grill and pull forward. 3. Next, check the HEPA filter by pressing firmly on all four corners of the filter to ensure that it is fully inserted into the filter opening. 4. The carbon pre-filter is mounted inside the front grill with velcro tape. Confirm that it properly covers the grill vents. You may notice a few black particles coming off the pre-filter. Those particles are part of the odor-removing activated carbon and will be collected on the filter during use. 5. Place the front grill back onto the unit. First, line up the tabs on the top of the front grill with the slots inside the front of the air purifier. Then push the bottom of the grill forward until it is closed. NOTE: This unit will not operate unless the grill is in the correct position. This is a safety feature. 6. Plug the unit into a 1 15V electrical outlet and press the ( + ) key for model HAPE200, the Power Button ((Jj) for Model HAPE300, or slide the switch for HAPM1 00 to turn on your air purifier. 7. Use the \—J/ v_y keys to adjust the blower speed to the desired level. (1 circle=Low, 2 circles=Medium, 3 circles=High) See fig. 7. Model HAPE200: How To Turn Off The Unit Lower the fan speed to Level 1. Then press key, and the unit will turn off. fig. 7 - LCD Electronic Control Panel 6 English fig. 8- Remote Control: Model HAPE300 Remote control must be used in direct line of sight with air purifier. Basic functions can be conveniently operated with the remote control, except initializing the Child Lock Keypad feature. This must be done manually on the unit. IMPORTANT: You must pull the small paper insert out of the remote control at bottom, for remote control to work. You may throw away this insert after removing Filter Life Counters The carbon pre-filter and TrueHEPA filters are essential components for the long term effectiveness of your air purifier. Your air purifier has two Filter Life Counters, one for each filter type. These filter counters will monitor the percentage of useful life your filter has left, and notify you when it is time to change your filters. The exact useful life of your filters depends on your environment, but the table below gives typical life span of filters. Filter Type Typical usage Active Carbon Pre-Filter 4000 Hours TrueHEPA Filter 8000 Hours The display shows the percentage of life used since the counter was reset. Note: The percentage level increases in 10% increments. The filter life function stores data in the air purifiers memory. The unit may be unplugged and moved or stored without losing the Pre-Filter and Filter Counter values. To properly track filter usage, the Carbon Pre-Filter and HEPA Filter Life Counters should be reset each time the filters are changed. Refer to Changing the Pre-Filter or Changing the Filter for instructions on how to reset counters. 7 English Programming Locking / unlocking the Keypad Models HAPE200, HAPE300 Once your enter the desired speed, you may want to lock the keypad to prevent accidental changing of the speed. When the keypad is locked, all keys will be disabled. If you press a key, the Keypad Locked Indicator will be displayed on the screen for 1-2 seconds. Child Lock Keypad feature: 1. To lock the keypad, press and hold the ()))) / (^) keys simutaneously for 2-3 seconds. The Keypad Locked Indicator will appear on the display. Refer to Fig. 8 and 9. 2. To unlock the keypad, press and hold the ()))) / ((()) keys simutaneously for 2-3 seconds. The Keypad Locked Indicator will start blinking. Touch any key, and the unit will revert to allowing controls to be operated. resetting the Air Purifier In the unusual situation that the unit or the display is exhibiting erratic behavior, you may want to reset the air purifier. If you still have problems after resetting the air purifier, please contact Haier for additional assistance. To reset the Air Purifier 1. Unplug the unit for at least 30 seconds. 2. Plug the unit back in. fig. 9 fig. 8 8 English Air Purifier Maintenance Cleaning Your Air Purifier Proper maintenance of your Air Purifier will help ensure years of trouble free service. Follow these steps to properly maintain your air purifier: 1. Approximately every 90 days, the outside of the unit should be cleaned with a soft, damp cloth. 2. If needed, the front grill can be removed from the unit and cleaned with soapy water. Simpl...

Questo manuale è adatto anche per i modelli :
Aria - HAPE300 (1.72 mb)
Aria - HAPM100 (1.72 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie