|
Facilità d'uso
Cond) Airflow = 3325 cfm (5649 m3/h) Heating Capacity (High Temp.) = 110,000 (32.21) Heating Capacity (Low Temp.) = 71,000 (20.79) Compressor Power (High Temp) = 7.59 kW Compressor Power (Low Temp) = 6.60 kW Coeff. Of Perf. (High Temp) = 3.4 Coeff. Of Perf. (Low Temp) = 2.4 Outdoor Fan Power = 615 watts Indoor Fan Power = 1,030 watts Note: 1. Rated with 25 feet of 1-3/8" suction and 1/2" liquid line. SSP-PRC002-EN Performance Data (System) Table PD-11 — Gross Heating Capacities (MBh) TWA155B Heat Pump with TWE155B Air Handler At 5000 CFM (I-P) Outdoor Heating Capacity (BTUH/1000) At Total Power in Kilowatts At Temperature Indicated Indoor Dry Bulb Temperature Indicated Indoor Dry Bulb Temperature (°F) 60 70 75 80 60 70 75 80 -18 68.8 60.9 58.1 55.9 11.9 12.3 12.5 12.8 -13 71.2 64.2 61.7 59.9 11.9 12.3 12.6 12.9 -8 74.3 68.2 66.2 64.7 11.9 12.4 12.7 13.2 -3 78.2 73.2 71.6 70.5 11.9 12.5 12.9 13.4 2 83.0 79.0 77.8 77.0 11.9 12.7 13.1 13.7 7 88.7 85.7 84.8 84.4 12.0 12.9 13.4 14.0 12 95.5 93.2 92.6 92.4 12.2 13.1 13.7 14.3 17 103.3 101.6 101.2 101.1 12.3 13.4 14.0 14.7 22 112.1 110.9 110.6 110.6 12.5 13.6 14.3 15.1 27 121.8 120.9 120.7 120.6 12.8 14.0 14.7 15.5 32 132.5 131.7 131.4 131.2 13.1 14.3 15.0 15.8 37 143.4 142.6 142.2 141.8 13.3 14.7 15.4 16.2 42 154.8 153.9 153.3 152.7 13.6 15.0 15.8 16.6 47 167.0 165.7 165.0 164.1 14.0 15.4 16.1 17.0 52 179.9 178.2 177.2 176.1 14.3 15.7 16.5 17.3 57 193.3 191.2 189.9 188.6 14.6 16.1 16.9 17.7 62 207.2 204.5 203.0 201.4 15.0 16.4 17.2 18.0 67 221.3 218.2 216.4 214.5 15.3 16.8 17.6 18.4 72 235.8 232.2 230.3 228.2 15.7 17.2 18.0 18.8 Table PD-11 — Gross Heating Capacities (kW) TWA155B Heat Pump with TWE155B Air Handler At 8494 m3/h (SI) Outdoor Heating Capacity (kW) At Total Power in Kilowatts At Temperature Indicated Indoor Dry Bulb Temperature Indicated Indoor Dry Bulb Temperature (°C) 15.6 21.1 23.9 26.7 15.6 21.1 23.9 26.7 -27.8 20.1 17.8 17.0 16.4 5.5 6.0 6.2 6.5 -25.0 20.9 18.8 18.1 17.5 5.6 6.1 6.3 6.6 -22.2 21.8 20.0 19.4 19.0 5.7 6.2 6.5 6.7 -19.4 22.9 21.4 21.0 20.6 5.8 6.3 6.6 6.9 -16.7 24.3 23.1 22.8 22.6 5.9 6.5 6.7 7.0 -13.9 26.0 25.1 24.8 24.7 6.0 6.6 6.9 7.2 -11.1 28.0 27.3 27.1 27.0 6.2 6.7 7.0 7.4 -8.3 30.2 29.8 29.6 29.6 6.3 6.9 7.2 7.5 -5.6 32.8 32.5 32.4 32.4 6.5 7.0 7.4 7.7 -2.8 35.7 35.4 35.3 35.3 6.6 7.2 7.5 7.9 0.0 38.8 38.6 38.5 38.4 6.8 7.4 7.7 8.1 2.8 42.0 41.7 41.6 41.5 6.9 7.6 7.9 8.3 5.6 45.3 45.0 44.9 44.7 7.1 7.8 8.1 8.5 8.3 48.9 48.5 48.3 48.1 7.3 8.0 8.4 8.8 11.1 52.7 52.2 51.9 51.6 7.5 8.2 8.6 9.0 13.9 56.6 56.0 55.6 55.2 7.7 8.4 8.8 9.2 16.7 60.7 59.9 59.4 59.0 7.9 8.7 9.1 9.5 19.4 64.8 63.9 63.4 62.8 8.1 8.9 9.3 9.8 22.2 69.0 68.0 67.4 66.8 8.4 9.2 9.6 10.0 Correction Factors - Other Airflows“(Table Value Correction Factor = Value at new airflow) Airflow 4500 cfm 5500 cfm 7645 m3/h 9344 m3/h Heating Capacity x 0.99 x1.01 Compressor kW x 1.02 x 0.98 Values at ARI Rating Conditions of: 70F (21.1C) and 47/43F (8.3/6.1C)(High Temp.Cond.) 70F (21.1C) and 17/15F (-8.3/-9.4C)(Low Temp. Cond) Airflow = 5000 cfm (8495 m3/h) Heating Capacity (High Temp.) = 166,000 (48.60) Heating Capacity (Low Temp.) = 101,000 (29.57) Compressor Power (High Temp) = 11.67 kW Compressor Power (Low Temp) = 9.66 kW Coeff. Of Perf. (High Temp) = 3.2 Coeff. Of Perf. (Low Temp) = 2.2 Outdoor Fan Power = 1100 watts Indoor Fan Power = 2570 watts Note: 1.Rated with 25 feet of 1-3/8"" suction and 1/2"" liquid line." SSP-PRC002-EN Performance Data (System) Table PD-12 — Gross Heating Capacities (MBh) TWA200B Heat Pump with TWE200B Air Handler At 6675 CFM (I-P) Outdoor Heating Capacity (BTUH/1000) At Total Power in Kilowatts At Temperature Indicated Indoor Dry Bulb Temperature Indicated Indoor Dry Bulb Temperature (°F) 60 70 75 80 60 70 75 80 -18 42.4 79.1 84.7 87.4 11.5 15.4 16.6 17.6 -13 68.2 86.2 90.2 92.3 13.0 15.6 16.7 17.7 -8 81.5 93.8 96.7 98.0 13.6 15.9 16.9 17.9 -3 93.1 101.8 103.7 104.5 14.1 16.2 17.1 18.1 2 104.2 110.2 111.4 111.7 14.5 16.4 17.4 18.3 7 115.2 119.2 119.8 119.7 14.9 16.7 17.6 18.6 12 126.6 128.8 128.9 128.5 15.2 17.0 17.9 18.9 17 138.2 139.1 138.8 138.2 15.5 17.3 18.2 19.2 22 150.3 150.1 149.5 148.6 15.9 17.6 18.6 19.6 27 162.9 161.8 160.9 159.8 16.2 18.0 18.9 20.0 32 176.1 174.3 173.2 171.9 16.5 18.3 19.3 20.4 37 189.2 186.9 185.6 184.3 16.9 18.7 19.7 20.8 42 202.8 200.0 198.6 197.2 17.2 19.1 20.2 21.3 47 216.9 213.8 212.3 210.8 17.6 19.5 20.6 21.8 52 231.9 228.5 226.8 225.3 18.0 20.0 21.1 22.3 57 247.4 243.6 241.9 240.3 18.4 20.5 21.7 22.9 62 263.2 259.1 257.2 255.6 18.9 21.0 22.2 23.5 67 279.3 274.8 272.8 271.0 19.4 21.6 22.8 24.1 72 295.9 291.1 289.0 287.0 20.0 22.2 23.4 24.7 Table PD-12 — Gross Heating Capacities (kW) TWA200B Heat Pump with TWE200B Air Handler At 11340 m3/h (SI) Outdoor Heating Capacity (kW) At Total Power in Kilowatts At Temperature Indicated Indoor Dry Bulb Temperature Indicated Indoor Dry Bulb Temperature (°C) 15.6 21.1 23.9 26.7 15.6 21.1 23.9 26.7 -27.8 12.4 23.2 24.8 25.6 5.5 6.0 6.2 6.5 -25.0 20.0 25.3 26.4 27.0 5.6...
Questo manuale è adatto anche per i modelli :Elettrico - TWA075A (3.65 mb)
Elettrico - TWA200B (3.65 mb)
Elettrico - TWE200B (3.65 mb)