Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Bosch, Modello DHI625ASD/05

Produttore : Bosch
File Size : 3.32 mb
File Nome :

Lingua di insegnamento: svendafi

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


Caution: . The mounting points shown on the template have been configured in such a way as to allow a 20 mm thick handle to be attached flush with the front edges of the cupboard. . If no handle is going to be attached, the mounting points must be brought forward by 20 mm. If the cupboard depth is greater than 280 mm, the hood can be mounted further back, . . . if the light strip under the cupboard . . . units is mounted further back, . . . if the handle is more than 20 mm thick. To do this, move the mounting points further towards the back by the corresponding distance. 3. Align the 4 enclosed mounting brackets and screw them on tight. 13 Installation inside the wall cupboard 1. Align the cupboard doors if the hinges will no longer be accessible after the extractor hood has been fitted. 2. Place the extractor hood onto the mounting brackets and push it into the cupboard. 4. Install a shelf immediately above the extractor hood. Cut holes for the pipe connection and the mains cable. Important: The extractor hood must be firmly seated on the 4 mounting brackets. 3. Loosely screw in the 4 enclosed screws. Align the extractor hood and then tighten screws. Check that the extractor hood is firmly fitted into the cupboard. 20 20 mind.15 mind. 475 If the shelf is permanently fixed inside the cupboard, 4 holes must be drilled to provide access to the 4 mounting screws for the extractor hood. 5. Route the mains cable through the hole in the wall cupboard and connect up the exhaust pipe. 6. Connect up the extractor hood to the mains. 7. If no handle is going to be attached to the vapour extractor, seal off the 3 holes with the enclosed caps. 14 Installation inside the wall cupboard 8. Cut the wall masking strip down to size if necessary and screw it onto the wall cupboard. 2. Align handle and attach it to the extractor with the 3 enclosed screws. 20 94 230 230 44 598 Attaching a handle to the vapour extractor: . A handle can be attached to the vapour extractor. . This handle can either be a wooden strip that matches the kitchen cupboards or a the handle that is available as an optional accessory (see section on optional accessories in the user instructions). 1. Use the enclosed template OIII to mark the 3 mounting points on the handle and start the hole with a gimlet. Details for drilling: l 2 mm – max. 10 mm deep. Installation inside the wall cupboard Note: The extractor hood housing inside the wall cupboard can be boarded up (e.g. with chipboard). Please observe the following: – The shelf must not be rest upon the extractor hood housing. – The board at the front should not be attached to the housing. – Ensure that access is possible for replacing filters or by Customer Service. Weight in kg: Exhaust air Re-circulating air 7,0 8,0 The manufacturer reserves the right to make design alterations in the interests of technical development. Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. This is what you have to do: 1. Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2. Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3. Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The extractor hood may only be connected to an earthed socket that has been installed according to the relevant regulations. If possible, site the earthed socket directly above the wall cupboard or in its immediate vicinity. Electrical specifications: Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1,30 m. If it is necessary to wire the extractor hood directly into the mains: The extractor hood may only be connected up by a qualified electrician approved by the appropriate electricity company. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors. This extractor hood complies with EC regulations relating to the suppression of RF interference. Kayttoohje: Laitteen kuvaus Suodatinkehys Tuuletustehon valitsimet Ylakaappi Hoyrylippa Valaistuksen kytkin Toimintatavat Hormiliitantainen: . Liesituuletin imee keittiohoyryn ja johtaa sen rasvasuodattimen lapi ulkoilmaan. . Rasvasuodatin keraa keittiohoyryn kiinteat aineet. . Keittio pysyy puhtaana rasvasta ja hajusta. D Kun liesituuletin on hormiliitantainen ja samanaikaisesti kaytossa on huoneilmaa tarvitseva tulisija (kuten esim. ka...

Questo manuale è adatto anche per i modelli :
Cappe - DHI625ASD/06 (3.32 mb)
Cappe - DHI625ASD/07 (3.32 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie