This is what you have to do: 1. Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2. Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3. Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations. If possible, site the earthed socket directly behind the chimney panelling. q The earthed socket should be connected via its own circuit. q If the earthed socket is no longer accessible following installation of the extractor hood, ensure that there is a permanently installed disconnector. If it is necessary to wire the extractor hood directly into the mains: The extractor hood should only be connected to the electricity supply by a properly qualified electrician. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors. If the connecting cable for this appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user. 23 Electrical connection Electrical data: Are to be found on the name plate inside the appli ance after removal of the filterframe. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. en Length of the connecting cable: 1.30 m. This extractor hood corresponds to EC regulations concerning RF interference suppression. Installation 1. Draw a line on the wall from the ceiling to the lower edge of the hood at the centre of the location where the hood is going to be mounted. 2. Use the template or following the picture to mark the points (A-B-C) on the wall where the screws will be mounted. Ensure that the minimum distance between the hob and the extractor hood is maintained 460 mm for the gas hob and electric hod 3. Drill o 8 mm holes A and B for the extractor hood. Drill o 8 mm holes C for the chimney brackets. 4. Insert plugs 11 into the holes A,B and C so that they are flush with the wall. Installation 5. Fix the brackets 7.2.1 using the screws supplied. 6. Insert not totally the screw into the holes A. Mounting the hood body 7. Before attaching the hood body, tighten the two screws Vr located on the hood body mounting points. 8. Hook the hood body onto the screws 12a into the holes A. 9. Fully tighten support screws 12a. 10. Adjust screws Vr to level the hood body. 11. Tighten the safety screw 11 in holes B. Connection in Ducting Version When installing the ducting version, connect the hood to the chimney using either a flexible or rigid pipe o 150 or 120 mm, the choice of which is left to the installer. q To install a o 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. q Fix the pipe in position using sufficient pipe clamps (not supplied). Note: Take into account any special accessories thataregoingtobefitted. min. 460 Elektro Gas* 20 595 232 135 Min. 1050- Max. 1350 AABCC210 CC ...................... q Remove charcoal filters, if present. 24 Installation Connection in Recirculation Version All the items named in this procedure are included in the recirculation kit. The correspond ing accessory numbers can be found at the end of these operating instructions. q Put connection 15 into the connection support 7.3, previously fix with the upper bracket support chimne 7.2.1, and secure with a screw. q Insert the connection extension pieces laterally 14.1 in connection 15. q Make sure that the outlet of the extension pieces 14.1 is horizontally and vertically aligned with the chimney outlets. q Connect the air outlet connection 15 to the hood body outlet using either a pipe o 150 mm. q Use the jubilee clips 25 to ensure a fix connection between pipe and hood outlet and between pipe and connection (15). q Ensure that the activated charcoal filters have been inserted.(see parag. “Activated carbon filter” in Filters and Maintenance chapter) en .............. 25 Installation Chimney assembly Upper Chimney q Slightly widen the two sides of the upper Chimney and hook them behind the brackets 7.2.1, making sure that they are well seated. q Secure the sides to the brackets using the 4 en screws 12c supplied. q Make sure that the outlet of the extensions pieces is aligned with the chimney outlets. Lower Chimney q Slightly widen the two sides of the Chimney and hook them between the upper Chimney and the wall, making sure that they are well seated. q Fix the lower part laterally to the hood body using the 2 screws 12c supplied. ................................ 26 Mode d’emploi Description de l'appareil Commandes Eclair. / Mot. Conduit Eclairage Filtres Modes de fonctionnement Fonctionnement a evacuation de l'air : q ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie