|
Facilità d'uso
Please check the contents of hardware kit against the corresponding model check list, prior to installation of the unit. See Fig. 1. CAUTION: Because the compressor is located on the controls side of the unit (left side), this side will be heavier and more awkward to manipulate. Inadequate support on control side of the unit can result in personal injury and damage to your unit and property. Therefore, it is recommended that you have someone assist you during the installation of this unit. NOTE: Your unit is designed to evaporate condensation under normal conditions. However, under extreme humidity conditions, excess condensation may cause basepan to overflow to the outside. The unit should be installed where condensation run-off cannot drip on pedestrains or neighboring properties 3/4” (19.1mm) screws (9) *Factory installedon some models Safety Lock (1) Adhesive Foam Seal(1) Sash bracket (2) “L” Shapedmountingbracket (1) INSTALLATION HARDWARE Side Curtain RH (1) Side Curtain LH (1) 3/8” (9.5mm) screws (4) (*Factory installed on some models) Fig. 1 3 INSTALLATION LOCATION A) This room air conditioner is designed to fit easily into a single or double hung window. However, since window designs vary, it may be necessary to make some modifications for safe, proper installation. B) Make sure window and frame are structurally sound and free from dry and rotted wood. C) For maximum efficiency, install the air conditioner on a side of the house or building which favours more shade than sunlight. If the unit is in direct sunlight, it is advisable to provide an awning over the unit. D) Provide sufficient clearance around the cabinet to allow for ample air circulation through the unit (See Fig. 2). The rear of the unit should be outdoors and not in a garage nor inside a building. Keep unit as far away as possible from obstacles/ obstructions and at least 30” above the floor or ground. Curtains and other objects within a room should be prevented from blocking the air flow. Be certain the proper electrical outlet is within reach of the installation. Use only a single outlet circuit rated at 15 amps. All wiring should be in accordance with local and national electrical codes. F) DO NOT install unit where leakage of combustible gas is suspected. Your air conditioner may fail to operate in air containing oils (including machine oils), sulfide gas, near hot springs, etc. Awning Fence, wall, or other obstacleGround Side Obstruction 20” Min 30” Min 20” Min 12” Min Fig. 2 INSTALLATION INSTRUCTIONS 1) Assembly of the Upper Channel to Cabinet. • “L” Shaped Top Channel: Install the “L” shaped channel to the top of the cabinet as shown in Fig. 3, using four (4) 3/8” screws. 2) Assembly of the Side Curtains to Cabinet. • Extend the shutter from the shutter frame and slide it into the shutter tabs on the side channel of the air conditioner, as shown in Fig. 4. • Slide the shutters into the top (“L” Shaped) and bottom (“U” Shaped) channels. The shutters are identified (on frame) as left and right. 3/8” screws “L” shapedmounting bracket “U” shaped Channel(Factory Installed)Fig. 3 Slide down into tabs Shutter tabs Shutter Shutter frame Fig. 4 4 INSTALLATION (cont’d) INSTALLATION INSTRUCTIONS (cont’d) 3) Completing the Installation • Cut the foam (non adhesive) sealing strip to fit the area of the window sill that the air conditioner will rest on. • Carefully place the air conditioner into the window with the “L” shaped mounting bracket (on top) positioned in front of the upper window sash. The bottom of the cabinet should be positioned on the “recessed” portion of the window frame. Pull the window down until it rests just behind the front flange of the (top) “L” shaped mounting bracket (See Fig. 5). • Expand the shutter frames (fully) on each side and secure the top of the frames to the window sash using one 3/4” screw on each side and one in the “L” shaped mounting bracket (Fig. 5). • Secure the shutter clamp on each side of the (lower) shutter and secure to window sill using one 3/4” screw on each side (Fig. 5). • Place the second foam sealing strip to fit the opening between the inside and outside windows, then attach the safety lock to the outside window frame using one 3/4” screw (See Fig. 6). Window sash “L” ShapedMountingBracket Shutter clamps 3/4” screws Fig. 5 Safety Lock 3/4” screw Foam Seal Fig. 6 PLEASE NOTE: Window applications come in a variety of different styles. Therefore, it may be necessary to modify or improvise your particular installation. 5 OPERATING INSTRUCTIONS KEY PAD FEATURES LED DISPLAY: Displays the following information independently;Set Temperature, Ambient RoomTemperature and Auto Timer On/Off settings. POWER: Turns unit On/Off. MODE: Allows you to scroll through and select the desired operating mode; Cool , Dry , Fan Only and *Auto .The selected mode will be denoted by the adjacent indicator light.*‘Auto’is a pre-set factory program that automatically defines the mode (Cool or Dry) and fan speed based o...
Questo manuale è adatto anche per i modelli :Condizionatori - DAC12010E (410.04 kb)
Condizionatori - DAC8010E (410.04 kb)