It is too warm in the Thermostatic control can be set incor-Set the thermostat knob to higher freezer. rectly. position. The door does not close tightly or it is Check if the door closes well and the not shut properly. gasket is unhurt and clean. Products in big quantity to be frozen Wait some hours and then check the were put in. temperature again. Products to be frozen are placed too Place the products in a way so that closely to each other. cold air could circulate among them. Water flows at the It is normal. During automatic defrost- back plate in the ing frost melts on the back plate. refrigerator. The outlet of the chamber can be Clean the outlet. Water flows into the clogged up. chamber. Products placed in can prevent water Replace the products so that they can from flowing into the collector. not touch the back plate directly. Water flows onto the The melting water outlet flows not Put the melting water outlet to the floor. into the evaporative tray above the evaporative tray. compressor. There are too much Products are not wrapped properly. Wrap the products better. frost and ice. Doors are not shut properly or do not Check if the doors close well and the close tightly. gaskets are unhurt and clean. The thermostatic control can be set Set the thermostat knob to a position incorrectly. that gives higher temperature. Problem Possible cause Solution The compressor oper- The thermostatic control is set incor- Set the thermostat knob to a position ates continually. rectly. that gives higher temperature. Doors are not shut properly or do not Check if the doors close well and the close tightly. gaskets are unhurt and clean. Products in big quantity to be frozen Wait some hours and then check the were put in. temperature again. Too warm food was put in. Put food at max. room temperature. The appliance does Plug is not connected to the mains Check the connection. not work at all. socket properly. Neither cooling, nor The fuse burnt out. Change the fuse. lighting works. The thermostatic control is not on. Start the appliance according to instructions in chapter 'Putting it into use'. Electrical network broke down. Get an electrician to check it. The appliance is not supported proper- Check if the appliance stands stable The appliance is ly. (all the four feet should be on the noisy. floor). Inasmuch as the advice does not lead to result, call the nearest Service Force Centre. How to change the bulb Should the light fail to work you can change it as below: Disconnect from the electricity supply. Press the rear hook (1) of the lam pcover by a screwdriver and at the same time pull and rotate the cover in the direction indicated by the arrow (2). So the bulb can be replaced. (Bulb type: T25 Daylight 230-240 V, 25 W, E 14 thread) After changing the bulb replace the cover, snap it in place and reconnect the electricity supply. Electrical connection This refrigerator is designed to operate on a 230 V AC (~) 50 Hz supply. The plug must be put into a socke...

Questo manuale è adatto anche per i modelli :
Frigoriferi - 200372733 (224.49 kb)
Frigoriferi - 200372733 (224.49 kb)
Frigoriferi - 200372733 (224.49 kb)
Frigoriferi - 200372733 (224.49 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie