4. Audio Routing Settings Transmit and receive device bundle numbers must be properly matched in order to transfer audio data over a CobraNet network. 4-1. Transmit Bundle Settings 1 Select the MY16-CII in the Discovery window, and then select [Configure] from the [Tools] menu. Four transmit bundles and eight receive bundles will be shown in a list. 2 Double click transmit bundle number 1, or select it and then click [Configure]. 3 Enter an appropriate bundle number in the “Bundle” field. NOTE Enter a number that is not already used as a transmit bundle number anywhere else on the network. 4 Select the bit depth to be used for audio transfer from the “SubFormat” pull-down menu. Check the [All Same] checkbox to set all channels in the bundle, and all bundles for the device, to the same value. Bit depth only needs to be set for the transmitting device. No bit depth setting is required for the receiving device. When latency is set to 5.33 msecs and bit depth is set to 24 bits, the maximum number of channels that can be transmitted per bundle is limited to seven. In such cases set the SubCount field to “7”. Refer to the MY16-CII or DME8i-C/DME8o-C/DME4io-C owner’s manual for details on the relationship between bit depth and the number of channels that can be handled per bundle. 5 Click [Apply] and then [OK]. 4-2. Receive Bundle Settings 1 Select the DME4io-C (the receiving device) in the Discovery window, and then select [Configure] from the [Tools] window. 2 Select receive bundle number 1, and then click [Configure]. 3 Enter the same bundle number as set for the MY16-CII. The settings made thus far enable audio data transfer from the MY16-CII installed in the LS9-16 console to the DME4io-C satellite unit. The green indicators on the right side of the window shown above will appear when audio data is being properly received. 4 Click [Apply] and then [OK]. 5. Serial Bridge Settings The serial bridge settings described below allow asynchronous serial data communication between CobraNet devices. In this example serial bridging will be used to allow DME4io-C head amp gain control from the LS9-16 via the CobraNet network. Only the CobraNet Discovery settings will be discussed here. Refer to the LS9-16 and DME4io-C owner’s manuals for details on setting up those devices for remote head amp control. 5-1. Transmitting Device (MY16-CII) Settings 1 Select the MY16-CII in the Discovery window, and then select [Configure] from the [Tools] menu. 2 Click [Advanced]. The [Advanced Configuration] dialog box will appear. 3 Referring to the chart below, set the serial channel numbers in the SerialTxMAC (transmit) and SerialRxMAC (receive) fields so that they match. NOTE The SerialTxMAC and SerialRxMAC field values must be entered in MAC address format, corresponding to serial channels 1 through 15. Serial Channel SerialRxMAC SerialTxMAC OFF 01:60:2B:FF:88:AF 01:60:2B:FF:88:AE 1 01:60:2B:FF:88:81 2 01:60:2B:FF:88:82 3 01:60:2B:FF:88:83 4 01:60:2B:FF:88:84 5 01:60:2B:FF:88:85 6 01:60:2B:FF:88:86 7 01:60:2B:FF:88:87 8 01:60:2B:FF:88:88 9 01:60:2B:FF:88:89 10 01:60:2B:FF:88:8A 11 01:60:2B:FF:88:8B 12 01:60:2B:FF:88:8C 13 01:60:2B:FF:88:8D 14 01:60:2B:FF:88:8E 15 01:60:2B:FF:88:8F 4 Click [Apply] and then [OK]. In the example below, channel 2 is used for serial data transmission from the MY16-CII to the DME4io-C, and channel 1 is used for serial data transmission from the DME4io-C to the MY16-CII. 6. Other Settings 6.1. Conductor Priority Settings Conductor priority determines which network node functions as the conductor. Refer to the MY16-CII owner’s manual for information on CobraNet conductors and performers. It is normally not necessary to set conductor priority manually. Refer to the CobraNet Manager Lite for Yamaha owner’s manual for information on conditions that make manual setup necessary. 1 In the Discovery window, select [Preference] in the [Tools] menu. 2 Check the [Enable SNMP] checkbox. 3 Click [OK]. 4 Select the target device in the Discovery window, and select [Configure] from the [Tools] menu. 5 Click the [SNMP] button. The [Generic SNMP R/W] dialog box will appear. 6 Enter the following values in each field. . Type:Integ...
Questo manuale è adatto anche per i modelli :Strumenti Musicali - DME8i-C (1.15 mb)
Strumenti Musicali - DME8o-C (1.15 mb)