Log:
Ordina : Nome ↑   Scaricare   Valutazione   Size ↑  
Scaricare : 0   File Size : 217 kb   Produttore : Carrier  
Categoria : Frigoriferi
@name

7. Switch the appliance back on. Symptom Possible Cause Remedy Appliance is not switched on Switch on the appliance. Mains plug is not plugged in Insert mains plug. or is loose. Appliance does not work. Check fuse, replace if neces- Fuse has blown or is defective. sary. Mains malfunctions are to be Socket is defective. corrected by an electrician. Turn the temperature control Appliance cools too much. Temperature is set too cold. knob to a warmer setting. Temperature is not properly Please look

Scaricare : 0   File Size : 108 kb   Produttore : Carrier  
Categoria : Frigoriferi
@name

If this does not fix the leak, the connection must be reinstalled using a new ferrule and backup ring in the fitting. Contact your Carrier representative for assistance in locating these parts. After leak testing, evacuate, dehydrate, and recharge the circuit using an approved refrigerant recovery device. Correct type and amount of refrigerant are listed on unit nameplate and in base unit documentation. Fig. 2 — Installing Fittings and Valves, 30HX (Typical) 3 Fig. 3 — Installing Valves, 30GX St

Scaricare : 4   File Size : 529 kb   Produttore : Carrier  
Categoria : Frigoriferi
@name@name

Press the button (I) again for about 5 seconds. In the temperature indicator there is a "count down" i.e. a backward counting from "3" to "1". When "1" appears the refrigerator is turned off. The temperature indicator switches off. Switching the Appliance off To switch off, hold down the (A) button. If the appliance is not going to be used for an extended period: 1. Turn off the appliance. 2. Remove the mains plug or switch off or turn out the circuit breaker or fuse. 3. Defrost the freezer comp

Scaricare : 34   File Size : 440 kb   Produttore : Carrier  
Categoria : Frigoriferi
@name

FI 55985 and ending with Serial No. G448588. INDEX UNIT FIGURE DESCRIPTION VOLTS UNIT LABEL DIAGRAM 30HR,HS NUMBER 30HR Rev 070 1 WTri ngTor Part-Winding Start All - - 120 2 Suggested Field Wiring Interlocks All All Same As Below 3 '' 4 ‘ ' ‘ "Locations of 070, 080, 090 Control Components Power Schematic 208,230, 460,575 080-1214 080-1224 A 5 Control Li rcu i t (Simplified Schematic) 6 "7 Control Circuit 100, 110, 120 (Simplified Schematic) Power Schematic 208,23

Scaricare : 30   File Size : 3 mb   Produttore : Carrier  
Categoria : Frigoriferi
@name

04-53300054-01 Printed in U.S.A. Form 30MP-1SI Pg 1 910 1-10 Replaces: New Installation Instructions CONTENTS Page GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1,2 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-16 Location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Step 1 — Inspect Shipment . . . . . . . . . . . . . . . . . . .

Scaricare : 2   File Size : 365 kb   Produttore : Carrier  
Categoria : Frigoriferi
@name@name

However when the ice becomes very thick on the inner liner, complete defrosting should be carried out as follows: 1. Remove the frozen food from the freezer, wrap it in several layers of newspaper and put it in a very cool place. 2. Switch off the appliance and pull out the plug, or remove or unscrew the safety fuses. 3. Leave the freezer compartment door open. 4. Insert the plastic scraper into the recess provided under the defrost water channel and place a collec ting basin under it. 5. Once d

Scaricare : 1   File Size : 440 kb   Produttore : Carrier  
Categoria : Frigoriferi
@name

L. CONTACTS IF AVAILABLE CHILLED WATER COND. PUMP STARTER AUX. CONTACT OR FLOW SWITCH SHOULD BE FLOW SWITCH LOCATED HERE ONLY WHEN COND PUMP STARTER IS INDEPENDENT OF 30HR, HS WIRING. fio~|------0~ - FC i GO—---O— - -0 -0 CONTACTOR COILS FOR COND. FAN MOTORS WITH SEPARATE AIR COOLED COND. FOR EACH REFRIGERATION CIRCUIT. (SEE NOTES 5 AND 6) Fig. 2 — Suggested Field Wiring of Interlocks 0-----©-----0 CONTACTOR COIL FOR COND. WATER PUMP OR FOR FAN MOTOR(S) ON SINGLE TWO CIRCUIT AIR COOLE

Scaricare : 38   File Size : 108 kb   Produttore : Carrier  
Categoria : Frigoriferi
@name

30HX-900---009, 30GX-900---005 (50 or 60 Hz — 230-v Control) CONTENTS Page SAFETY CONSIDERATIONS ...................1 INTRODUCTION ..............................1 INSTALLATION ............................. 1-6 Step 1 — Examine Package Contents .........1 Step 2 — Install Piping .......................2 • REMOVE MINIMUM LOAD PORT PLUGS AND INSTALL FITTINGS • INSTALL PIPING • INSTALL BALL AND SOLENOID VALVES • CONNECT PIPING Step 3 — Dehydrate and Recharge Circuit .....3 Step 4 — Install Control W

Scaricare : 3   File Size : 224 kb   Produttore : Carrier  
Categoria : Frigoriferi
@name

-If the power cord is damaged, it must be replaced by a certified service agent or qualified service personnel. If the power plug socket is loose, do not insert the power plug. -There is a risk of electric shock or fire. You must not operate the appliance without the lamp cover of the interior lighting. When cleaning, defrosting, taking out frozen food or ice tray do not use sharp, pointed or hard devices, as they can cause damage to the appliance. Be careful not to allow liquids to leak into th

Scaricare : 32   File Size : 676 kb   Produttore : Carrier  
Categoria : Frigoriferi
@name

2 — Rigging with Spreader Bars (Field Supplied) Table 2 — Temperature Limits for Standard Units TEMPERATURE F C Maximum Ambient Temperature 125 52 Minimum Ambient Temperature 0 –18 Maximum Cooler EWT* 95 35 Maximum Cooler LWT 70 21 Minimum cooler LWT† 38 3.3 LEGEND EWT — Entering Fluid (Water) Temperature LWT — Leaving Fluid (Water) Temperature *For sustained operation, EWT should not exceed 85 F (29.4 C). †Unit requires modification below this temperature. MOUNTING UNIT — When unit is in proper





categorie