Log:
valutazioni - 2, GPA: 3 ( )

Istruzioni per l'uso Beverage-Air, Modello 66000I

Produttore : Beverage-Air
File Size : 427.83 kb
File Nome : fc044d88-571e-08b4-55d4-08db7c89c6de.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


If the ambient temperature is cold (i.e. in Winter), the gasket may not fit perfectly to the cabinet. In that case, wait for the natural fitting of the gasket or accelerate this process by heating up the part involved with a normal hairdryer on a low setting. 3 10 11 9 12 13 Building the appliance in under a worktop . The dimensions of the recessed installation area must correspond with those indicated in the figure. 600 550min. 600 2xC . Installation kit 12 1 2 1xA 1xB 1 1 2 2 Two cabinet securing brackets + are supplied with the installation pack. They need to be assembled onto the cabinet prior to cabinet being pushed into the Kitchen aperture. Left hand bracket Right hand bracket 1/a + To fit these brackets remove the two screws at the top left and right hand front corners of the cabinet. + Position the two brackets as shown in the figure and replace the two securing screws. + Push the appliance into place. The plug socket necessary for connection of the appliance to the electricity supply should be positioned, so that the plug is not placed in the recess. To adjust the height proceed as follows: + Loosen or tighten the two front feet. + The rear feet are adjusted by turning the screw in the front kick plate to the left or right. + If necessary, pads are supplied for the rear feet to make sliding the appliance in and out of the recess easier. To fit the pads, press them onto the rear feet. If required, the dimensions of these pads can be reduced by breaking them where marked. 555max - 2 2/a N.B. The joint cover (B) is to be assembled after having installed the appliance in the recess. 4 115° 3 12 B Push the appliance into + place and retain the cabinet with screws through the securing brackets into the worktop or adjacent woodwork as necessary. 5 To mount the furniture door + proceed as shown in the figures: 6 a b 10 1 2 3 4 C 7 8 a clic C clic C b c Upper part of kitchen furniture panel 9 b a = = 1 2 Lower part of kitchen furniture panel 9/a 275 275 max 100 11 = = 10 10 1 2 3 45 ° Refit the covering strip. + 13 A 12 580 a = 100b = 150 25 - 80 A = 820B = 870 25 580 a = 100b = 150 25 - 80 A = 820B = 870 25 Fitting the plinth Important! For the efficient operation of the appliance, it is important that the original ventilation grid is used. • For an opening height dimension A=820 mm and a plinth height dimension a=100 mm, the plinth may be fitted without adjustments. The same applies to an opening height dimension B=870 mm and a plinth height dimension b=150 mm. • For plinth heights greater than a=100 mm, b=150 mm, a cut should be made in the plinth, 580 mm wide, in the centre of the appliance position, leaving a remaining height of a=100 mm, b=150 mm. • Attach plinth to the kitchen units. Important! The plinth must be positioned at a minimum distance of 25 mm from the door. Please check whether, after installing your appliance and especially after reversing the door, the door seal seals right round. A badly fitting door seal may lead to heavy frosting and result in a higher power consumption (see also “What to do if ...”). Power supply A correctly installed, earthed socket is required for the electrical supply. The supply must have a fuse rating of at least 10 Amps. If the socket is not accessible once the appliance is built in, the electrical installation must include suitable means of isolating the appliance from the mains (e.g. a fused spur). . Before initial start-up, refer to the appliance rating plate to ascertain if supply voltage and current values correspond with those of the mains at the installation location. e.g.: AC 220 ... 240 V 50 Hz or 220 ... 240 V ~50 Hz (i.e. 220 to 240 volts alternating current, 50 Hertz) The rating plate is inside the appliance on the left. The mains cable may only be changed by a qualified electrician or competent person. If your appliance needs repairing, please contact your local AEG Service Force Centre. Electrical Connection Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person. WARNING – THIS APPLIANCE MUST BE EARTHED The manufacturer declines any liability should these safety measures not be observed. Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance rating plate. The rating plate is inside, on the left. The appliance is supplied with a 13 amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13 amp ASTA approved (BS 1362) fuse must be used. Important GREEN & YELLOW The wires in the mains lead are coloured in accordance with the following code: Green and Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: 1.The wire coloured green and yellow must be connected to the terminal marked with the letter “E” or by the earth symbol or coloured green and yellow....

Questo manuale è adatto anche per i modelli :
Frigoriferi - 66000I (427.83 kb)
Frigoriferi - 66000I (427.83 kb)
Frigoriferi - 66000I (427.83 kb)
Frigoriferi - 66000I (427.83 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie