Facilità d'uso


• Flat ducts must have the same inner cross- section as round pipes. There should be no sharp bends. O150 mm approx. 177 cm2 O120 mm approx. 113 cm2 • If pipe diameters differ: Use sealing strips. Connection of 150 mm o exhaust air pipe(recommended size) • Attach exhaust air pipe directly to the air-pipe connector and seal appropriately. If using an aluminium pipe, smooth the connection area beforehand. Connection of 120 mm o exhaust air pipe • Attach reducing connector directly to the air- pipe connector. • Attach exhaust air pipe to the reducing connector. • Seal both joints appropriately. Installation instructions ELECTRICAL CONNECTION • Before connecting the appliance to the power supply, always follow the instructions and warnings in the chapter entitled ”Safety instructions”! • The extractor hood may only be connected by a qualified electrician who is familiar with the regulations of the relevant electricity supply company. RISK OF INJURY If the power cord of the extractor hood is damaged, it must be replaced by the manufacturer, his customer service or a similarly qualified person to prevent hazardous situations. • The extractor hood may be connected to a correctly installed earthed socket only. • Attach the earthed socket as directly as possible behind the flue duct. – The earthed socket should be connected via its own circuit. – If the earthed socket is no longer accessible following installation of the extractor hood, a disconnector must be fitted as for a permanent connection. If a permanent connection is required • A disconnector must be provided on the installation side. Switches with a contact opening of more than 3 mm and all-pole disconnection are regarded as disconnectors. This includes LS switches, fuses and contactors. Electrical specifications The required connection data can be found on the rating plate inside the appliance when the grease filters have been removed. Length of the power cord: approx. 1.30 m. This extractor hood complies with the EC interference suppression regulations. Installation The extractor hood is designed for installation on the kitchen ceiling or on a rigid suspended ceiling. • During installation, optional accessories may also require fitting. • Observe the minimum distance between hob and extractor hood (see ”Safety instructions”)! • Avoid damaging the sensitive surfaces! Preparing the ceiling RISK OF INJURY, DAMAGE TO PROPERTY Before drilling the holes for the designated installation location, check for concealed electrical cables and other lines. • The ceiling must be level and horizontal. • The enclosed screws and wall plugs are suitable for concrete and natural stone.Use the appropriate fasteners for other ceiling structures. Ensure that the ceiling has adequate load bearing capacity. • Ensure that the depth of the drilled holes corresponds with the length of the screws. • Ensure that the wall plugs are secure. Max. weight in kg: 50 Design subject to modification in line with technical development. Installing the upper support frame 1. Specify the total height of the support frame before installation and mark the screw holes. The height of the support frame can be adjusted in 20 mm steps. The total height is measured from the height of the ceiling, the height of the worktop and the corresponding distances between the hob and extractor hood. 2. On the ceiling mark the centre point of the extractor hood. 3. Using the enclosed template, mark the positions for the screws on the ceiling. 4. Drill 4x 8 O mm holes and press in wall plugs flush with the ceiling. 5. Attach the upper part of the support frame to the ceiling with 4 screws. 6. Ensure that the support frame is in the correct position. The middle bracket defines the preferred side. It must be facing the hob control. 31 Installation Installing the lower support frame Attach upper and lower parts of the support frame at the specified total height with 10 screws (preferred hole selection, see diagram). Ensure that the lower support frame is in the correct position. The open side must be facing the hob control. NOTE: The support frame can be aligned subsequently by loosening the fastening screws on the ceiling. Installing the extractor hood 1. Hook the extractor hood from below into the support frame. Do not trap the power cord! 2. Attach the extractor hood to the support frame with 2 securing screws. 3. Hook in retaining clip and screw tight. 4. Connect the pipes. 5. Connect the power supply. Exhaust-air mode 700-880 Circulating-air mode 700-1000 Installation Installing the flue ducts 4. Push up the upper flue part and secure with 2 screws. RISK OF INJURY The insides of the flue ducts may have sharp edges. We recommend wearing protective gloves during installation. 1. Separate the flue ducts.To do this, remove the adhesive tape. 2. Remove the protective film from both flue ducts. 3. Attach both parts of the upper flue to the extractor hood und push together. NOTE: Protect the extractor hood from damage...

Questo manuale è adatto anche per i modelli :
Cappe - LF957GA40/01 (2.1 mb)
Cappe - LF957GA40/02 (2.1 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie