Log:
valutazioni - 4, GPA: 4 ( )

Istruzioni per l'uso Stovax, Modello SLBV-40NE

Produttore : Stovax
File Size : 2.89 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


ELECTRONIC IGNITION WIRING dIAGRAM _________ *Control switch options: ON/OFF wall switch, unit-mountable ON/OFF switch, or ON/OFF remote control system (see "Accessory Components" in the Care and Operation Instructions). TRANSFORMER 3V BROWN BROWN BLACK BATTERY BACK-UP BLACK (SENSOR) BLACK (IGNITER) IGNITER MODULE 3V RED PILOT INOUT VENT LO HI THTP TH TP IN ORANGE (THTP) BLACK (TP) GREEN (TH) HIGH LIMIT SWITCH Pilot Burner Pilot Tube Assembly Schematic Representation Only Electronic Gas Control Valve - DEXEN B-Vent appliances only -High limit switch must be factory installed as shown. If wires to this switch are replaced, wires must be Type AWM 200°C -18 gage wire ONLY. CONTROL SWITCH * UNIT MOUNTED ON/OFF SWITCH, IF SUPPLIED Junction Box J-Box Wiring BK W G CAV021* Control Switches: Wall On/Off or Remote Control Switch. Switch, Unit Mounted On/Off Switch NOTES: 1. If any of the original wire as supplied must be replaced, use Type AWM 105°C -18 gage wire ONLY. 2. 120 VAC, 60 Hz -Less than 3 Amps. CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. See Figure 14 for detailed drawing of junction box / receptacle wiring. Figure 13 Figure 14 J-BOX / RECEPTACLE WIRING 120V, 60HZ, 1PH Green Ground Screw Tab Intact GreenNeutral Side of Receptacle 120 VAC - Black Neutral - WhiteGround - Green Junction Box Field Wired Factory Wired Hot Side of Receptacle Black Tab Intact White J-BOX/RECEPTACLE WIRING 120V, 60Hz, 1PH SUPERIORSUPERIORB-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Step 5. [OPTIONAL] Install Outside Combustion Air Kit An optional outside combustion air kit (model FOAK-4, FOAK-4LD, or DK-4) may be used with these appliances (see "Installation Accessories," at right). Refer to the instructions included with the air kits for specific installation information. If used, the outside air kit must be installed before the fireplace is framed and enclosed in the finished wall. Outside air drawn into the fireplace supplies supplemental combustion air to the fire. Only one outside air duct is necessary, if installed. If additional length of duct is necessary, purchase locally available U.L. Class 0 or Class 1 metallic ducting. The duct may extend up to 50' (15.24 m) in one continuous piece. Note: When installing the air duct vertically, do NOT terminate the duct closer than 3' below the chimney top. Outside supplemental combustion air ducting may be run upward or vertically through framing and ceiling joists, with the hood installed through an outside wall and 3' (1 m) below the termination. Ducting may also be run downward through floor joists and under the home to a ventilated crawlspace not considered part of the living area of the home. Note: NEVER terminate an outside supplemental combustion air kit in attic space under any circumstances. After completing installation of the optional outside air vent sy...

Questo manuale è adatto anche per i modelli :
Camini - SLBV-35NE (2.89 mb)
Camini - SLBV-35NE (2.89 mb)
Camini - SLBV-35NE (2.89 mb)
Camini - SLBV-35NE (2.89 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie