Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso Cleveland Range, Modello (T) MKDL-80-T (-CC)

Produttore : Cleveland Range
File Size : 2.11 mb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


We do however provide the following chart as a guide line for inspection and maintenance to keep your unit functioning at 100%. MONTHLY INSPECTIONS Item Inspection Item Switches Product Drain Valves Tangent Draw-Off Valve Butterfly Valve. Air Valve Inspect switches for damage and correct operation. Replace as required. Inspect parts for damage. Test valve for leakage. Replace as required. Inspect parts for damage. Test valve for leakage. Replace as required. Inspect parts for damage. Test valve for leakage. Check valve seals for air leakage. Inspect supply hose and fittings. Replace as required. Inspect air filter and replace if required. SIX MONTH MAINTENANCE Lubrication Grease trunnion housings. Grease bridge swivel assembly. Use "Never Seize" on tilt worm and gear. Strainers Clean strainers in steam in and cooling water supply lines. YEARLY MAINTENANCE Lubrication Drain hydraulic oil and remove filter. Replace oil and filter (see Hydraulic Oil Replacement Procedure. Solenoid Valves Inspect solenoid valves for proper operation. Clean or replace as required. WARRANTY Our Company supports a worldwide network of Maintenance and Repair Centers. Contact your nearest Maintenance and Repair Centre for replacement parts, service, or information regarding the proper maintenance and repair of your cooking equipment In order to preserve the various agency safety certification (UL, NSF, ASME/Ntl. Bd., etc.), only factory-supplied replacement parts should be used. The use of other than factory supplied replacement parts will void warranty. AIR LINE LUBRICATOR OIL FILLING PROCEDURE 1. Disconnect air supply and bleed system. 2. Remove cover on console (see PARTS LIST PNEUMATIC COMPONENTS). 3. Check for oiler location. AUTOMATIC DUMP VALVE Replacing “O” rings (8): Filler Cap Bowl 4. Inspect oil level in bowl. 5. Remove filler cap. 6. Add mineral oil as required. 7. Replace filler cap and console cover. Oiler AIR FILTER REPLACEMENT PROCEDURE 1. Disconnect air supply and bleed system. 2. Remove cover on console (see Parts List -Pneumatic Components). 3. Check for filter location. Deflector-/" Filter Element. Baffle- Lever- Bowl/Guard Assembly- 4. Push lever down and rotate bowl/ guard assembly 1/8 turn. 5. Push down on bowl/guard assembly and remove. 6. Unscrew baffle and remove filter element, inspect and replace filter if required. 7. Replace filler cap and cover. 1. Disassemble valve as per daily cleaning instructions. 2. Holding lower valve body (6), unscrew valve bottom (7). 3. Pull lower valve body out from cylinder body. 4. Replace "O" rings (8), as required. 5. Coat cylinder body and "O" rings with cooking oil or food-safe grease. 6. Reassemble. STEAM TRAP Each kettle is equipped with a steam trap in the line of the kettle outlet to the drain, to remove line condensate that forms inside the steam jacket. A good steam trap at startup releases air and wet steam into the drain line for a few minutes, then holds the steam jacket. During cooking, the trap periodically releases accumulated condensate. If the kettle's cooking performance becomes inadequate after long use, replacement of the steam trap with a new one may restore kettle operation to peak efficiency. Air Filter RE-INSTALLING SPEED CONTROL CABLE HYDRAULIC OIL REPLACEMENT PROCEDURE 1. Turn sprocket of speed control so that wire."A" is fully extended towards shaft "B". 2. Insert end of cable through bracket "C". 3. Insert wire so it protrudes approximately 1/2" to 5/8" through hole in bolt "D". Tighten bolt and bend end of wire. 4. Bring pump arm "E" up until it hits stop bolt "F" and tighten screw "C". 5. Reassemble unit. Speed control knob will go on pointing toward minimum setting. 6. Turn mixer on with speed control set at minimum setting. 7. If scraper arm is turning, loosen nut "G" and back stop bolt "F" off a few turns. Next loosen screw "C" and slowly pull up cable until scraper arm stops turning. Retighten screw "C". Gently turn stop bolt "F" down until it hits arm. Lock in place by tightening nut "G". 8. Scraper arm should now go from no rotation to fast rotation by turning speed control knob. One of the most important maintenance tasks is to change the hydraulic oil yearly. Under heavy usage the oil should be changed every nine months. It is important to change the oil regularly to prevent its breakdown which leads to the damaging of components. The oil filter should be changed at the same time as the hydraulic oil. A clean filter prevents particles from damaging the other components in the system. Replace the hydraulic fluid as follows: ^ Disconnect power to unit. ^ Remover the front top panel on the main console. ^ Remove chrome vent cap from breather pipe located beside electric motor. ^ Remove plug bolt from bottom left front corner of main console to drain oil into your catch pail. ^ Remove oil filter. ^ Replace plug bolt. ^ Refill unit through breather pipe using appr...

Questo manuale è adatto anche per i modelli :
Altri elettrodomestici da cucina - (T) MKDL-100-T (-CC) (2.11 mb)
Altri elettrodomestici da cucina - (T) MKDL-125-T (-CC) (2.11 mb)
Altri elettrodomestici da cucina - (T) MKDL-150-T (-CC) (2.11 mb)
Altri elettrodomestici da cucina - (T) MKDL-40-T (-CC) (2.11 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie