Log:
valutazioni - 2, GPA: 4 ( )

Istruzioni per l'uso GE, Modello SGL-T

Produttore : GE
File Size : 1.11 mb
File Nome : 14cd83cf-7266-4b1b-b272-b38dc25f17db.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


When checking pressure, be certain that all the equipment on the same gas line is turned to the "ON" position. 6. Make certain that new piping joints and connections have been made in a clean manner and have been purged, so that piping compound, chips, etc, will not dog pilots, valves, and/or controls. Use pipe joint sealant that is approved for use with liquified petroleum gas. 7. WARNING: Always check gas connections for leaks using soap solution or like means. DO NOT CHECK WITH OPEN FLAME. INSTALLATION CLEARANCES This unit must be installed in accordance with the following clearances in order to provide proper operation and servicing of the appliance. Also, it is recommended that unit be installed with sufficient clearances to provide for proper cleaning and maintenance. Minimum clearances are I" for the sides and 6" from back. 9110 REV^ 2 422-GZTE INSTALLATION 1. Carefully remove unit from carton or crate. Remove any packing material from unit On stainless steel panels, the protective material should be removed before the unit is installed. Z Set skillet in position where gas and electrical services are nearby. Comply with clearances stated on the specification sheet Ensure there is sufficient clearance between fry pan and back walL Check for overhead clearance to accommodate for hinged cover when in the raised position. 3. Level skillet by means of adjustable stainless steel feet Use a spirit level and level unit four ways; across front, back, and down left and right edges. Securely anchor the adjustable feet to the floor and seal joints with a silicone sealant 4. FOR YOUR SAFETY: Keep the appliance area free and dear of any combustible materials. ELECTRICAL CONNECTION A direct electrical connection is required at the terminal block located near the front side of unit The supply line will enter through the rear (or bottom) of the skillet Refer to specification sheet for the exact locations. For ease in attaching the supply lines there is a removable cover on the electrical housing. Feed wire through hole in the centre of the electrical housing and attach to the terminal block. IMPORTANT: This appliance must be electrically grounded in full accordance with local codes, or in the absence of local codes, with the Canadian Electrical Code C22.1 or with the National Electrical Code, ANSI/NFPA No. 70-1990 (whichever is applicable). GAS CONNECTION It is recommended that a sediment trap (drip leg) be installed in the gas supply line. If the gas pressure exceeds 14" water column, a pressure regulator must be installed, to provide a maximum of 14" water column gas pressure to the gas control valve. Connect the gas supply piping to the input side of the gas control valve. Location and pressure data are shown on the specification sheet Installation must be in accordance with local codes and/or the National Fuel Gas Code ANSI Z223.1-1988 (USA) or Installation Codes for Gas Burning Appliances and Equipment CANI B149.1 and B1492 (Canada). Use a gas pipe joint compound which is resistant to UP. gas. Test all pipe joints for leaks with soap and water solution. Ensure that the gas pressure regulator is set for the manifold pressure-indicated on the ga...

Questo manuale è adatto anche per i modelli :
Friggitrici - SGL-T (1.11 mb)
Friggitrici - SGL-T (1.11 mb)
Friggitrici - SGL-T (1.11 mb)
Friggitrici - SGM-T (1.11 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie