Log:
valutazioni - 2, GPA: 4 ( )

Istruzioni per l'uso Bosch, Modello HDS255U

Produttore : Bosch
File Size : 3.3 mb
File Nome :
Lingua di insegnamento: enesfr
Vai a scaricare



Facilità d'uso


Clearance from range top to adjacent vertical walls must be at least 4". Seal any openings in the wall behind the appliance and in the floor below the appliance. For the cabinets over the cooking surface and the adjacent cabinets, the maximum cabinet depth from back wall is 13 inches. The gas supply line and electrical outlet must be within the spaces indicated in Figure 2. The gas shut offvalve must also be accessible without moving the range. Instructions were determined using Standard American base cabinets measuring 36" high x 24" deep. If nonstandard cabinets are used, care should be taken to alter dimensions accordingly. NOTICE: Some cabinet finishes cannot survive the temperatures al lowed by U. L., particularly self-cleaning ovens; the cabinets may discolor or stain. This is most noticeable with laminated cabinets. 30" Minimum Centered 30' 4" Min. Min. a 18" 4" Min. No Clearance to Cabinet / Wall Required Min. Figure 1: Cabinet Preparation Figure 2: Gas Supply Line and Electrical Outlet Placement 3. 1. 2. 3. Install Anti-Tip Bracket Adjust height of range and level by rotating the adjustable leg supports on the bottom of the range, using 1-1/4" wrench. Measure to locate bracket position as shown in Figure 3. Secure bracket with 2 screws adequate for mounting surface, not included. (i.e.; for wood floor use wood screws for concrete floor use concrete anchors and screws.). Page 3 Step 4: Connect Electric 4. Connect Electric Ranges are dual rated for use on either 120/240 VAC or 120/208 VAC. See table for power ratings and circuit breaker sizes based upon the supply voltage for each mode (See chart below). VOLTS A.C. HZ RATING KW CIRCUIT BREAKER 120/240 60 12.1 30 AMPS 120/208 60 1 9. 25 AMPS CAUTION: make certain that gas shutoff valve and all burner controls are in OFF position before beginning. TO PREVENT ELECTRICAL SHOCK, THE GROUNDING PRONG SHOULD NOT, UNDER ANY CIRCUMSTANCES, BE CUT OR REMOVED. IT MUST BE PLUGGED INTO A MATCHING GROUNDING TYPE RECEPTACLE AND CONNECTED TO A CORRECTLY POLARIZED 240-V0LT CIRCUIT. A separate circuit is recommended which is in compliance with the NEC. If there is any doubt as to whether the wall receptacle is properly grounded, have it checked by a qualified electrician. This appliance may be connected to the power supply by installing flexible conduit or a power cord set. The electrical rating of the power cord set (not supplied) must be 240 volt, 30 amperes. The power cord set shall be marked "For Use with Ranges." The power supply shall be connected to the range terminal block compartment located near the bottom of the back panel (See Figure 4 , at right). It is accessible by removing the terminal block cover. Place strain relief in knockout below terminal block (See Figure 4 below). Feed range cord through hole and strain relief up to terminal block. Allow for slack in the cord between the strain releif and terminal block. Once cord length/ slack has been adjusted, attach strain relief per instructrions included with strain relief. Connect wiring as described below and on next page. C TIP ^ The knockout panel can be removed from the range to install the strain relief: Remove panel from range, install strain relief in panel and re-attach. > f The strain relief provided with your range cord I must be properly installed. Electrical Connection Procedures Refer to Figures 5-10 ( below and next page) for further explanation. WARNING CONSULT YOUR INSTRUCTIONS FOR 'ELECTRICAL CONNECTION PROCEDURES'. COPPER WIRE MUST BE USED FOR CONNECTION TO THE TERMINAL BLOCK. WHEN POWER SUPPLY CORD KIT IS USED TO CONNECT RANGE TO THE POWER SUPPLY. USE ONLY CORD KITS RATED 120/240 VOLTS MINIMUM AND MARKED FOR USE WITH RANGES. REFER TO INSTALLATION INSTRUCTIONS FOR PROPER CORD KIT AMPERAGE RATING, RISK OF FIRE OR ELECTRICAL SHOCK MAY BE INCURRED IF AN INCORRECT SIZE RANGE CORD KIT IS USED, THE INSTALLATION INSTRUCTIONS ARE NOT FOLLOWED, OR THE STRAIN RELIEF BRACKET IS DISCARDED. RISK OF ELECTRIC SHOCK FRAME GROUNDED TO NEUTRAL OF APPLIANCE THROUGH A LINK GROUNDING THROUGH THE NEUTRAL CONDUCTOR IS PROHIBITED FOR NEW BRANCH-CIRCUIT INSTALLATIONS, (1996 NEC) MOBILE HOMES AND RECREATIONAL VEHICLES, OR IN AN AREA WHERE LOCAL CODES PROHIBIT GROUNDING THROUGH NEUTRAL CONDUCTOR. FOR INSTALLATIONS WHERE GROUNDING THROUGH THE NEUTRAL CONDUCTOR IS PROHIBITED: (1) DISCONNECT THE LINK FROM THE NEUTRAL. (2) USE GROUNDING TERMINAL OR LEAD TO GROUND UNIT: AND (3) CONNECT NEUTRAL TERMINAL OR LEAD TO BRANCH CIRCUIT NEUTRAL IN USUAL MANNER (WHEN THE APPLIANCE IS CONNECTED BY MEANS OF A CORD KIT, USE 4 CONDUCTOR CORD FOR THIS PURPOSE). Center or white wire must always be attached to the central terminal on block. All screw and nut connections must be tight. 3-WIRE HOOK UP 1Ш0Щ101Й1 4-WIRE HOOK UP Remove ground strap from terminal block. Install with care, the green ground wire as shown at left. Attach ground wire and strap with screw provided with strap. F...

Questo manuale è adatto anche per i modelli :
Piastra - HDS252U (3.3 mb)
Piastra - HDS256U (3.3 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie