Log:
valutazioni - 4, GPA: 4.5 ( )

Istruzioni per l'uso Monessen Hearth, Modello DT-400CMN

Produttore : Monessen Hearth
File Size : 973.7 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Orient the housing of the termination with the arrow pointed upwards. Secure the termination to the exterior wall. M. Install the desired termination - See the horizontal venting figures for application restrictions on the round termination (SV4.5HTR). 1. Install the square (SV4.5HTS) or short square termination (SV4.5HTSS) -For the last step , from outside the exterior wall, slide the collars of the termination into the adapter (see Figure 31) until the termination seats against the exterior wall surface to which it will be attached. Orient the housing of the termination with the arrow pointed upwards. Secure the termination to the exterior wall. The horizontal termination must not be recessed into the exterior wall or sidingby more than the 1 ..." (32 mm) as shown in Figure 31. Orient the housing of the termination with the arrow pointed upwards. Secure the termination to the exterior wall. The horizontal termination must not be recessed into the exterior wall or siding by more than the 1 ..." (32 mm) as shown in Figure 32. The SV4.5HTR Round Termination may not be used when the appliance is vented directly out the wall from the rear as shown in Figures 34 and 35. 2. Install the long square termination (SV4.5HTSSL) -For the last step , from outside the exterior wall, slide the collars of the termination onto the last vent section (seeFigure 32) until the termination seats against the exterior wall surface to which it will be attached. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 37-Top Vent - ONE 90 DEGREE ELBOW ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE Figure 38-Rear Vent - TWO 90 DEGREE ELBOWS Figure 36-Top Vent - ONE 90 DEGREE ELBOW -ELBOW CONNECTION AT APPLIANCE Refer to Table 3 on page 16 for an aid in venting component selection for a particular range of exterior wall thicknesses when using the square (SV4.5HTS), small square (SV4.5HTSS) or the round (SV4.5HTR) termination . Refer toTable 3 on page 16for an aid in venting component selection for a particular range of exterior wall thicknesses when using the square (SV4.5HTS), small square (SV4.5HTSS) or the round (SV4.5HTR) termination . Refer to Table 3 on page 16 for an aid in venting component selection for a particular range of exterior wall thicknesses when using the square (SV4.5HTS), small square (SV4.5HTSS) or the round (SV4.5HTR) termination . HORIZONTAL VENT FIGURES/TABLES (CONTINUED) Short Square Termination (SV4.5HTSS) shown; Long Square Termination (SV4.5HTSSL) may also be used; Square Termination (SV4.5HTS) may also be used Round Termination (SV4.5HTR) may also be used. Short Square Termination (SV4.5HTSS) shown; Long Square Termination (SV4.5HTSSL) may also be used; Square Termination (SV4.5HTS) may also be used Round Termination (SV4.5HTR) may also be used. Short Square Termination (SV4.5HTSS) shown; Long Square Termination (SV4.5HTSSL) may also be used; Square Termination (SV4.5HTS) may also be used Round Termination (SV4.5HTR) may also be used. ELBATF wobleeerged09en0=V .xaM)m419.0(teef3=H ELBATG muminiMV mumixaMH teef)m(teef)m( 1 )503.0(5 )25.1( 2 )16.0(01)1.3( 3 )419.0(51)56.4( 4 )22.1(02)2.6( .xaM)m4.21(teef04=H+V .xaM)m2.6(teef02=H HELBATmuminiMV mumixaMH H+H1 mumixaMteef)m(teef)m(teef)m( 1 )503.0(2 )016.0(5 )25.1( 2 )016.0(4 )22.1(01)1.3( 3 )419.0(6 )68.1(51)56.4( 4 )22.1(8 )84.2(02)2.6( H+H+V1 .xaM)m4.21(teef04= .xaM)m84.2(teef8=H H+H 1 .xaM)m2.6(teef02= H *Wall Firestop/Spacer (SV4.5HF) V *When using Secure Flex, use Wall Firestop/Spacer SV4.5HF. H V *Wall Firestop/Spacer(SV4.5HF) **Ceiling Firestop/Spacer(SV4.5BF) *When using Secure Flex, use Wall Firestop/SpacerSF4.5HF. **When using Secure Flex, use Ceiling Firestop/Spacer SF4.5BF. H1 V H *Wall Firestop/Spacer (SV4.5HF) **Ceil...

Questo manuale è adatto anche per i modelli :
Camini - DT-400CEP (973.7 kb)
Camini - DT-400CEN (973.7 kb)
Camini - DT-400CEP (973.7 kb)
Camini - DR-400CEN (973.7 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie