Log:
valutazioni - 2, GPA: 4 ( )

Istruzioni per l'uso Philips, Modello SPO2 M1191ANL

Produttore : Philips
File Size : 2 mb
File Nome :
Lingua di insegnamento: ruplsvitentresfrdebgetslnlhuptskdaficslvltro
Vai a scaricare



Facilità d'uso


2These sensors extend compatibility to Philips brand OxiMax® compatible instruments. 3Preferred application sites for M1193A and M1195A sensors. 1 Intended Use Philips reusable SpO2 sensors are for multi-patient use, when continuous non-invasive arterial oxygen saturation and pulse rate monitoring are required. Accessories Supplied with Sensors • M1627A Adult Wristband: Supplied only with adult finger sensors to secure sensor cable to back of adult patient’s hand and wrist. • Instructions for Use: Describes sensor models, patient applications, Warnings against improper use, and specifications. Accessories Available for Separate Purchase • M1940A Adapter Cable: 8-pin (round female) to 12-pin (round male) adapter cable. Adapts 8-pin sensor connector to 12-pin instrument jack. Extends sensor cable length by 2m. DO NOT USE with M1191AL, M1191ANL, M1191BL sensors. • M1941A Extension Cable: 8-pin (round female) to 8-pin (round male) extension cable. Extends sensor cable length by 2m. DO NOT USE with M1191AL, M1191ANL, M1191BL sensors. Definition of Product Symbols Adult Pediatric Adult Finger Infant/Neo Hand Adult/Pediatric Ear Infant Neonate (Neo) Pediatric/Infant Finger Infant Toe Infant/Neo Foot Caution, See Documentation Prescription Use Only Storage Temp Contains no Latex 2 Warnings • These sensors are for use only with Philips/Agilent/HP instruments. Before using, verify the combination of instrument/sensor is specified in the instrument’s user documentation (e.g. Instructions for Use); otherwise patient injury may result. • Pulse oximetry measurements are statistically distributed. Two-thirds of all pulse oximetry measurements can be expected to fall within the stated accuracy (refer to Specifications later in this IFU for stated sensor accuracy). • Connect the sensor only to the SpO2 connection or the SpO2 adapter cable of the oximeter. • Do not reuse the sensor on a different patient until it has been disinfected. The sensor can be reused on the same patient for the patient’s entire stay. • At elevated ambient temperatures, patient skin could be severely burned after prolonged sensor application at sites that are not well perfused. To prevent this condition, be sure to check patient application sites frequently. All listed sensors operate without risk of exceeding 41o C on the skin if the initial skin temperature does not exceed 35o C. • Be sure to apply the sensor to the patient at the preferred or alternative application site, while following application instructions provided later in this document. Failure to do so can cause inaccurate measurements. • To avoid venous pulsation, obstructed circulation, pressure marks, pressure necrosis, artifacts and inaccurate measurements, make sure you are using a sensor of the correct size and that the sensor is not too tight. If the sensor is too tight, because the application site is too large or becomes too large due to edema, the excessive pressure applied may result in venous congestion distal from ...

Questo manuale è adatto anche per i modelli :
Altri strumenti - SPO2 M1191A (2 mb)
Altri strumenti - SPO2 M1191AL (2 mb)
Altri strumenti - SPO2 M1191B (2 mb)
Altri strumenti - SPO2 M1191BL (2 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie