Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso Empire Comfort Systems, Modello BVP42FP32

Produttore : Empire Comfort Systems
File Size : 4.27 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


3. Connect female terminal from receiver onto 120 VAC hot terminal on control module. 4. Connect remaining wire from remote control (male terminal) to (female terminal) on power cord removed from control module (step 2). 5. Insert electric remote control power cord plug into the junction box on the right side of fireplace. 6. Connect 3-prong plug into receptacle. See wiring diagram on page 34. Figure 24 DIRECT IGNITION WIRING DIAGRAM OPTIONAL REMOTE CONTROL (120V DIRECT IGNITION) Page 24 19400-3-0406 A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance • Do not touch any electrical switch • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. • Follow the gas supplier's instructions. • If you can not reach your gas supplier, call the fire department. B. Use only the wall switch or remote control switch to turn the gas control on/off. Any attempted repairs or adjustments should be performed by a qualified service technician. Applying force or attempted repair may result in a fire or explosion. C. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. TO TURN OFF GAS TO APPLIANCE 1. STOP! Read the safety information above. 2. Turn off all electric power to the appliance. 3. Open bottom louver assembly, or open the valve access door. 4. Turn gas line valve to "OFF." 5. Close bottom louver assembly, or close valve access door. 1. STOP! Read the safety information above. 2. Turn off all electric power to the appliance. 3. This appliance is equipped with an ignition device that automatically lights the burner. Do not try to light the burner by hand. 4. Open bottom louver assembly, or open valve access door. 5. Turn gas line valve to "ON." 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "A" in the safety information on reverse. If you do not smell gas, go to the next step. 7. Close bottom louver assembly, or close hearth access plate. 8. Turn on all electric power to the appliance. 9. If the appliance will not operate, follow the instructions "TO TURN OFF GAS TO APPLIANCE," and call your service technician or gas supplier. ON OFF DIRECT IGNITION LIGHTING INSTRUCTIONS INITIAL START UP GAS LINE PURGE NOTE: UNIT MUST BE PROPERLY GROUNDED FOR ELECTRONIC IGNITION TO FUNCTION. On initial installation, or after extended periods where the fireplace has not been used, gas lines may require purging. DIRECT IGNITION TROUBLESHOOTING With proper installation and maintenance, your new Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the troubleshooting guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken. Refer to page 24 for initial startup and GAS Line purge instructions. SYMPTOM CHECK ACTION No spark when system is turned to “ON” and reset cycle* has been completed. Check for 120V between black “hot” line at control module and “white” return at module. If 120V not present, check fuse or circuit breaker or repair wiring leading to fireplace. Spark for six (6) seconds at ignitor, but no ignition of burner. a. Check that gas is turned on and system purged. Turn gas on and/or purge system. b. Check that tips of ignitor are directly above ports on main burner. Spark is between electrodes and not from one electrode to burner. Position electrodes so tips are directly above burner port ports and about ." to 3/8" above burner. c. Check for 120V at each coil on the gas valve and listen for click, indicating gas valve is opening. If 120V present, but gas valve does not click, replace gas valve. Spark for six (6) seconds, main burner lights, but goes out when spark stops. Check for clean ground path between electrode bracket and fireplace chassis. Check wiring to wiring diagram label. Check for broken electrode on high-tension lead attachment to module. Clean, position according to wiring diagram, and repair defective electric connections. If all electrical connections are clean and correct, replace module. Main burner lights normally and then goes out. a. Check ignitor to burner gap. Igniter should be located 1/4" to 3/8" above burner area. b. Check high-tension lead and connector for shorts. Replace spark electrode assembly. c. Refer to installation instructions troubleshooting guide for issues such as venting. Repair as required. DIRECT IGNIT...

Questo manuale è adatto anche per i modelli :
Camini - BVD34FP30 (4.27 mb)
Camini - BVD34FP50 (4.27 mb)
Camini - L)N-1 (4.27 mb)
Camini - BVD36FP32 (4.27 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie