Log:
valutazioni - 3, GPA: 5 ( )

Istruzioni per l'uso Napoleon Fireplaces, Modello SLBV-40NE

Produttore : Napoleon Fireplaces
File Size : 2.89 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


mmH J L M N P QK M Front View H L K J Q N P Top View Flue Outlet for B-Vent Connection: 35 Models = 4 in. (102 mm) 40 Models = 5 in. (127 mm) 9-1/4 in. (235 mm) 1/2 in. (13 mm) 1-5/8 in. (42 mm) Right Side View 9-1/2 in. (241 mm) Optional Electrical Inlet Knockout requiring a field-provided Junction Box (Either Side) ELECTRICAL INLET 2-3/4 in. x 2 in. (70 mm x 51 mm) COVER PLATE with KNOCKOUT (Right Side) 16 in. (406 mm) Hood Left Side View 5-7/8 in. (149 mm) *NOTE: It is recommended that gas be stubbed in from LEFT side only. 3 in. (76 mm) 9-1/2 in. (241 mm) GAS INLET KNOCKOUT* 7-3/8 in. (187 mm) Hood 7-1/8 in. (181 mm) 5-7/8 in. (149 mm) 3 in. (76 mm) 16 in. (406 mm) fIREPLACE SPECIfICATIONS Figure 8-2 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. SUPERIORSUPERIORB-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Step 2. Route the Gas Line Note: Route a 1/2" (13 mm) gas line to either side of the appliance (left side routing is shown in Figure 9 ). Gas lines must be routed, constructed, andmade of materials that are in strict accordance with local codes and regulations. All appliances are factory-equipped with a flex ible gas line connector and 1/2-inch shutoff valve. (See Step 6 on Page 15.) NOTE: Gas line can be routed to either side. Reverse this illustration if routing to right side. Also see Figures 8-1 and 8-2. Figure 9: Route Gas Line 3" (76 mm) Left Side Front Corner of Fireplace Framing 6-1/2" (152 mm) Pipe Coupling(Recommended) Proper Sizing of Gas Line Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code, NFPA 54 - latest edition (USA) or CAN/CSA-B149.1 - latest edition (Canada). Never use galvanized or plastic pipe. Gas lines must be routed, constructed and made of materials that are in strict accordance with local codes and regulations. IMPORTANT: It is critical that a licensed installer perform this step strictly per NFPA. We recommend that a qualified, licensed plumber or gas fitter be hired to correctly size and route the gas supply line to the appliance. Installingagassupplylinefromthefuelsupplyto theapplianceinvolvesnumerousconsiderations of materials, protection, sizing, locations, controls, pressure,sediment,andmore.Certainlyno one unfamiliar and unqualified should attempt sizing or installing gas piping. • All appliances are factory-equipped with a flexible gas line connector and 1/2 inch shutoff valve (see Figure 17 on Page 15). • See Massachusetts Requirements on Page 4 for additional requirements for installations in the state of Massachusetts in the USA. • The gas supply line should NOT be connected to the appliance until Step 6 on Page 15). • A pipe joint compound rated for gas should be used on the threaded joints. Ensure that propane-resistant compounds are used in propane applications. Be very careful that the pipe compound does not get inside the pipe. • It is recom...

Questo manuale è adatto anche per i modelli :
Camini - SLBV-35NE (2.89 mb)
Camini - SLBV-35NE (2.89 mb)
Camini - SLBV-35NE (2.89 mb)
Camini - SLBV-35NE (2.89 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie