Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso Philips, Modello SPO2 M1193A

Produttore : Philips
File Size : 2 mb
File Nome :
Lingua di insegnamento: ruplsvitentresfrdebgetslnlhuptskdaficslvltro
Vai a scaricare



Facilità d'uso


Do not position probe on cartilage or pressed against the head. 3 Plug sensor into instrument (or into adapter cable if needed). 4 Inspect and change the sensor application site periodically. 7 Cleaning and Low-Level Disinfection The reusable sensors should be cleaned and disinfected, but never sterilized. Follow the procedure outlined below. Warnings • Use only validated cleaning agents and disinfectants listed below; do not use any others. Failure to do so may damage the sensor or its connecting wires and shorten product lifetime or cause safety hazards. • Select disinfectants carefully as some have very similar names but completely different compositions. • Do not immerse the sensor connector in any of the cleaning solutions, disinfectant, or other liquid (only the sensor and cable housing may be immersed, not the connector). • Do not soak sensors in disinfectants longer than specified by the disinfectant manufacturer. • Do not sterilize the sensors. Validated Cleaning Agents - Mild Detergent -Salt Solution (1%) Validated Disinfectants Metricide® 28 Cidex® Formula 7 Kohrsolin® (2%) Metricide® Plus 30 Cidex® OPA Mucapur®-CD (1%) Terralin® Liquid Cidex® Plus Isopropanol (70%) or Isopropanol Wipe (70%) Incidin® Liquid Omnicide® 28 Step Cleaning and Low-Level Disinfection 1 Clean sensor following instructions supplied with cleaning agent. 2 Disinfect sensor following instructions supplied with disinfectant. 3 Rinse sensor in water, wiping it dry with a clean cloth, leaving to dry completely. If you notice any deterioration or damage to sensor or cable, dispose the sensor immediately. 8 Specifications Sensor Accuracy A-Series Sensors: For A-Series sensor SpO2 and Pulse Rate accuracy specifications, reference your Philips/Agilent/HP instrument’s Instructions for Use. B-Series Sensors: SpO2 and Pulse Rate accuracy specifications for M1191B and M1191BL sensors are the same as indicated for M1191A and M1191AL sensors in your Philips/Agilent/HP instrument’s Instructions for Use. Special Edition A-Series Sensors (AN-Series): SpO2 accuracy (functional saturation) for Special Edition A-Series sensors used in combination with M1020B or M3001A, Option A02, specified as the root-mean-square (RMS) difference between the measured values and the reference values, in the range 70 to 100% is: 2% for M1191ANL and M1192AN; 3% for M1193AN, M1194AN, and M1195AN. Neonatal Applications: The claimed accuracy numbers for neonatal application are already increased by an additional 1% to account for affect on oximeter measurements due to fetal hemoglobin in neonatal blood, as predicted by the literature. Light Emitting Diode Wavelength Ranges Wavelength ranges for the light emitting diodes used in these sensors are within 600nm-1000nm, with an optical output power of less than 15mW. Knowing the wavelength range can be useful to clinicians performing photodynamic therapy. Measurement Validation The SpO2 accuracy has been validated in human studies against arterial blood samp...

Questo manuale è adatto anche per i modelli :
Altri strumenti - SPO2 M1191A (2 mb)
Altri strumenti - SPO2 M1191AL (2 mb)
Altri strumenti - SPO2 M1191ANL (2 mb)
Altri strumenti - SPO2 M1191B (2 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie