Log:
valutazioni - 3, GPA: 5 ( )

Istruzioni per l'uso Napoleon Fireplaces, Modello SSBV-3530CNM

Produttore : Napoleon Fireplaces
File Size : 4.4 mb
File Nome :
Lingua di insegnamento: enfr
Vai a scaricare



Facilità d'uso


The Homeowner must contact a qualified service technician at once if any abnormal condition is observed. Small Area Paint Touch-up The finish of the appliance is a high quality powdercoat. Only use factory supplied powdercoat paint kit for touch-ups. Paint is available at your local authorized Superior Hearth Products dealer, cat. no. 90L74. Never attempt to paint a hot fireplace. Do not attempt to repaint the appliance until the finish is completely cured (see Burn-In Period on Page4). Ifthesurfacelaterbecomesstained or marred, it may be lightly sanded and touched up with spray paint. VENT SPILLAGE TEST After appliance installation, then periodicly thereafter, perform this spillage test to verify that proper venting conditions exist: 1 -Ensure glass enclosure panel is properly installed. 2 -Close all doors and windows in the room. Turn on all exhaust fans in the house. 3 -Light the appliance. 4 -Wait 15 minutes. 5-Tocheckforventingaction,startbyholding a smoke producing device within an inch of one edge (side edge, not top or bottom edge) of one glass enclosure panel. The smoke should be drawn toward the edge of the glass enclosure panel. Continue the testbymovingthe smoke producingdevice along the entire length of both side-edges of the glass door. 6 -Ifthesmokeisnotdrawntowardstheedges of the glass door, turn off the appliance and call a qualified service technican. Manually-Reset Spill Switch (limit disc) ALLOW APPLIANCE TO COOL COMPLETELY BEFORE ACCESSING AND RESETTING This appliance is equipped with a manually-reset blocked flue spill switch (limit disc). Refer to Figure 6 for the location. If, during appliance operation, the flame goes out (independently of the burner on/off wall switch), it may be due to the operation of this spill switch (limit disc). First allow the appliance to cool. Remove top louver panel. Then reset the spill switch (limit disc) by pushingtheredresetbutton,locatedbetweenthe wire terminals, on the back of the switch. The appliance should then relight and remain lit. Reinstall top louver panel. If the appliance doesnot relight, turn off the appliance and call for a qualified service technician. To replace the blocked flue spill switch (limit disc) refer to Figures 6, 7 & 8: NOTE -This procedure should only be performed by a qualified service technician. Important -Turn electrical power off before beginning this procedure. 1 - Remove the top louvered panel and the bottom control compartment panel (see Figure 1 on Page 4). Remove the glass enclosure panel (see Removing Glass Enclosure Panel on Page 7). -Remove the lintel securing screws (3) and thenremovethelintel.Oneofthelintelcabinet top holes is shown in Figure 7). -Removethescoopsecuringscrews(3)and then remove the scoop. See Figure 7. 4 -Remove the spill switch bracket securing screws (2), and pull the switch/bracket assembly,withlowvoltagewiresattached, throughthesidepanelslotintothefirebox. See Figure 8. 5 - Replace the spill switch. 6 - Reinstall the switch/brac...

Questo manuale è adatto anche per i modelli :
Camini - SSBV-3530CNE (4.4 mb)
Camini - SSBV-3530CNE (4.4 mb)
Camini - SSBV-3530CNM (4.4 mb)
Camini - SSBV-3530CNE (4.4 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie