Log:
Scaricare : 8   File Size : 95 kb   Produttore : Honeywell  
Categoria : Aria
@name

The F111 removes airborne particles such as dust, soot, and some cooking smoke from the air circulated through the filter. The F111 uses a single-speed, direct-drive, forward curve blower motor with a high efficiency particulate arrestance (HEPA) filter that provides high-efficiency removal of particulates. When equipped with CPZ™ modules, the F111 also removes volatile organic compounds (VOC) and odor. This high filtration and adsorption efficiency enables the F111 to remove many of the trouble

Scaricare : 1   File Size : 149 kb   Produttore : Honeywell  
Categoria : Aria
@name

Because the F114 provides its own air circulation, it can be used in any application that requires contamination reduction in an enclosed area. SPECIFICATIONS Models: F114A Ceiling Surface-Mounted Media Air Cleaner with 99.97% HEPA filters; without CPZ canisters. F114C Ceiling Surface-Mounted Media Air Cleaner with 95% DOP filters; with CPZ disposable canisters. Color: White grille with white plenum. Electrical Ratings: 120V, 60 Hz, 1PHS, 3.6A; 220/240V, 50/60 Hz, 1PHS, 1.7A. Electrical

Scaricare : 18   File Size : 149 kb   Produttore : Honeywell  
Categoria : Aria
@name

The filters in both models are more efficient on particles larger and smaller than 0.3 micron. • Two-speed, direct-drive, forward curve blowers/motors deliver up to 325 cfm (550 cu m/hr). • Designed to overcome the increase in airflow resistance normally caused by filter loading. • Light-colored cover complements most ceiling finishes. • Models available with CPZ disposable canisters for odor control. APPLICATION The F114 Ceiling Surface-Mounted Media Air Cleaner is designed for use in res

Scaricare : 10   File Size : 149 kb   Produttore : Honeywell  
Categoria : Aria
@name

The filters in both models are more efficient on particles larger and smaller than 0.3 micron. • Two-speed, direct-drive, forward curve blowers/motors deliver up to 325 cfm (550 cu m/hr). • Designed to overcome the increase in airflow resistance normally caused by filter loading. • Light-colored cover complements most ceiling finishes. • Models available with CPZ disposable canisters for odor control. APPLICATION The F114 Ceiling Surface-Mounted Media Air Cleaner is designed for use in res

Scaricare : 0   File Size : 152 kb   Produttore : Honeywell  
Categoria : Aria
@name

4. Connect the transformer brown lead to the power supply P2 terminal. See Fig. 3 for internal schematic for the electronic air cleaner with conversion kit. CHANGE PLUG TO CONDUIT ! CAUTION ELECTRIC SHOCK HAZARD. CAN CAUSE ELECTRICAL SHOCK OR EQUIPMENT DAMAGE. Disconnect power before installing replacement power supply board. 1. In the power box, remove and retain two wire nuts that connect the line cord leads to the power box wiring. 2. Remove the power green lead from the green grounding screw

Scaricare : 8   File Size : 165 kb   Produttore : Honeywell  
Categoria : Aria
@name

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1. Read all instructions before operating the air cleaner. 2. Place air cleaner where it is not easily knocked over by persons in the household. 3. Always turn the air cleaner to the OFF position and unplug when not in use. 4. To disconnect the air cleaner, first turn speed control to OFF position, grip the plug and pull it from

Scaricare : 13   File Size : 167 kb   Produttore : Honeywell  
Categoria : Aria
@name

by Air-Pure Systems. 69-1506-4 Honeywell International Inc. makes no representations or warranties with respect to this product HOW YOUR PORTABLE AIR CLEANER WORKS Your air cleaner is effective at removing airborne particulates like dust mite allergens, pollen, mold spores, bacteria, dust, soot, and tobacco smoke particles. It is also effective at reducing annoying odors like tobacco smoke, chemical odors, and odors from cooking, when equipped with a CPZ canister. You can choose models with thes

Scaricare : 2   File Size : 167 kb   Produttore : Honeywell  
Categoria : Aria
@name

Washing can damage prefilter, HEPA filter and CPZ canister. Do not wash filters. Replace filters according to recommended schedule. Determining When to Replace Your Filters With proper maintenance, your air cleaner is designed to provide years of high- efficiency air cleaning. Your air cleaner contains up to three filters, depending on model: a carbon prefilter, a HEPA filter and a CPZ canister on some models. Replacing Your Prefilter Every Three Months (Quarterly) The carbon prefilter captures

Scaricare : 5   File Size : 167 kb   Produttore : Honeywell  
Categoria : Aria
@name

1. Air Cleaner components. 69-1506-4 6 Determining What to Do When Your Air Cleaner Does Not Operate • Check to make sure the power cord is correctly connected in the outlet. • Test the outlet with another appliance or lamp. • Check the fuse or circuit breaker; the circuit may be overloaded if other appliances are also in use. • Check to determine if the thermal overload protection device on the air cleaner motor has engaged to turn off the air cleaner. If it has, turn the air cleaner motor cont

Scaricare : 2   File Size : 193 kb   Produttore : Honeywell  
Categoria : Aria
@name

The air cleaner removes airborne particles such as dust, soot, mold spores, pollen and some cooking smoke from the air circulated through the filter. FEATURES • High Efficiency Particulate Air (HEPA) filter models are 99.97% efficient and the hospital grade particle filtermodels are 95% efficient at 0.3 micron particles. Both models are more efficient on particles smaller andlarger. There is also a 95% ASHRAE model. • Circulates up to 1230 cfm. • Designed to overcome the increase in air flow res





categorie