|
Facilità d'uso
. Diameter of pipe to be as large as possible and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise. The manufacturer of the extractor hoods accepts no liability for complaints which can be attributed to the design and layout of the pipework. . Round pipes: We recommend Internal diameter: 150 mm (at least 120 mm). . Flat ducts must have an internal cross- section that equates to that of round pipes. There should be no sharp bends. l120 mm approx. 113 cm2 l150 mm approx. 177 cm2 . If pipes have different diameters: Insert sealing strip. . For exhaust-air mode, ensure that there is an adequate supply of fresh air. Connecting a l150 mm exhaust-air pipe: . Mount the pipe directly onto the air outlet on the hood. Connecting a l120 mm exhaust-air pipe: . Attach the reducing connector (enclosed or available from specialist retailer) to the air pipe and then attach to the exhaust-air duct. If a one-way flap has been fitted, conduct a performance test. Prior to installation Circulating-air mode . With activated carbon filter if exhaust-air mode is not possible. 51-318 323 max. 1080 mind. 813 522 a- o Electrical connection This is what you have to do: 1.Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2.Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 170 250 500 600/700/ 900600/700/9001000/1200 The extractor hood should only be connected to an earthed socket that has a 3.Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. been installed according to relevant regulations. If possible, site the earthed socket directly The complete installation set can be behind the chimney panelling. obtained from specialist outlets. Preparing the wall . The wall must be flat and perpendicular. . Ensure that the wall is capable of providing a firm hold for mounting screws and plugs. Weight in kg: . The earthed socket should be connected via its own circuit. . If the earthed socket is no longer accessible following installation of the extractor hood, ensure that there is a permanently installed disconnector. If it is necessary to wire the extractor hood directly into the mains: The extractor hood should only be Exhaust air Recirculating air 60 cm 12,5 13,5 70 cm 13,0 14,0 90 cm 13,9 14,9 100 cm 14,8 15,8 120 cm 16,0 17,5 connected to the electricity supply by a properly qualified electrician. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors. If the connecting cable for this We reserve the right to construction changes within the context of technical development. Electrical connection appliance is dam...
Questo manuale è adatto anche per i modelli :Cappe - 3BD7124XP/01 (2 mb)
Cappe - 3BD7124XP/02 (2 mb)
Cappe - 3BD761BP/01 (2 mb)
Cappe - 3BD761BP/02 (2 mb)