Log:
valutazioni - 0, GPA: 0 ( )

Istruzioni per l'uso Bosch, Modello D76F35N0GB/01

Produttore : Bosch
File Size : 697.62 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


regional building laws). • If the exhaust air is conveyed through the outer wall, a telescopic wall box should be used. To ensure optimum performance, the extractor hood requires: – a short, straight exhaust air pipe and – the largest possible pipe diameter. • If pipe bends cannot be avoided, ensure the largest possible radii. NOTE: If long, rough exhaust air pipes, a lot of pipe bends or pipe diameters less than 150 mm are used, the air capacity will be less than optimum and there will be an increase in noise. • Use only pipes or hoses made of noncombustible material for installation of the exhaust air duct. • The manufacturer of the extractor hoods is not responsible for complaints which can be attributed to planning and design of the pipework. Connecting pipes • The diameter of the exhaust air pipes should not be less than 150 mm. • Round pipes: We recommend an inner diameter of 150 mm, however at least 120 mm. • Flat ductsmust have the same inner cross- section as round pipes. There should be no sharp bends. O150 mm approx. 177 cm2 O120 mm approx. 113 cm2 • If pipe diameters differ: Use sealing strips. Connection of 150 mm o exhaust air pipe(recommended size) • Attach exhaust air pipe directly to the air-pipe connector and seal appropriately. If using an aluminium pipe, smooth the connection area beforehand. Connection of 120 mm o exhaust air pipe • Attach reducing connector directly to the air- pipe connector. • Attach exhaust air pipe to the reducing connector. • Seal both joints appropriately. Installation instructions ELECTRICALCONNECTION • Before connecting the appliance to the power supply, always follow the instructions and warnings in the chapter entitled ”Safety instructions”! • The extractor hood may only be connected by a qualified electrician who is familiar with the regulations of the relevant electricity supply company. RISK OF INJURY If the power cord of the extractor hood is damaged, it must be replaced by the manufacturer, his customer service or a similarly qualified person to prevent hazardous situations. • The extractor hood may be connected to a correctly installed earthed socket only. • Attach the earthed socket as directly as possible behind the flue duct. – The earthed socket should be connected via its own circuit. – If the earthed socket is no longer accessible following installation of the extractor hood, a disconnector must be fitted as for a permanent connection. If a permanent connection is required • A disconnector must be provided on the installation side. Switches with a contact opening of more than 3 mm and all-pole disconnection are regarded as disconnectors. This includes LS switches, fuses and contactors. Electrical specifications WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow–Earth Blue–Neutral Brown–Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. This is what you have to do: 1.Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol<, or coloured green or green and yellow. 2.Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’or coloured black. 3.Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The required connection data can be found on the rating plate inside the appliance when the grease filters have been removed. Length of the power cord: approx. 1.30 m. This extractor hood complies with the EC interference suppression regulations. Installation The extractor hood is designed to be mounted on the wall. • During installation, optional accessories may also require fitting. • Observe the minimum distance between hob and extractor hood (see ”Safety instructions”)! • Avoid damaging the sensitive surfaces! Preparing the wall RISK OF INJURY, DAMAGE TOPROPERTY Before drilling the holes for the designated installation location, check for concealed electrical cables and other lines. The wall must be level and vertical. • The enclosed screws and wall plugs are suitable for solid brickwork. Use the appropriate fixing materials for other wall structures (e.g. plaster board, porous concrete, poroton bricks). Ensure that the wall has adequate load bearing capacity. • Ensure that the depth of the drilled holes corresponds with the length of the screws. • Ensure that the wall plugs are secure. Max. weight in kg: 40 Design subject to modification in line with technical development. Installation preparations 1.Mark a centre line on the wall from the ceiling to the lower edge of the extractor hood. 2.Using the enclosed template, mark positions for the screws and, to facilitate attachment, the contour of the attachment area. The lower edge of the template corresponds to the lower edge of the extractor hood. 3.Drill 2x 8 mm holes for attachment of the extractor hood and 2x 8 mm holes for the f...

Questo manuale è adatto anche per i modelli :
Cappe - D77F35N0GB/01 (697.62 kb)
Cappe - D79F35N0GB/01 (697.62 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie