Throw distance values at other terminal velocities may be established by multiplying throw distances in table above by throw factor: Terminal Velocity Throw Factor 50 fpm (.25 m/s) x 1.50 100 fpm (.51 m/s) x .75 150 fpm (.76 m/s) x .50 Table PD-24— Static Pressure Drop Through Accessories (Inches Of Water Column)1 —Air Handler Discharge Electric Heaters (kW) Unit Return Grille Plenum and Grille2 5-10 15-20 25-30 35-50 Model No. CFM m3/h In. wc1 Pascal In. wc1 Pascal In. wc (Pascal) 1400 2380 .09 (22.4) .16 (39.8) .06 (15.0) .06 (15.0) .12 (29.9) — TWE050A 1600 2718 .12 (29.9) .21 (52.3) 08 (19.9) .08 (19.9) .14 (34.9) — 2000 3398 .18 (44.8) .33 (82.2) .13 (32.4) .13 (32.4) .19 (47.3) — 2100 3568 .05 (12.5) .19 (47.3) .02 (5.0) .03 (7.5) .05 (12.5) .08 (19.9) TWE075A 2400 4079 .08 (19.9) .27 (67.2) .03 (7.5) .06 (15.0) .08 (19.9) .12 (29.9) 3000 5098 .13 (32.4) .40 (99.6) .06 (15.0) .12 (29.9) .17 (42.4) .23 (57.3) TWE100A 2800 4756 .04 (10.0) .34 (84.7) .03 (7.5) .04 (10.0) .14 (34.9) .20 (49.8) TWE100B 3200 5436 .07 (17.4) .43 (107.1) .06 (15.0) .13 (32.4) .19 (47.3) .26 (64.8) 4300 7304 .07 (17.4) .18 (44.8) .02 (5.0) .02 (5.0) .04 (10.0) .05 (12.5) TWE155B 4800 8154 .09 (22.4) .23 (57.3) .03 (7.5) .03 (7.5) .06 (15.0) .08 (19.9) 6000 10195 .15 (37.4) .34 (84.7) .06 (15.0) .06 (15.0) .12 (29.9) .17 (42.4) 5600 9515 .07 (17.4) .32 (79.7) .04 (10.0) .04 (10.0) .10 (25.0) .15 (37.4) TWE200B 6400 10872 .11 (27.4) .43 (107.1) .06 (15.0) .06 (15.0) .13 (32.4) .19 (47.3) 8000 13594 .17 (42.3) .66 (164.3) .10 (25.0) .10 (25.0) .20 (49.8) .30 (74.7) 1. Return air filter ESP included in Fan Performance Table data. 2. At louver opening angle of 42°F (5.5°C). For ESP at other angle openings, see accessory Installer’s Guide. SSP-PRC002-EN Performance Data Table PD-25 — Auxiliary Electric Heat Capacity — Air Handler No. Stage 1 Stage 2 Total Unit Total of kW Btu kW kW Btu kW Btu kW Model No. kW Stages Input Output Output Input Output Output Output Output TWE050, 075,100 3.47 1 3.47 11,851 3.47 — — — 11,851 3.47 6.92 1 9.92 23,606 6.92 — — — 23,606 6.92 10.39 1 10.39 35,457 10.39 — — — 35,457 10.39 17.31 2 10.39 35,457 10.39 6.92 23,606 6.92 59,063 17.31 TWE075, 100A, 100 24.22 2 13.83 47,213 13.83 10.39 35,457 10.39 82,670 24.22 TWE155, 200 6.94 1 6.94 23,701 6.94 — — — 23,701 6.94 13.83 1 13.83 47,213 13.83 — — — 47,213 13.83 20.78 2 13.83 47,213 13.83 6.94 23,701 6.94 70,915 20.78 34,62 2 20.78 70,915 20.78 13.84 47,213 13.89 118,128 34.61 *Heaters are rated at 400v. For other than rated voltage, Voltage Voltage 2 2 Capacity = x Rated