Produttore : APC
File Size : 309.8 kb
File Nome : 20091210-150547-ASTE-6ZHP5K_R0_EN.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


3. The Back-UPS will then indicate the current sensitivity, as shown in the Transfer Voltage and Sensitivity Adjustment table below. 4. To select the LOW sensitivity setting, press the ON/OFF push button until the LED begins flashing GREEN. 5. To select the MEDIUM sensitivity setting, press the ON/OFF push button until the LED begins flashing RED. 6. To select the HIGH sensitivity setting, press the ON/OFF push button until the LED begins flashing AMBER. 7. To exit Programming mode, once sensitivity is set, wait approximately 5 seconds, and all of the LED indicators will be off (unlit). Connect Equipment Transfer Voltage and Sensitivity Adjustment Indicators Flashing Sensitivity Setting Input Voltage Range (For Utility Operation) When to Use Green Flashing LOW 155 - 290 Input voltage is extremely low or high. Not recommended for computer loads. Red Flashing MEDIUM (factory default) 160 -280 Back-UPS frequently goes on battery. Amber Flashing HIGH 165 - 270 Connected equipment is sensitive to voltage fluctuations. Connect AC Line Cord Plug the Back-UPS power cord into a wall outlet, not a surge protector or power strip. The outlet should be near the equipment and easily accessible. 990-2994B Copyright 2007 American Power Conversion Corp. All other trademarks are property of their respective owners. Troubleshooting Use the table below to solve minor Back-UPS installation or operation problems. Consult APC Online Technical Support or call APC Technical Support for assistance with problems that cannot be resolved using the table below: Problem Probable Cause Solution Back-UPS will not turn on. No power at the Surge Protection Only outlets. Connected equipment loses power. The Power On indicator is lit, and the unit is beeping four times every 30 seconds, or it is emittng a constant tone. The Power On indicator flashes once persecond, and the Back-UPS beeps once persecond at the same time. Circuit Breaker has tripped. Battery is disconnected, or utility power is not available at the wall outlet. Surge Protection Only outlets are overloaded. Utility power not available at the wall outlet. The Back-UPS is overloaded. The Back-UPS has exhausted its available battery power. The equipment connected to the Back-UPS does not accept the step-approximated sine waveform from the unit. The Back-UPS may require service. The unit is using battery. Battery capacity is low (there is about 2 minutes of use remaining). Reduce the amount of equipment plugged into the “Battery Backup + Surge Protection” outlets. Reset the circuit breaker by pushing it back in. Ensure the fuse or circuit breaker for the wall outlet is okay, and the wall switch controlling the wall outlet (if any) is in the ON position. Reduce the number of devices plugged into Surge Protection Only outlets. Ensure the fuse or circuit breaker for the outlet is not tripped, and the wall switch that controls the outlet is ON. Ensure the equipment you want to stay powered during a power failure is plugged in...

Questo manuale è adatto anche per i modelli :
Jig Saw e - BACK-UPS BR650CI (309.8 kb)
Jig Saw e - BACK-UPS BR650CI (309.8 kb)
Jig Saw e - BACK-UPS BR650CI (309.8 kb)
Jig Saw e - BACK-UPS BR650CI-AS (309.8 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie