Log:
valutazioni - 4, GPA: 4 ( )

Istruzioni per l'uso Bryant, Modello 580D

Produttore : Bryant
File Size : 1.36 mb
File Nome : pds580d.36.8~1.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


INTEGRATED GAS UNIT CONTROLLER (IGC) (All Models) — All ignition components are contained in the compact IGC which is easily accessible for servicing. The IGC control board, designed and manufactured exclusively for Bryant rooftop units, provides built-in diagnostic capability. An LED (light-emitting diode) simplifies troubleshooting by providing visual fault notification and system status confirmation. The IGC also contains an exclusive anti-cycle protection for gas heat operation. After 4 continuous cycles on the unit high- temperature limit switch, the gas heat operation is disabled, and an error code is issued. This feature greatly improves reliability of the rooftop unit. Form No. PDS 580D.36.8 The IGC also contains burner control logic for accurate and dependable gas ignition. The LED is visible without removing the unit control box access panel. This LED fault-notification system reduces service person troubleshooting time and minimizes service costs. The IGC also maximizes heating efficiency by controlling evaporator-fan on and off delays. QUIET, EFFICIENT OPERATION AND DEPENDABLE PERFORMANCE — Compressors have vibration isolators for extremely quiet operation. Efficient fan and motor design permits operation at very low sound levels and all 580D036-150 units are mounted either on independent mounting rails (036-072) or on an exclusive polycore plate (090-150). The 580D090-150 and 579F180-300 units offer high energy efficiency and lower utility costs through part-load operation using 2 stages of cooling. Quiet and efficient operation is provided by belt-driven evaporator fans (standard on all units over 5 tons). The belt-driven evaporator-fan is equipped with variable-pitch pulleys which allow adjustment within the rpm ranges of the factory-supplied pulleys. A standard (low-medium static) and alternate (high static) drive is available for 579F180-300 units. Increased operating efficiency is achieved through computer- designed coils featuring staggered internally enhanced copper tubes. Fins are ripple-edged for strength, lanced, and double waved for higher heat transfer. Tubular, dimpled gas heat exchangers optimize heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air. The dimpled design creates a turbulent gas flow to maximize heating efficiency. The extra thick Alumagard™ heat exchanger coating provides corrosion resistance and ensures long life. The California Air Quality Management Districts NOx requirement of 40 nanograms/joule or less is met when low NOx kit CRLOWNOX001A00 is installed for sizes 036-060. The unsightly appearance of flue stacks is eliminated and the effects of wind on heating operations are diminished by the induced draft combustion system. The inducer fan draws hot combustion gas through the heat exchanger at the optimum rate for the most effective heat transfer. The heat exchanger operates under negative pressure, preventing flue gas leakage into the indoor supply air. During the heating mode, the evaporator-fan relay automatically starts the evaporator fan after the heat exchanger warms up to a suitable temperature. The 30-second fan delay prevents cold air from entering the supply duct system when the conditioned space is calling for heat to maximize efficiency. The direct-spark ignition system saves operating expense when compared to pilot ignition systems. No crossover tube is required, therefore no sooting or pilot fouling problems can occur. All 580D and 579F standard units are designed for natural gas, but an accessory LP (liquid propane) conversion kit is available, if required. SAFETY IS BUILT IN — All 580D and 579F units have a flame rectification sensor to quickly sense the burner flame and ignite burners almost immediately. Fast shutdown is a certainty since the sensor reacts quickly to any flame outage or system failure. In the event of a shutdown, an error code is issued at the IGC board. Safety is also assured due to the heating safety controls which will shut down the unit if there is a problem. If excessive temperatures develop, limit switches shut off the gas valve. After 4 continuous short cycles of the high-temperature limit switch, the IGC board locks out the gas heat cycle to prevent any further short cycles. This safety feature is provided exclusively on Bryant rooftop units. The rollout switch also deenergizes the gas valve in the event of a flame rollout. DURABLE, DEPENDABLE CONSTRUCTION— Designed for durability in any climate, the weather-resistant cabinets are constructed of galvanized steel and bonderized, and all exterior panels are coated with a prepainted baked enamel finish. The paint finish is non-chalking, and is capable of withstanding ASTM B117 500-hour Salt Spray Test. All internal cabinet panels are primed, permitting longer life and a more attractive appearance for the entire unit. In addition, the 580D090-150 units are designed with a single, continuous top ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie