|
Facilità d'uso
The modesty panel mounted ON-OFF control switch is located behind the control compartment access panel, below the appliance front glass enclosure panel. See Figure 1. Piezo Ignitor Gas Valve ModestyPanel Control Compartment Access panelON/OFF Switch HingePin Modesty Panel Lock Slot Control Compartment Access Millivolt Control Valve Shown Figure 1 Manifold Pressure Port ON/OFF Switch 4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 2 Note: The piezo ignitor is located on the modesty panel - see Figure 1. To ease door closure, depress the catch to place it in its retracted position, then close the door. Operation of millivolt and electronic gas control systems are different. Before lighting and operating your appliance determine if you have a millivolt or electronic appliance. Refer to Figure 1 on page 3 for access to the gas control valve. Millivolt appliances will be fitted with the gas control valve shown in Figure 2. Appliances with electronic systems will be fitted with the electronic valve shown in Figure 3. Familiarize yourself with the gas control valve that your appliance uses. Millivolt Appliances - To light millivolt appliances refer to the detailed lighting instructions found on page 14 (English) and page 15(French). Millivolt ap- pliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. Millivolt appliances are fitted with a burner ON/ OFF control switch (rocker switch). SeeFigure 1 on page 3for its location. Once the pilot is lit, the ON/OFF rocker switch will control the appliance ON/OFF operation. To operate: Toggle the switch between its ON and OFF positions. HI LOW TPTH TP TH PILOT PILOTON it OFF Variable Flame Height Adjustment Manifold Pressure Port Inlet Pressure Port Main Gas Control Knob IN OUT SIT Millivolt Gas Valve Gas Controls/Control Compartment Access The gas controls can be found behind the control compartment access panel. To open the control compartment access panel, actuate the spring-loaded magnetic catch securing the panels right side, by gently depressing the outer top corner of the panel until the catch "pops" the door free, allowing it to swing out and down to open. On millivolt systems, the piezo ignitor, Hi/Lo flame adjustment knob, and pilot and main gas ON/OFF control knob are located on the modesty panel. On both millivolt and electronic systems the gas valve is located behind the modesty panel. Refer to Figure 1. Once the control compartment access panel has been opened, the modesty panel can be removed as follows: pull the bottom edge of the modesty panel out of the locking slots of the cabinet bottom. Then tilt the top edge of the panel at a 45° angel and gently lift the panel out. Remove the modesty panel carefully, so that none of the wires become loose or disconnected. Now complete access to the gas control valve and its related controls is attainable. Honeywell Electronic Gas Valve Electronic Gas Control Valve Inlet Pressure Port OFFINPSI ONCONTROL IGNITER Figure 3 If your millivolt appliance is equipped with an optional wall-mounted ON/OFF switch or remote control kit and the pilot is lit, the appliance main burner may be turned on and off with the wall switch or remote control. Electronic Appliances To light electronic appliances refer to the detailed lighting instructions found in both English and French on pages 16 and 17of these instructions respectively.Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. Electronic appliances are fitted with a ON/OFF burner control switch (rocker switch). See Figure 1 on page 3for its location. The electronic system will go through the whole lighting sequence automatically once the rocker switch is toggled to the ON position. If your electronic appliance is equipped with an optional wall-mounted ON/OFF switch or remote control kit the appliance main burner may be turned on and off with the wall switch or remote control. Variable Flame Height Adjustment ( Millivolt Appliances only) 1. All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings while the appliance is in operation. Adjust the flame height as desired after lighting the appliance by rotating the variable adjustment control knob located on the front of the valve (refer to Figure 2). (An extension is provided to this knob so that the adjustment may be made at the modesty panel.) 2. When lit for the first time, this appliance will emit a slight odor for 14 hours. This is due to the “burn-in” of internal paints and lubricants used in the manufacturing process. 3. Keep lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is important that control compartments, burners...
Questo manuale è adatto anche per i modelli :Camini - EBVCLNM (898.38 kb)
Camini - EBVCLPM (898.38 kb)
Camini - EBVCRNM (898.38 kb)
Camini - EBVCRPM (898.38 kb)