Log:
valutazioni - 0, GPA: 0 ( )

Istruzioni per l'uso Bosch, Modello HPIB42HS/01

Produttore : Bosch
File Size : 4 mb
File Nome :
Lingua di insegnamento: enesfr
Vai a scaricare



Facilità d'uso


Safe operation is possible provided that the under pressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar). This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the air-intake/ exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc. CAUTION Avoid carbon monoxide poisoning – Provide adequate air intake so combustion gases are not drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as cooktops and ovens. CIRCULATING-AIR MODE: . An activated carbon filter must be fitted for this operating mode (see Filters and maintenance). The complete installation set and replacement filters can be obtained from specialist outlets. . The extractor-hood fan extracts the kitchen vapours which are purified in the grease filter and activated carbon filter and then conveyed back into the kitchen. . The activated carbon filter binds the odorous substances. If no activated carbon filter is installed, it is not possible to bind the odorous substances in the cooking vapours. Gas Cooktops / Gas Ranges: CAUTION Avoid risk of burns or damage to extractor hood. Do not use all gas burners simultaneously at high settings for a prolonged period (max.15 minutes). If the hood is located over a gas cooktop, operate the hood at maximum setting whenever three or more gas burners are being used. OPERATION IMPORTANT: The most effective way to remove vapors produced during cooking is to: . Switch the ventilator ON as soon as you begin cooking. . Switch the ventilator OFF a few minutes after you have finished cooking. Switching the fan ON . Press the LO MED HI button. Setting the required fan speed: . Press the LO MED HI button. The fan speed increases by one level. Switching the fan OFF: . Press the OFF button. Delay shut-off: . Press the DELAY button. The fan runs for 10 minutes on HI. At the same time, a dot flashes in the display. Then the fan switches off automatically. The illuminated LED indicates that DELAY SHUT-OFF is working. Lighting: . Press the LIGHT button to switch the light on and off. . The light can be switched on at any time, even if the fan is switched off. 9 FILTERS AND MAINTENANCE GREASE FILTERS: Metal filters are used to trap the greasy element of the vapors that develop during cooking. The filter mats are made from noncombustible metal. Caution: As the filter becomes more and more saturated with grease, not only does the risk of it catching fire increase but the efficiency of the hood can also be adversely affected. Important: By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up of heat such as occ...

Questo manuale è adatto anche per i modelli :
Cappe - HPIB42HS/02 (4 mb)
Cappe - HPIB48HS/01 (4 mb)
Cappe - HPIB48HS/02 (4 mb)
Cappe - HPIN42HS/01 (4 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie