. Keep pressing the + button until a c appears in the display. . If the intensive setting is not cancelled by hand, the fan will automatically switch back to step } after 10 minutes. Fan follow-on: . Press the ! button. The fan continues to run at step | for 10 minutes, and at the same time a dot flashes in the display. After this period the fan switches off automatically. Lighting: . The light can be switched on at any time, even though the fan is switched off. Querying the selected operating mode: The extractor hood must be connected and switched off. When the button – is pressed twice (within 1 second), the ~symbol is indicated if the hood has been set to exhaust air mode, the Csymbol is indicated if the hood has been set to circulating air mode. Filters and maintenance Grease filters: Metal filters are used to trap the greasy element of the vapours that develop during cooking. The filter mats are made from noncombustible metal. Caution: As the filter becomes more and more saturated with grease, not only does the risk of it catching fire increase but the efficiency of the extractor hood can also be adversely affected. Important: By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up of heat such as occurs when deep-fat frying or roasting is taking place, is reduced. Saturation indicator: ~ When the grease filters are saturated, ~ flashes. The grease filters should be cleaned now. Cleaning the metal grease filters: . In normal operation (1 to 2 hours daily), the metal grease filter must be cleaned 1 x a month. . The filters can be cleaned in a dishwasher. It is however possible that they will become slightly discoloured. . The filter must be placed loosely, and NOT wedged, in the dishwasher. Important: Metal filters that are saturated with grease should not be washed together with other dishes etc. . When cleaning the filters by hand, soak them in hot soapy water first of all. Do not use aggressive, acidic or caustic cleaners. Then brush the filters clean, rinse them thoroughly and leave the water to drain off. Removing and installing the edge extraction segments and the metal-mesh grease filters: Attention: The halogen bulbs must be switched off and must have cooled down. 1. Take hold of the edge extraction segments at the side, pull them down and remove, Fig. 1. 2. Depress the handles on the grease filters and fold down the grease filters, Fig. 1. 3. Clean the grease filters. 4. Re-install the cleaned grease filters. 5. Attach the edge extraction segments in reverse sequence. 6. Clearing the # display. Press the button 2 x in succession. A signal sounds and the # display goes out. Activated carbon filter: For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired. Important: Change the activated carbon filter promptly to prevent the risk of fire from the accumulation of heat when deep-fat frying or roasting. Saturation indicator: b When the activated carbon filter is saturated, Cflashes. The activated carbon filter should be changed now. Filters and maintenance Installation: Attention: The halogen bulbs must be switched off and must have cooled down. 1. Remove the grease filters (see Removing and installing the edge extraction segments and the metal-mesh grease filters). 2. Insert the activated carbon filter. Fig. 2. 3. Lift the activated carbon filter at the front and rotate the catches through 90°. Fig. 3. 4. Re-install the grease filters and the edge extraction segments in reverse sequence. 5. Clearing the a display. . Press the button 2 x in succession. A signal sounds and the C display goes out. Replacing the activated carbon filter: . During normal operation (1 to 2 hours per day) the activated carbon filters should be replaced approximately 1 x year. . A replacement filter can be obtained from any authorized dealer. . Use original filters only. By doing so you will obtain maximum performance from your extractor hood. Disposing of the old activated carbon filter: . There are no pollutants in the activated carbon filters. They can therefore be disposed of as part of your normal domestic refuse. Cleaning and care Isolate the extractor hood by pulling out the mains plug or switching off the fuse. Do not clean the extractor hood with abrasive sponges or with cleaning agents which contain sand, soda, acid or chlorine! . Clean the extractor hood with a hot soap solution or a mild window cleaner. . Do not scrape off dried-on dirt but wipe off with a damp cloth. . When cleaning the grease filters, remove grease deposits from accessible parts of the housing. This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency. . Note: Do not use alcohol (spirit) on plastic surfaces, as dull marks may appear. Caution: Ensure that the kitchen is adequate...
Questo manuale è adatto anche per i modelli :Cappe - LF359BA80/01 (1.43 mb)