Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Panasonic, Modello HQ2051SH

Produttore : Panasonic
File Size : 879.57 kb
File Nome : HQ-2051SH.PDF

Lingua di insegnamento: enes

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


The seriousness is classified by the following indications. ■ Because of the weight of the product, it is recommended that you have a helper to assist in the installation. ■ Use Caution! Sharp Edges! See Warning, page 4. /K WARNING ! This is symbol indicates the possibility of death or serious injury. âs CAUTION ’ symk°' ¡ndicates the possibility of injury or damage to properties only. Meanings of symbols used in this manual are as shown below. Í® \ Be sure not do this. Be sure to follow the instructions. J > Otherwise, it will cause electric shock or fire due to heat generation. It will cause electric shock or fire due to heat generation. -( A WARNING [&G^(%Hnqp07QB36E) 1 It will cause electric shock or fire * It will cause electric shock or fire, due to heat generation. • If the power cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. *№ OîSCuIsXSa^CâDDD^QSïBSCbiÎte Q3I^P^GÎ?i3jû3(nïfîi • They are sharp and may cause an injury. ®3 (BS8(SpD^ffî© CŒffî oaîû^to^(n^(a?Efii^ te9zaffi(Mai0g№CE0 ÊSQDi " removed! • It could cause dust to accumulate on the heat exchanger. E© GEfiopî^QEfiËOûas It may cause an electric shock. StoQBB(SlÈaDffi©€fl? 'C№C!E23R) conditioner! * Water may enter the unit and degrade the insulation. It may cause an electric shock. tQ?GDSCS3 3DÈ© - This could injure the pets or plants. î^ssQêE^êgû insecticide • It may cause a fire or damage of the cabinet. №m®30O3lfi3 0002)0© CTrarrmfoFifU' 1 Since the fan rotates at high speed during operation, it may cause an injury. E©GEfi(!^(iteQ^toÊIïi7 "(m other. intended > Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc. WTbpJedgesl Use caution when handling the case. Grip it firmly and do not allow it to slip while holding it. Use heavy gloves to handle the case if necessary. Sharp edges About the Controls on the Air Conditioner The controls will look like one of the following: — Controls ■jjm C HIGH - r(A LOW» 1 1 )F F BBCT HIGH 1 1 • LOW * C h'C >F ^)Y§§ Off - Turns air conditioner off. High Fan - High speed fan operation without cooling. Low Fan - Low speed fan operation without cooling. High Cool - Cooling with high speed fan operation. Low Cool - Cooling with low speed fan operation. THER 5 /4 m \1X^ M( DSTAT TEMP C 1 V. :o NTROL 6v \ \ 8 ^ M —^ 10 This automatically controls the temperature of the indoor air. Turn the knob so that the arrow points to the larger marks for greater cooling. Point the arrow to the smaller marks for more moderate cooling. (i.e. the higher the number, the greater the cooling) ■ FOR NORMAL COOLING 1. Turn the operation switch to the High Cool or the Low Cool setting. 2. Set the thermostat control to the desired temperature mark f (the mid-point is a good starting position). If the room temperature is not satisfactory after a reasonable time, adjust the control to a cooler or warmer setting, as appropriate. ■ FOR MAXIMUM COOLING 1. Turn the operation switch tt> the High Cool setting. 2. Set the thermostat control to the largest x10 temperature mark. ■ FOR QUIETER OPERATION 1. Turn the operation switch to the Low Cool setting. 2. Set the thermostat control as needed. ■ CAUTION When the air conditioner has performed its cooling operation and is turned off or set to the fan position, wait at least 3 minutes before resetting to the cooling operation again. Additional controls and important information. — Air Direction • ADJUSTING THE AIR DIRECTION USING THE HORIZONTAL AIR-DEFLECTOR CONTROL Using the control tabs, the air flow can be directed to the left, right, straight ahead, or any combination of these directions. Care and Maintenance TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET. •TO CLEAN FILTER The air filter will become dirty as it removes dust from the inside air. It should be washed at least every 2 weeks. If the air filter remains full of dust, the air flow will decrease and the cooling capacity will be reduced, possibly damaging the unit. 1. Pull the inlet grille forward and pull out the air filter. (Fig. 1) 2. Wash the air filter in warm 104°F (40°C) water. Be sure to shake off all the water before replacing the filter. • CLEANING THE AIR CONDITIONER The front grille and inlet grille may be wiped with a cloth dampened in a mild detergent solution. (Fig. 2) The cabinet may be washed with mild soap or detergent and lukewarm water, then polished with a liquid wax used for appliances. To ensure continued peak efficiency, the condenser coils(outside of unit) should be checked periodically and cleaned if clogged with soot or dirt from the atmosphere. • HOW TO REMOVE THE FRONT GRILLE 1. Remove the thermosta...

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie