|
da questo dispositivo ha anche altre istruzioni :
Facilità d'uso
If charging takes longer than about six hours, a timer will terminate it automatically, even if the battery is not fully charged. This is indicated by the back lamp flashing red. If the battery has not been used for a very long time, charging may be terminated automatically and the back lamp may start flashing red after only about 45 minutes. In either case, disconnect the USB cable from the camera and then reconnect it to resume charging. Back Lamp Operation Back lamp USB cable (included with camera) Making sure that the 8 mark on the USB cable connector is towards the side opposite that of the monitor screen, connect the cable to the camera. [USB] port Small connector USB-AC adaptor Lamp Status Description Lit Red Charging Flashing Red Abnormal ambient temperature, USB-AC adaptor problem, or battery problem (page 109), or charging terminated by the timer Off Charging complete 6. After charging is complete, disconnect the USB cable from the camera and then unplug the power cord from the power outlet. Quick Start Basics 19 USB Cable Connection Precautions • When connecting the USB cable to the camera, make sure that the cable connector and monitor screen panel are oriented correctly as shown in the illustration below. Make sure that the 6 mark side of the USB cable connector and the front of the monitor screen panel (the side opposite that of the monitor screen) are facing in the same Front of monitor screen panel direction. The back lamp always initially light after charging starts. Even if the battery is already fully charged, the lamp will light momentarily. If the lamp does not light, check the orientation of the USB cable connector. • Note that even while the connector is fully inserted, you still will be able to see the metal part of the connector as shown in the illustration. . To charge using a USB connection to a computer The camera’s battery is charged whenever the camera is connected directly to a computer with the USB cable. • Depending on the setup of your computer, you may not be able to charge the battery over a USB connection. If this happens, use of the USB-AC adaptor that comes with the camera is recommended. IMPORTANT! • The first time you connect the camera to your computer with the USB cable, an error message may appear on your computer. If this happens, disconnect and then reconnect the USB cable. 1. Press [p] (Power) to turn off the camera. 2. Press the back of the monitor screen panel so the panel moves towards you, and open the frame (page 13). Quick Start Basics 20 [USB] port Large connector Small connector [USB] port Large connector Small connector 3. Hook your nail into the groove of the USB USB port cover port cover and pull the cover in the direction indicated by the arrow to open it. 4. With your computer USB cable USB port turned on, connect the (included with camera) camera to it. The camera’s back lamp will light red. After a short while, the camera will turn on automatically and the back lamp will light amber to indicate that charging has started. The back lamp will light green when charging is complete. Note, however, that some computer models or connection conditions can produce low supply capacity. If low supply capacity exists, charging will start without the camera turning on. This is indicated by the back lamp lighting red. The back lamp will go out in this case after charging is complete. • It takes about 260 minutes to bring a fully dead battery to a full charge. • A battery that has not been used for a long time or ambient temperature extremes can cause charging to take longer than normal. If charging takes longer than about six hours, a timer will terminate it automatically, even if the battery is not fully charged. This is indicated by the back lamp flashing red. If the battery has not been used for a very long time, charging may be terminated automatically and the back lamp may start flashing red or go out after only about 30 minutes to 45 minutes. In either case, use of the USB-AC adaptor that comes with the camera is recommended. • Note that even while the connector is fully inserted, you still will be able to see the metal part of the connector as shown in the illustration. Making sure that the 8 mark on the USB cable connector is towards the side opposite that of the monitor screen, connect the cable to the camera. Quick Start Basics 21 Back Lamp Operation Back lamp Lamp Status Description Lit Amber Charging Lit Red Charging in progress (Data transfer with computer not supported.) Flashing Red Abnormal ambient temperature, or battery problem (page 109), or charging terminated by the timer Flashing Red and Amber The battery is over-discharged. Battery charging over connection with a computer’s USB port cannot be performed for some reason. Use the USB-AC adaptor that comes with the camera to charge the battery. Lit Green Charging complete, or charging stopped 5. After charging is complete, disconnect the USB cable from the camera and then from the computer. N...