Log:
valutazioni - 4, GPA: 3.3 ( )

Istruzioni per l'uso Lennox International Inc., Modello MERIT PLUS MPB4540CNM-B

Produttore : Lennox International Inc.
File Size : 2.39 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


(406 mm) from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the 16 in. (406 mm) must be measured from the drywall surface. It is important that this dimension be exact. Headers may be in direct contact with the appliance top standoff spacers, but must not be supported by them or notched to fit around them. All construction above the appliance must be self-supporting. DO NOT use the appliance for structural support. Secure the fi replace to the side framing members using the unit’s nailing fl anges — one top and bottom on each side of the fi replace front (See Figure 7). Use 8d nails or their equivalent. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. FLOOR NAILING TABS Fireplace may be anchored to fl oor. Bend down two anchor tabs (one on each side) located at the base of the fi replace and secure to the fl oor by nailing with 8d nails or equivalent (see Figure 8). Anchor Tab Figure 8: Floor Anchor Tabs Note: Some units only have one anchor tab on each side. Figure 7: Unit Secured to Framing by Nailing Flange Note: The nailing flanges, combustible members and screw heads located in areas directly adjacent to the nailing flanges, are EXEMPT from the 1/2” clearance to combustible requirements for the firebox outer wrapper. Combustible framing may be in direct contact with the nailing flanges and may be located closer than 1/2” from screw heads and the firebox wrapper in areas adjacent to the nailing flanges. Frame the opening to the exact dimensions specified in the framing details of this manual. Side Framing Unit Nailing Flange(No clearance tocombustible framing is required) Left Side Front Corner of Fireplace Shown (Right Side Requirements the Same) LENNOX HEARTH PRODUCTS • MERIT PLUS® B-VENT GAS FIREPLACES (MPB33/35/40/45) • INSTALLATION INSTRUCTIONS Header B Back Wall of Chase/Enclosure Including Finishing Materials *Optional FOAKOutside Air Kit A G C J if any Rough Framing Face(Unfinished Shown) Outside Chase A Back Wall of Chase/EnclosureIncluding Finishing Materials Fireplace Framing if any Back Wall of Chase/EnclosureIncluding Finishing Materialsif any K D C A E G F Rough RoughFraming FaceInside Chase (Unfinished Shown) C A G H H Framing Face Corner Installation (Unfinished Shown) All framing dimensions calculated for 1/2" dry wall at the appliance face. If sheathing the chase or finishing with other thickness materials, calculations will need to be made. * Outside air kit - FOAK (without adaptor). See Figure 22 on Page 16. Model No. A Unit Size A Framing Size B C D E F G H J K MPB33 in. mm 842 33-1/8 845 33-1/4 845 33-1/4 546 21-1/2 286 11-1/4 1232 48-1/2 616 24-1/4 330 13 102 4 103 4-1/16 872 34-5/16 MPB35 MPB40 MPB45 in. mm in. mm in. mm 35-1/8 892 40-1/8 1019 - 1146 45-1/8 35-1/4 895 40-1/4 1022 45-1/4 1149 35-1/4 895 40-1/4 1022 40-1/4 1022 24-7/8 29-7/8 34-7/8 886 759 632 - - - 12-3/4 14-11/16 17-3/16 437 373 324 57-1/2 1460 61-13/16 1570 6...

Questo manuale è adatto anche per i modelli :
Camini - MERIT PLUS MPB3328CNE-B (2.39 mb)
Camini - MERIT PLUS MPB4540CNE-B (2.39 mb)
Camini - MERIT PLUS MPB4035CNM-B (2.39 mb)
Camini - MERIT PLUS MPB4035CNE-B (2.39 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie