. Flat ducts must have an internal cross- section that equates to that of round pipes. There should be no sharp bends. l120 mm approx. 113 cm2 l150 mm approx. 177 cm2 . If pipes have different diameters: Insert sealing strip. . For exhaust-air mode, ensure that there is an adequate supply of fresh air. Circulating-air mode . With activated carbon filter if exhaust-air mode is not possible. The complete installation set can be obtained from specialist outlets. The corresponding accessory numbers can be found at the end of these operating instructions. Connecting a l150 mm exhaust-air pipe: . Mount the pipe directly onto the air outlet on the hood. Connecting a l120 mm exhaust-air pipe: . Insert the reducing connector into the air connector, drill 2x l3 mm holes and screw together. . Attach the exhaust-air pipe to the reducing connector. 29 775- 1220 mind. 120 250 350 580 520 90 565 mind.550 mind.120 315 Prior to installation Electrical connection Preparing the wall . The wall must be flat and perpendicular. . Ensure that the wall is capable of providing a firm hold for mounting screws and plugs. . Appliances with a rear light: A recess panel or tiles fitted to the wall directly under the extractor hood must not project by more than 15 mm, otherwise the light cover may be damaged. Weight in kg: Exhaust air Recirculating air 60 cm 20,2 22,4 90 cm 23,2 25,4 We reserve the right to construction changes within the context of technical development. Changing over from exhaust- air to recirculating mode Changing the electronic control system to recirculating mode: . The standard factory setting is for operation in exhaust-air mode. . To change the mode, the extractor hood must have been connected up and should be switched off. 1. Press and hold down the Lbutton. 2. Press the button for approx. 3 seconds. . A ais displayed. 3. Release the buttons. . The display goes out shortly afterwards. Resetting to exhaust-air mode: 1. Repeat the procedure. . A ~is displayed. 2. Release the buttons. . The display goes out shortly afterwards. WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. This is what you have to do: 1. Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2. Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3. Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations. If possible, site the earthed socket directly behind the chimney panelling. Electrical data: Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1.30 m. If it is necessary to wire the extractor hood directly into the mains: The extractor hood should only be connected to the electricity supply by a properly qualified electrician. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors. This extractor hood corresponds to EC regulations concerning RF interference suppression. Installation This extractor hood is intended to be mounted onto the kitchen wall. 1. Remove the grease filter (refer to Operating Instructions). 2. Draw a line on the wall from the ceiling to the lower edge of the hood at the centre of the location where the hood is going to be mounted. 3. Using the template, mark positions on the wall for the screws. Ensure that the minimum distance between the hob and the extractor hood is maintained – 550 mm for an electric hob and 650 mm for a gas hob. The bottom edge of the template equates to the lower edge of the extractor hood. 4. Drill 4 x l8 mm holes for the extractor hood and 2 x l8 mm holes for the chimney panelling. Insert plugs into the holes so that they are flush with the wall. 15 300 270 411 90 160 mind.550 Elektro mind.650 Gas Note: Take into account any special accessories that are going to be fitted. 5. Attach the fixing bracket for the chimney panelling using two hexagon head cap screws. 6. Screw in the two upper hexagon head cap screws leaving them extended by approx. 5 mm. 7. Attach the extractor hood to the screws. ca.5mm Installation 8. Screw in the two lower hexagon head 13. Push both sections of the flue panelling cap screws. together (slots in the upper section Before the 4 screws are tightened must be pointing downwards) and insert into the opening in the ...
Questo manuale è adatto anche per i modelli :Cappe - D8985N1/02 (2.95 mb)
Cappe - D8985N1/03 (2.95 mb)
Cappe - D8985N1/04 (2.95 mb)