Log:
valutazioni - 5, GPA: 4.2 ( )

Istruzioni per l'uso Lennox Hearth, Modello EBVCLNM

Produttore : Lennox Hearth
File Size : 898.38 kb
File Nome : 22870edb-c559-4bba-87b4-c1195b98e4e6.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


WARNING: DO NOT USE ABRASIVE CLEANERS. NEVER CLEAN THE GLASS WHEN IT IS HOT. CAUTION: DO NOT TOUCH THE FRONT ENCLOSURE GLASS WITH YOUR HANDS WHILE THE FIREPLACE IS IN USE. Outside Combustion Air Controls Many appliances are equipped, when installed, with an outside (make-up air) vent system that is designed to provide the appliance with outside make-up air for combustion when in operation. The outside air control lever for the outside air system is standard on all appliances but should not be operated if the complete system is not installed. Refer to Figure 4. When the complete outside air vent system is installed, the installer will remove the securing screw from the combustion air control lever located on the right side (EBVST, EBVPF and EBVCL), or left side (EBVCR) of the fireplace opening. If the securing screw has not been removed and you have reason to believe that you have a complete outside air system, contact your distributor to have your appliance inspected for the presence of the complete system. DO NOT assume that you have this system in place. Outside Air Control Lever with Stop Behind Securing Screw Outside Air Shutter in the Closed Position Control Compartment Access Panel Outside Air Control Lever and Securing Screw Location (EBVST, EBVPF and EBVCR Units Shown) Figure 4 WARNING: DO NOT OPERATE THE SHUT- OFF LEVER UNLESS A COMPLETE OUTSIDE COMBUSTION AIR SYSTEM HAS BEEN IN- STALLED WITH YOUR APPLIANCE. To open the outside air shutter, open the botttom control access panel, reach into the gap between the firebox bottom and the modesty panel, and pull the outside air control lever all the way out. The outside air shutter should be fully open when the fireplace is in use and completely closed when the fireplace is not being used. Closing it when not in use will prevent outside cold air from entering the dwelling. Venting Action and Safety Limit Operation If you suspect that the appliance is not venting properly, or you notice windows fogging or sweating, you may want to conduct the following spillage test: 1 -Place unit in its normally-operated condition, that is, with the glass enclosure panels in place. 2 -Close all doors and windows in the room. Turn on all exhaust fans in the house. 3 -Light the appliance. 4 -Wait 15 minutes. 5 -To check for venting action, start by holding a smoke producing device within an inch of one edge (side edge, not top or bottom edge) of one glass enclosure panel. The smoke should be drawn toward the edge of the glass enclosure panel. Continue the test by moving the smoke producing device along the entire length of both side-edges of the glass door. Repeat the test for all glass enclosure panels. 6 -If the smoke is not drawn towards the edges of the glass door turn off the appliance and call a qualified service technican. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Manual-Reset Safety Limit Switch This appliance is equipped with a manual- reset blocked flue safety limit switch. Refer to Figure 5for its location. If, during appliance operation, the flame goes out (independently of the burner on/off wall switch), it may be due to the operation of this safety limit switch. First allow the appliance to cool, then reset the safety switch by pushing the red reset button on it. A - To access the blocked flue safety switch when top radiant panel is not covered with non-combustible material: 1 Lift up and remove top radiant panel/ eyebrow assembly on the control side of unit. 2 Reach between the cabinet side and the firebox side wall and locate the blocked flue safety switch. 3 Push the red reset button on the switch. The applilance should then relight and remain lit. If this does not occur, turn off the appli- ance and call a qualified service technician. Figure 5 B - To access the blocked flue safety switch when top radiant panel is covered with noncombustible material: Note: This procedure should only be performed by a qualified service technician. 1 Lower bottom hinged panel on the control side of the fireplace. Remove the glass enclosure panel as described on page 8, under "Remove the front glass enclosure panel as follows:", Steps 2, 3, 4, 5 and 6. 2 Remove the side baffle securing screws (5) and then remove the baffle. 3 Remove the safety switch bracket securing screws (2), and pull the switch/bracket assembly through the side panel slot. 4 Push the red reset button on the switch. 5 Reinstall the switch/bracket assembly. 6 Reinstall the side baffle. 7 Reinstall front glass door. 8 Raise the bottom hinged panel. The appliance should then relight and remain lit. If this does not occur, check unit for a blocked flue condition. SAFETY SWITCH LOCATION (EBVCL SHOWN) EVBST and EBVPF Safety Switch Location Also as Shown; EBVCR Location on Left End of Fireplace. MANUALLY-RESET SAFETY LIMIT SWITCH FIREBOX SIDE BAFFLE FIREBOX SIDE BAFFLE SECURING SCREW FIREBOX BOX SIDE WALL CABINET SIDE WALL TOP RADIANT PANEL AND EYEBROW SAFETY SWI...

Questo manuale è adatto anche per i modelli :
Camini - EBVCLPM (898.38 kb)
Camini - EBVCRNE (898.38 kb)
Camini - EBVCRNM (898.38 kb)
Camini - EBVCRPM (898.38 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie