|
Facilità d'uso
Note: If the light does not function, check that the bulbs have been inserted correctly. 26 You can move the operating unit from the middle of the filter drawer to the left or right side. The operating unit can also be fitted at the front in a handle moulding available as an optional accessory or in the enclosed handle moulding. Moving the operating unit 1. Loosen the 2 screws from below. 2. Remove the operating unit and disconnect the plug from the ribbon cable. 3. Remove the side cover from the filter drawer. 4. Connect the plug of the side ribbon cable to the operating unit. 5. Insert the operating unit into the side of the filter drawer. Insert the excess ribbon cable. 6. Insert the cover into the middle of the filter drawer and screw on the cover from below with 2 screws. Setting the saturation indicator If the operating mode is to be switched over (exhaust air/circulating air mode), the saturation indicator for the filters must also be switched over (see Installation instructions). Faults If # or a is displayed: . See "Filters and maintenance" Section. If the extractor hood cannot be operated: . Isolate the extractor hood for approx. 1 minute by pulling out the mains plug or switching off the fuse. Then switch on again.. If you have any questions or if a fault occurs, please call Customer Service. (See list of Customer Service representatives). When you call, please quote the following: E-Nr. FD Enter the numbers in the above box. The numbers can be found on the rating plate inside the extractor hood following removal of the grease filters. Installation Instructions: Important information Old appliances are not worthless rubbish. Valuable raw materials can be reclaimed by recycling old appliances. Before disposing of your old appliance, render it unusable. You received your new appliance in a protective shipping carton. All packaging materials are environmentally friendly and recyclable. Please contribute to a better environment by disposing of packaging materials in an environmentally-friendly manner. Please ask your dealer or inquire at your local authority about current means of disposal. The extractor hood can be used in exhaust air or circulating air mode. Always mount the extractor hood over the centre of the hob. Minimum distance between electric hob and bottom edge of extractor hood: 430 mm, Fig. 1. Additional information concerning gas cookers: When installing gas hotplates, comply with the relevant national statutory regulations (e.g. in Germany: Technische Regeln Gasinstallation TRGI). Always comply with the currently valid regulations and installation instructions supplied by the gas appliance manufacturer. Only one side of the extractor hood may be installed next to a high-sided unit or high wall. Gap at least 300 mm. The installation of the extractor hood above gas cooking devices, at a minimum height of 650 mm – Fig. 1 – is permitted provided that the following nominal heat loads (Hs) are not exceeded: . Gas cookers Load of one hotplate Load of all hotplates Load of the oven max. max. max. 3.0 kW 8.3 kW 3.9 kW . Gas hobs Load of one hotplate Load of all hotplates max. max. 3.9 kW 11.3 kW . Gas ceramic hotplate The nominal heat load specifications do not apply to closed gas ceramic hobs. Always observe the specifications of the hob manufacturer. . Solid-fuel cookers The maximum nominal heat loads and the minimum distance are the same as for gas cookers. The extractor hood must not be installed over a solid fuel cooker – a potential fire hazard (e.g. flying sparks) – unless the cooker features a closed, non-removable cover and all national regulations are observed. The smaller the gap between the extractor hood and hotplates, the greater the likelihood that droplets will form on the underside of the extractor hood. Prior to installation Exhaust-air mode The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. DExhaust air must not be discharged via a smoke or exhaust gas flue which is already in use or via a shaft which is used for ventilating rooms in which fireplaces are located. Discharge exhaust air in accordance with official and statutory regulations (e.g. national building regulations). Discharge of air into smoke or exhaust air flues which are not in use requires the consent of a heating engineer. DIf the extractor hood is operated in exhaust-air mode at the same time as a flue-type heater (e.g. gas, oil or solid-fuel heater, instantaneous water heater, boiler), ensure that there is an adequate air supply which the heater requires for combustion. Safe operation is possible provided that the partial vacuum in the room in which the heater is installed does not exceed 4 Pa (0.04 mbar). This can be achieved if the combustion air is able to flow through non-lockable openings, e.g. in doors, windows and in conjunction with an air supply/air-intake wall box or by other technical procedures such as reciprocal interlock...
Questo manuale è adatto anche per i modelli :Cappe - AF280170/02 (5.19 mb)
Cappe - AF280170/03 (5.19 mb)
Cappe - AF280170/04 (5.19 mb)