Capacity and kW = x Rated kW. (Rated Voltage ) ( Rated Voltage ) SSP-PRC002-EN Electrical Data Table ED-1— Electrical Characteristics — Motors — Air Handler Standard Fan Motor Oversized Fan Motor Unit Amps Amps Model No. Volts Phase FLA LRA Phase FLA LRA TWE050 380/415 3 1.4 8.2 3 1.8 21.6 TWE075 380/415 3 3.2 19.7 3 4.0 25.5 TWE100 380/415 3 3.6 25.5 3 5.3 37.5 TWE155 380/415 3 4.6 37.5 3 6.9 39.2 TWE200 380/415 3 7.6 39.2 3 9.0 65.1 Table ED-2 — Unit Wiring — Air Handler Minimum Maximum Fuse Unit Model No. Unit Operating Voltage Range Circuit Ampacity Size or Maximum Circuit Breaker TWE050 380/415 2 15 TWE075 380/415 4 15 TWE100 380/415 5 15 TWE155 TWE200 380/415380/415 6 10 15 15 Table ED-3— Electrical Characteristics — Motors — 50 Cycle — Heat Pumps Compressor Motor Condenser Fan Motor Amps Amps Unit RLA LRA FLA LRA Model No. No. Volts Phase (Ea.) (Ea.) No. Volts Phase (Ea.) (Ea.) TWA075AD TWA100AD TWA155BD TWA200BD 1 1 2 2 380/415 3 8.8 90.0 380/415 3 15.8 124.0 380/415 3 11.2 94.8 380/415 3 15.8 1 2 4 .0 1 1 2 2 380/415 1 1.6 3.7 380/415 1 2.7 7.0 380/415 1 1.6 3.7 380/415 1 2.7 7.0 Table ED-4 — Unit Wiring — Heat Pumps Minimum Maximum Fuse Unit Model No. Unit Operating Voltage Range Circuit Ampacity Size or Maximum Circuit Breaker TWA075 380/415 12.6 50 TWA100 380/415 22 .5 35 TWA155 TWA200 380/415 380/415 28.4 41.0 35 50 SSP-PRC002-EN Electrical Data Table ED-5— Unit Wiring With Electric Heat (Single Point Connection) — Air Handlers Heater Heater To Use Control Minimum Maximum Model No. kW Rating1 with Unit Stages Circuit Ampacity 2 Fuse Breaker Size 2 BAYHTRL405A 3.47 1 9 15 BAYHTRL410A 6.92 TWE050AD 1 17 20 BAYHTRL415A 10.39 1 24 25 BAYHTRL425A 17.31 2 39 40 BAYHTRL405A 3.47 1 11 15 BAYHTRL410A 6.92 1 18 20 BAYHTRL415A 10.39 TWE075AD 1 26 30 BAYHTRL425A 17.31 2 41 45 BAYHTRL435A 24.22 2 56 60 BAYHTRL405A 3.47 1 12 15 BAYHTRL410A 6.92 1 19 25 BAYHTRL415A 10.39 TWE100AD, TWE100BD 1 27 30 BAYHTRL425A 20.78 2 42 45 BAYHTRL435A 24.22 2 57 60 BAYHTRM410A 6.94 1 21 30 BAYHTRM420A 13.83 TWE155BD 1 36 40 BAYHTRM430A 20.78 2 51 60 BAYHTRM450A 34.62 2 81 90 BAYHTRM410A 6.94 1 25 40 BAYHTRM420A 13.83 TWE200BD 1 40 50 BAYHTRM430A 20.78 2 55 60 BAYHTRM450A 34.62 2 85 90 1. kW ratings are at 400v for 3 phase, 400v air handlers Voltage Voltage 2 2 For other than rated voltage, ampacity = x Rated Capacity and kW = Rated kW. (Rated Voltage) (Rated Voltage ) 2. Any power supply and circuits must...
Questo manuale è adatto anche per i modelli :Elettrico - TWA075A (3.65 mb)
Elettrico - TWA200B (3.65 mb)
Elettrico - TWE050A (3.65 mb)