Log:
valutazioni - 0, GPA: 0 ( )

Istruzioni per l'uso Bosch, Modello DKE975R/01

Produttore : Bosch
File Size : 4.28 mb
File Nome :
Lingua di insegnamento: itenesfrdenlpt
Vai a scaricare



Facilità d'uso


Prior to installation Preparing the wall . The wall must be flat and perpendicular. . Ensure that the wall is capable of providing a firm hold for mounting screws and plugs. Weight in kg: Exhaust air Recirculating air 20,4 20,9 We reserve the right to construction changes within the context of technical development. Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. This is what you have to do: 1.Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2.Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3.Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. Electrical connection The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations. If possible, site the earthed socket directly behind the chimney panelling. . The earthed socket should be connected via its own circuit. . If the earthed socket is no longer accessible following installation of the extractor hood, ensure that there is a permanently installed disconnector. If it is necessary to wire the extractor hood directly into the mains: The extractor hood should only be connected to the electricity supply by a properly qualified electrician. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors. If the connecting cable for this appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user. Electrical data: Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1.30 m. This extractor hood corresponds to EC regulations concerning RF interference suppression. 25 Installation This extractor hood is intended to be mounted onto the kitchen wall. 1. Remove the grease filter (refer to Operating Instructions). 2. Draw a line on the wall from the ceiling to the lower edge of the hood at the centre of the location where the hood is going to be mounted. 3. Use the template to mark the points on the wall where the screws will be mounted. In order to make it easier to hook the hood onto the screws, draw the outline of the area where the hood will be attached. Ensure that the minimum distance between the hob and the extractor hood is maintained – 550 mm for an electric hob and 650 mm for a gas hob. The bottom edge of the template equates to the lower edge of the extractor hood. 4. Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling. Insert plugs into the holes so that they are flush with the wall. 7. Attach the extractor hood. Adjust the height and align horizontally with the adjusting screws. Note: Take into account any special accessories that are going to be fitted. 5. Attach the 2 enclosed spacers to the fixing bracket for the flue duct panelling. 6. Screw on the upper and the two lower fixing brackets. 26 Installation 08. Screw in lower screws (hex screws). 09. Stick protective film over the holes of the 2 lower mounting bolts in the protective grid. 12. Remove the protective film from the two flue ducts. Take care not to damage the surfaces which are susceptible to scratches etc. 13. Push both sections of the flue panelling together (slots in the upper section must be pointing downwards) and insert into the opening in the extractor hood. Protect the cover panels from scratches, for example by laying the template used for marking the wall over the top edge of the lower section. 10. Connect up the air outlet pipe. 11. Connect the hood to the electricity supply. 14. Slide out the upper section and attach it to the mounting brackets at the sides with two screws. 1. 2. 3. 15. Insert the grease filter (refer to Operating Instructions). 1. 2. Mode d’emploi Description de l'appareil Eclairage Commutateur Lumiere/ Ventilateur Capot de cheminee Grille du filtre Modes de fonctionnement Air evacue a l'exterieur: . Le ventilateur de la hotte aspire les buees de cuisson qui traversent un filtre a graisse avant de regagner l'atmosphere exterieure. . Ce filtre retient les particules grasses solides en suspension dans les buees de cuisson. . Les particules grasses ne se deposent plus dans la cuisine, les odeurs de cuisson disparaissent. DSi la hotte evacue l'air a l'exterieur et si le logement comporte des ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie