Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso TOA Electronics, Modello B-40REP

Produttore : TOA Electronics
File Size : 1.55 mb
File Nome : bf0bdab4-cfe9-4d34-a08d-8dab18eb0836.pdf

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


Toggle the switch from ON to OFF to operate the main burner from ON to OFF. 2. When lit for the first time, this appliance will emit a slight odor for an hour or two. This is due to the “burn-in” of internal paints and lubricants used in the manufacturing process. 3. Keep lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is important that control compartments, burners and circulating air passageways of the appliance be kept clean. The actuator for combustion air system is standard on all appliances but must not be operated if the complete system is not installed. Refer to Figures 5 and 6. When the complete outside combustion air vent system is installed, the installer will remove the actuator locking screw. Combustion Air Actuator Remove Locking Screwand “Pop” Actuator to the Left Before Initial Use NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. MANUALLY-RESET BLOCKED FLUE SAFETY SWITCH This appliance is equipped with a manually- reset blocked flue safety switch. Refer to Figure 7 for its location. If during appliance operation, the flame goes out (independently of the burner on/off wall switch), it may be due to the operation of this safety limit switch. First allow the appliance to cool. Then reset the safety switch by pushing the red reset button on the back of the switch. To access the blocked flue safety switch, remove the limit switch bracket, with switch and low voltage wires attached. Push the red reset button and then reinstall limit switch bracket. The appliance should then relight and remain lit. If this does not occur, turn off the appli- ance and call a qualified service technician. Figure 7 Manual Reset Limit Switch Lintel Extension Limit Switch Bracket Bracket Screw Maintenance The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service technician. Proper maintenance and use will require more frequent, less extensive inspections and servicing by the homeowner. Generally, annual inspections should be performed by a qualified service technician. More frequent periodic inspections and cleanings should be performed by the homeowner. Any discrepancies discovered by the homeowner should result in a call to a qualified service technician to effect the repair or correction. Refer to the maintenance schedule for maintenance tasks, procedures, periodicity and by whom they should be performed. IMPORTANT: TURN OFF GAS AND ANY ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. Pull Forward to Open, Push Back to Close Figure 6 If your screw is not removed and you have reason to believe that you have a complete outside combustion system, contact your distributor to have your appliance inspected for the presence of the complete system. DO NOT assume that you have this system in place because you have an actuating lever present on your appliance front face. WARNING: DO NOT OPERATE THE COMBUSTION AIR ACTUATOR UNLESS A COMPLETE OUTSIDE COMBUSTION AIR VENT SYSTEM HAS BEEN INSTALLED WITH YOUR APPLIANCE. To provide outside combustion air to your appliance while it is in operation, locate the combustion air actuator along the right side of the appliance opening (refer to Figure 5). To operate, push the end of the actuator to the left as shown in Figure 6, until it "pops" free of its "locked" position. Pull the actuator forward to open the combustion air door, and push it back to close. To "lock" the combustion air door closed, ensure the actuator is pushed all the way back, then push the end of the actuators to the right until the step in the actuator moves behind the appliance front face within the slotted opening. Millivolt Appliance Checkout The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. The top ..." (9 mm) at the pilot generator (thermopile) should be engulfed in the pilot flame. The flame should project 1" (25 mm) beyond the hood at all three ports (Figure 8 ). Electronic Appliance Checkout Light the burner, refer to the Lightilng Instructions in this manual. Ensure the ignitor lights the pilot. The pilot flame should engulf the flame rod as shown in Figure 8. With proper care and maintenance, your appliance will provide many years of enjoyment. If you should experience any problem, first refer to the trouble shooting guide in this manual. If problem persists, contact your Superior distributor. MILLIVOLT Hood Ignitor Rod ..." Min (9 mm) Pilot Nozzels Thermopile ELECTRONIC 3/8 To 1/2 Inch(9 mm to 13 mm) Figure 8 Proper FlameAdjustment Igniter Ground Pilot Nozzle Flame Sensor Electrode Hot Surface Figure 9 Log Placement WARNING: LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OFF. HANDLE ONLY WHEN LOGS ARE COOL. TURN OFF ALL ELECTRICITY TO THE APPLIANCE BEFORE YOU INSTALL GRATE AND LOGS. WARNING: THIS APP...

Questo manuale è adatto anche per i modelli :
Altri accessori per la casa - B-40REN (1.55 mb)
Altri accessori per la casa - B-40RMN (1.55 mb)
Altri accessori per la casa - B-40RMP (1.55 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie