Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso Precisionaire, Modello Alpha-HT PB1403

Produttore : Precisionaire
File Size : 113.94 kb
File Nome : 6c862938-63d4-455b-b1e0-53022bd72bdd.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


High-temperature filters are available with either a gasket or fluid seal. Filters with Blu-Jel® Fluid Seal have a maximum service temperature of 390°F (199°C) HEPA Filters Each HEPA filter has a minimum efficiency of 99.97% on 0.30 micrometer size particles when tested at rated capacity on a Q-107 Penetrometer. Each filter is challenged with an approved nearly monodispersed oil aerosol of 0.30 micrometer size and by measuring the upstream and downstream concentration of these particles with a light scattering photometer, the penetration can be determined and the efficiency can be calculated. Scan Tested HEPA Filters Each Scan Tested HEPA filter has a minimum efficiency of 99.99% on 0.30 micrometer particles. Scan testing is in accordance with Section 6.2 of IEST-RP-CC034.1, HEPA and ULPA Filters Leak Tests. In the scan test, the filter is challenged with a high concentration of an approved oil aerosol or PSL (Polystyrene Latex Spheres). The media pack and pack-to-frame seal is scanned using a photometer or particle counter to insure that there are no leaks greater than .01% of the upstream concentration at 100 fpm face velocity. Scan testing is only available for the 500°F model. Sealant Types Two types of sealants for high-temperature HEPA filters are offered. SiliconeSealant This is a high temperature (RTV) silastic-sealant silicone compound rated for continuous service up to 500°F(260°C). NOTE: This high-temperature sealant is not UL 586 approved. GlassPackSealantForExhaustAirOnly The glass pack seal is rated for continuous service up to 1,000°F(540°C) in exhaust air applications only. It is a mat of submicron glass fibers that creates a seal when compressed between the filter pack and filter frame. The glass packing is not an adhesive seal but a mechanical seal that functions much as the glass fiber medium of the filter itself. NOTE: Due to the possibility that the glass pack may shed glass fibers, the glass pack sealant should be used for exhaust systems only. Alpha HT Filter Dimensions and Capacities CFM CAPACITIES AND DIMENSIONS Filter Depth Filter Size and Actual Face CFM Capacity at Clean Weight (Inches) Frame Depth Size (Inches) Pressure Drop, Inches w.g. (Lb.) Designator .65 1.0 1.35 GG-F 24x24 650 1000 1300 38 GC-F 24x12 300 455 590 26 11-1/2 YY-F` 23-3/8x23-3/8 615 945 1235 37 YU-F 23-3/8x11-3/8 275 425 550 25 GN-F 24x30 830 1275 1655 45 CC-F 12x12 135 205 265 14 Flanders Filters - Foremost in Air Filtration Toll Free: 1-800-637-2803 ALPHA HT COMPONENT CHART 0 - 007 - C - 02 - 03 - IE - 32 - 00 - GG - F Hardware O = None T = Extractor Clips Efficiency 007 = 99.97% DOP 99.99% on .30 micrometers=SU Sealant Capacity / Pack Style C = Separator Frame Material 02 = 16 GA 409 Stainless 03 = 16 GA 304 Stainless Frame Style 03 = Double-Turned Flange 05 = 3/4 in. Deep Channel Sealant Material IE = High Temperature Silicone IG = Ceramic and Glass Mat SE = high Temperature Silicone Scan Tested (99.99% on 0.30 micrometers) Gasket Material Gasket Location 0 = None 0 = None 3 = Silicone Sponge 1 = Upstream 4 = Woven Glass 2 = Downstream 5 = Blu Jel 3 = Both Sides Filter Depth D = 5-7/8 F = 11-1/2 Filter Face Size (H x W) B=8” N=30” R=6 C=12” P=36” S=72” E=18” H=42” U=113/8 G=24” Q=48” Y=23 3/8 ODD Size Designator Odd size designators are an alpha numeric description. The first two digits specify the height whole number with an alpha designator specifying the height fraction. The second two digits specify the width whole number with an alpha designator specifying the width fraction. And the last alpha designator specifies the depth. If he height or width is less than 10 inches, use a 0 in front of the dimension. A = O” E=1/4” J=1/2” N=3/4” B=1-1/16” F=5/16” K=9/16” P=13/16” C=1/8” G=3/8” L=5/8” Q=7/8” D=3/16” H=7/16” M=11/16” R=15/16” Faceguard Material Faceguard Location 0 = None 0= None G = Aluminized Expanded Metal 1 = Upstream 5 = 22GA.SS 4x4 Mesh 2 = Downstream 3 = Both Guide Specifications 1.0General1.1 High temperature separator style HEPA filters shall be Alpha HT models as manufactured by Flanders. 1.2 Filter sizes, capacities and construction options shall be as scheduled on the drawings. 2.0FilterConstruction2.1 The filter pack shall be constructed by pleating a continuous sheet of non-woven water-resistant fiberglass media around hemmed-edge corrugated aluminum separators. 2.2 The filter pack shall be sealed into a (409 stainless steel) (304 stainless steel) frame with a high tem- perature silicone sealant rated for 500°F or a glass pack sealant rated for 1,000°F in exhaust applica- tions. 2.3 (A chlorastic silicone gasket) (a woven glass gasket) shall be provided to seal the filter in the mounting device (Gasket Seal). A silicone gel shall be provid- ed in a channel on one side to seal the filter in the mounting device. filters with silicone gel have a max- imum service temperature of 390°F (Gel Seal) 3.0Performance3.1 Initial and final resistances shall not exceed the scheduled values. 3.2 Alpha...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie