Facilità d'uso
2. Insert an activated carbon filter on the right and left of the fan motor and rotate the filters until they lock into position. 1. 2. Filters and maintenance 2. Clean the filters. 3. Insert the clean filters back into the hood. Activated carbon filter: For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired. Important: Change the activated carbon filter promptly to prevent the risk of fire from the accumulation of heat when deep-fat frying or roasting. Removing and inserting the metal grease filters: 1. Press the catch on the grease filters inwards and fold the filters down. At the same time take hold of the underside of the grease filters with your other hand. 8 Replacing the light bulbs 1. Switch off the extractor hood and pull out the mains plug or switch off the electricity supply at the fuse box. 2. Remove the grease filters (see Filters and Maintenance). 3. Press down the bulb cover and disconnect from the light strip. 4. Replace the bulb (standard filament bulb, max 40 W, E14 bulb holder). 5. Attach the lamp cover again. 6. Re-insert the grease filters. 7. Plug the appliance into the mains or switch it on at the fuse box. Cleaning and care Isolate the extractor hood by pulling out the mains plug or switching off the fuse. Do not clean the extractor hood with abrasive sponges or with cleaning agents which contain sand, soda, acid or chlorine! . Clean the extractor hood with a hot soap solution or a mild window cleaner. . Do not scrape off dried-on dirt but wipe off with a damp cloth. . When cleaning the grease filters, remove grease deposits from accessible parts of the housing. This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency. Clean the switch with a soft, damp cloth (mild detergent solution) only. Do not use stainless steel polish on the switch. Stainless steel surfaces: . Use a mild non-abrasive stainless steel cleaner. . Clean the surface in the same direction as it has been ground and polished. . We recommend our stainless steel cleaner no. 461731. See enclosed service booklet for order address. Aluminium, coated and plastic surfaces: . Do not use dry cloths. . Use a mild window cleaning agent. . Do not use aggressive, acidic or caustic cleaners. Observe the warranty regulations in the enclosed service booklet. Installation Instructions: Important information Old appliances are not worthless rubbish. Valuable raw materials can be reclaimed by recycling old appliances. Before disposing of your old appliance, render it unusable. You received your new appliance in a protective shipping carton. All packaging materials are environmentally friendly and recyclable. Please contribute to a better environment by disposing of packaging materials in an environmentally-friendly manner. Please ask your dealer or inquire at your local authority about current means of disposal. The extractor hood can be used in exhaust air or circulating air mode. Always mount the extractor hood over the centre of the hob. Minimum distance between electric hob and bottom edge of extractor hood: 550 mm, Fig. 1. The extractor hood must not be installed over a solid fuel cooker – a potential fire hazard (e.g. flying sparks) – unless the cooker features a closed, non-removable cover and all national regulations are observed. The smaller the gap between the extractor hood and hotplates, the greater the likelihood that droplets will form on the underside of the extractor hood. Additional information concerning gas cookers: When installing gas hotplates, comply with the relevant national statutory regulations (e.g. in Germany: Technische Regeln Gasinstallation TRGI). Always comply with the currently valid regulations and installation instructions supplied by the gas appliance manufacturer. Only one side of the extractor hood may be installed next to a high-sided unit or high wall. Gap at least 50 mm. Minimum distance on gas hotplates between the upper edge of the trivet and lower edge of the extractor hood: 650 mm, Fig. 1. Prior to installation Preparing t h e w a l l . The wall must be flat and perpendicular. . Make sure that the wall can bear the applied loads. . The provided screws and wall plugs are suitable for solid masonry. On all other wall types (e.g. plasterboard, porous concrete, Poroton bricks) use the appropriate fasteners. . Ensure that the wall is capable of providing a firm hold for mounting screws and plugs. Weight in kg: Exhaust air Recirculating air 60 cm 12,5 13,5 70 cm 13,0 14,0 90 cm 13,9 14,9 100 cm 14,8 15,8 120 cm 16,0 17,5 We reserve the right to construction changes within the context of technical development. Prior to installation Exhaust-air mode The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. DExhaust air should neither ...
Questo manuale è adatto anche per i modelli :Cappe - LC663WA10B/01 (930.4 kb)
Cappe - LC953WA10B/01 (930.4 kb)
Cappe - LC963WA10B/01 (930.4 kb)