Log:
valutazioni - 2, GPA: 3 ( )

Istruzioni per l'uso Napoleon Fireplaces, Modello GS 28-P

Produttore : Napoleon Fireplaces
File Size : 786.97 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


4. If more than one length of liner needs to be used to reach the stove, couple them together as illustrated in FIGURE 17. Seal the joints using the same procedure as described above. The vent system must be supported approximately every 10 feet along a horizontal run. Use supports or equivalent non-combustible strapping to maintain the 1" clearance from combustibles. FIGURE 16 FIGURE 17 FIGURE 18 FIGURE 19 FIGURE 20 10 W415-0153 / A / 10.29.01 Ensure that the sealant is not visible on the exterior pipes once installation is completed. An optional decorative brass band is available for this use. (Standard with a GD175 kit). In the event that the venting must be disassembled, care must be taken to reseal the venting. MOBILE HOME INSTALLATION In Canada, mobile home installation may be vented horizontally or vertically. In the United States, it may only be installed vertically. See "Vertical Venting" or "Horizontal Air Terminal Installation" for installation. The fireplace is equipped with two 5/16" diameter holes located near each corner of the base. For mobile home installations, the fireplace must be fastened in place. Use #10 screws, inserted through the holes in the base to secure. It is recommended that the fireplace be secured in all installations. STOVE VENT CONNECTION 1. Attach the adjustable pipe to the last section of rigid piping. Secure with screws and seal. 2. Install the 4" aluminium flexible liner to the stove. Secure with 3 screws and flat washers. Seal the joint and screw holes using the high temperature sealant provided. 3. Run a bead of high temperature sealant around the inside of the air intake collar. Pull the adjustable pipe a minimum 2" into the air intake collar. Continue with "Gas Installation" Page 13 SEALANT SPEED SWITCH COMBUSTION AIR COVER PLATES & GASKETS 8" SWITCH ON/OFF 2" OVERLAP 11." VARIABLE SELF DRILLING SCREWS #8x1/2" HI-TEMP FIGURE 21 11 W415-0153 / A / 10.29.01 COMBUSTION AIR COVER PLATES & GASKETS INSTALLING 'B' VENT: Follow the instructions for "Wall and Ceiling Protection". ADAPTER INSTALLATION FIGURE 24 1. Remove the spill switch bracket from the rear of the adapter. 2. Gently pull the two wire terminals (located inside the 7" flue collar at the top of the stove) out approximately 8 inches. 3. Bring the wires through the lower hole in the adapter and out the spill switch opening. To pass the wires through the hole more easily, temporarily tape the two terminals together. 4. With the spill switch opening aligned to the back of the stove, push the crimped edge of the adapter into the stove flue collar. 5. Connect the wire terminals to the spill switch and resecure the bracket. 6. Secure the terminal block into place as shown with the screw supplied. 7. Unscrew the wire access cover plate from the rear right hand side of the firebox. Remove and discard the gasket. SEE FIGURE 25. Remove the knockout from the cover plate and insert the protective bushing. Pull both spill switch wires through the bushing taking up any slack. Replace the cover plate. Connect one wire end to the terminal block and the other end to terminal 1 of the gas valve. FIGURE 31. Connect the two wires running down the left side of the unit from the on-off switch to the remaining tab on the terminal block and to terminal 3 on the gas valve. CHIMNEY INSTALLATION THREE TYPES OF CHIMNEY SYSTEMS MAY BE USED WITH THIS STOVE: B-VENT SPECIFICS - MODEL GS28 FIGURES 22 SWITCH SPILL FIGURE 24 ADAPTER 'B' VENT ADAPTATIONS 1. Remove and discard the two combustion air cover plates and gaskets located on the rear panel of the unit. SEE FIGURE 23. 2. Replace the four screws per side to secure the rear panel to the unit. FIG. 23 FIGURE 25 TERMINAL BLOCK TERMINAL BLOCK WIRE ACCESS COVER PLATE For aesthetics, the adapter has been designed to accept 12 12 a standard matte black 7" stove pipe and the Napoleon decorative brass band (standard with the GS-150KT). Both are available from your Napoleon dealer. B-VENT MODEL GS28 ONLY: Attach the B-Vent label, shown below, in the control area of the appliance. ATTACH THIS LABEL IN THE CONTROL AREA OF THE FIREPLACE. THIS FIREPLACE HAS BEEN CONVERTED TO A ‘B’VENT MODEL. ATTACHEZ CET ETIQUETTE DANS LA REGION DE CONTROLE DU FOYER. CE FOYER A ETE CONVERTI A UN MODELE A SYSTEME D’EVACUATION ‘B’. COMBUSTION AIR A chimney venting this stove shall not vent any solid fuel burning appliance. For optimum performance it is recommended that all horizontal runs have a minimum . inch rise per foot. Any stove needs air for safe operation and must be installed in such a way that adequate combustion air is available. ADDING VENT SECTIONS: For ease of assembly, a 7" telescoping stove pipe may be installed over the 4" vent connection of the adapter. Add vent sections, twist locking (clockwise) securely, to the required height. The vent should extend, at least, 3 feet above its point of contact with the roof and, at least, 2 feet higher than any wall, roof or building within 10 feet. FIGURE 26. (Thi...

Questo manuale è adatto anche per i modelli :
Elettrico - GDS 28-N (786.97 kb)
Elettrico - GS 28-N (786.97 kb)
Elettrico - GDS 28-P (786.97 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie